Harman Kardon AVR 140 (serv.man2) EMC - CB Certificate ▷ View online
- Page 2 of 7 -
Order No. 46230
SUMMARY OF TESTING:
The apparatus complies with the requirements in IEC 60065:1998 and EN 60065:1998 with the following remarks.
This appendix test report, 46230 is covering the added variant model, AVR 140/230.
The model, AVR 140/230 is identical to earlier certified model AVR 135/230 except for equipped transformer type.
New transformer type, KLT5V037YE / CLT5V037YE and KLT5J033YE / CLT5J033YE for model AVR 140/130
have different thermel fuse type with previous one (see list of critical components), but equal to the previous models
in safety point of view, no additional tests is necessary.
have different thermel fuse type with previous one (see list of critical components), but equal to the previous models
in safety point of view, no additional tests is necessary.
This appendix test report 46230, must always be presented together with the main test report 34019.
Clause Information/Remarks
Comments
- Page 3 of 7 -
Order No. 46230
5
MARKING AND INSTRUCTIONS
P
Copy of the markings (continued) :
Comprehensible and easily
discernible
discernible
On front and rear side of the enclosure
P
Permanent durability against water
and petroleum spirit
and petroleum spirit
Tested with water / spirit
P
5.1
Identification, maker, model
P
Class II symbol
N
Rated supply voltage and symbol
AC-symbol (
~
) and
230V
P
Rated mains frequency
50Hz
P
Rated current or power
consumption
consumption
300W
P
- Page 4 of 7 -
Order No. 46230
LIST OF CRITICAL COMPONENTS
P
Part No
Component/
Object
Object
Manufacturer
Type / Model
Ratings /
Technical Data
Technical Data
Complies
with the
following
standard
with the
following
standard
Marks of
conformity
granted **
conformity
granted **
For
CENELEC
Countries
CENELEC
Countries
Mains plug
with cord
with cord
Kenic Electric Mfg.
KE-21
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
Kenic Electric Mfg.
KE-32
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt. Phino
Electrical
Wire & Cable
PHP-205
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
Kuk Je Tong shin
KKJ-1004A
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
Volex (Asia) Pte.
Ltd.
Ltd.
M4206
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
HWAJIN KDK Co.
KKP-419C
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
For U.K.
Mains plug
with cord
with cord
PHINO Electronics
Co., Ltd
Co., Ltd
PHP-307F
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
Volex (Asia) Pte Ltd.
MP5004A
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
Volex (Asia) Pte Ltd.
MP5005
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
Winbo Industries
MS 323N
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt. Luen
Tai
(IP’S)
Elect.
Kenic Electric Mfg.
9518
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
Well Shin Enterprise
Co. Ltd.
Co. Ltd.
WS-012A
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
OL91 Mains
Socket-outlet
Dae Ryung
Electronics.
Electronics.
A3-04-D007 2.5A/250V IEC60884-1
NEMKO
SW1
Mains switch POSTEC Electric. SDL1P-B
5A/80A
250V IEC60065
IEC61058-1
VDE
RY94
Mains relay
Tyco Electronics
SDT-S-112DMR
8A/120A 250V
IEC60065
IEC61058-1
IEC61058-1
SEMKO
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998
Click on the first or last page to see other AVR 140 (serv.man2) service manuals if exist.