Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-140-sm2.pdf
Date

Harman Kardon AVR 140 (serv.man2) EMC - CB Certificate ▷ View online

- Page 2 of 7 - 
 
 
 
 
                     
Order No. 46230 
 
 
 
SUMMARY OF TESTING:
 
 
The apparatus complies with the requirements in IEC 60065:1998 and EN 60065:1998 with the following remarks. 
 
 
This appendix test report, 46230 is covering the added variant model, AVR 140/230.
 
The model, AVR 140/230 is identical to earlier certified model AVR 135/230 except for equipped transformer type. 
New transformer type, KLT5V037YE / CLT5V037YE and KLT5J033YE / CLT5J033YE for model AVR 140/130 
have different thermel fuse type with previous one (see list of critical components), but equal to the previous models
in safety point of view, no additional tests is necessary.   
This appendix test report 46230, must always be presented together with the main test report 34019
 
 
Clause Information/Remarks 
Comments 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
- Page 3 of 7 - 
 
 
 
 
                     
Order No. 46230 
 
 
 
MARKING AND INSTRUCTIONS 
 
 
Copy of the markings (continued) :
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Comprehensible and easily 
discernible  
On front and rear side of the enclosure 
 
Permanent durability against water 
and petroleum spirit   
Tested with water / spirit 
 
5.1 
Identification, maker, model   
 
 
Class II symbol   
 
 
Rated supply voltage and symbol    
AC-symbol ( 
~
 ) and 
230V 
 
Rated mains frequency 
50Hz 
 
Rated current or power 
consumption  
300W 
 
- Page 4 of 7 - 
 
 
 
 
                     
Order No. 46230 
 
 
 
 
LIST OF CRITICAL COMPONENTS 
 
Part No 
Component/ 
Object 
Manufacturer 
Type / Model 
Ratings / 
Technical Data 
Complies 
with the 
following 
standard 
Marks of 
conformity 
granted ** 
For 
CENELEC 
Countries 
Mains plug   
with cord   
Kenic Electric Mfg. 
KE-21 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
 
alt. 
Kenic Electric Mfg. 
KE-32 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
 
alt. Phino 
Electrical 
Wire & Cable 
PHP-205 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
 
alt. 
Kuk Je Tong shin 
KKJ-1004A 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
 
alt. 
Volex (Asia) Pte. 
Ltd. 
M4206 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
 
alt. 
HWAJIN KDK Co. 
KKP-419C 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
For U.K. 
Mains plug 
with cord 
PHINO Electronics 
Co., Ltd 
PHP-307F 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
 
alt. 
Volex (Asia) Pte Ltd.
MP5004A 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
 
alt. 
Volex (Asia) Pte Ltd.
MP5005 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
 
alt. 
Winbo Industries 
MS 323N 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
 
alt. Luen 
Tai 
(IP’S)
 
Elect.
Kenic Electric Mfg. 
9518 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
 
alt. 
Well Shin Enterprise 
Co. Ltd. 
WS-012A 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
OL91 Mains 
Socket-outlet 
Dae Ryung 
Electronics. 
A3-04-D007 2.5A/250V  IEC60884-1
NEMKO 
SW1 
Mains switch  POSTEC Electric. SDL1P-B 
5A/80A 
250V IEC60065
 
IEC61058-1
VDE 
RY94 
Mains relay 
Tyco Electronics 
SDT-S-112DMR
8A/120A 250V 
IEC60065 
IEC61058-1
SEMKO 
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998 
Page of 15
Display