DOWNLOAD Harman Kardon AURA (serv.man6) Service Manual ↓ Size: 1.37 MB | Pages: 45 in PDF or view online for FREE

Model
AURA (serv.man6)
Pages
45
Size
1.37 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
aura-sm6.pdf
Date

Harman Kardon AURA (serv.man6) EMC - CB Certificate ▷ View online

Report No.: EM201300550-12                        Application No.: ZJ00032797                        Page 5 of 45 
 
 
2. GENERAL DESCRIPTION OF EUT 
2.1 APPLICANT 
Name: 
Harman International Industries, Incorporated 
Address: 
8500 Balboa Blvd, Northridge, CA 91329, United States 
2.2 MANUFACTURER 
Name: 
Harman International Industries, Incorporated 
Address: 
8500 Balboa Blvd, Northridge, CA 91329, United States 
2.1 BASIC DESCRIPTION OF EQUIPMENT UNDER TEST  
Equipment: 
Wireless stereo speaker 
Model No.: 
HARMAN KARDON AURA 
Adding Model 
Trade Name: 
HARMAN/KARDON 
Power supply 
 
AC Adapter: 
Adaptor input 100-240V~50/60Hz 1.5A Max output DC19V,3A  Speaker 
input: DC 19V,3A 
Frequency 
Range: 
2412MHZ~ 2472MHz 
Modulation type:  DSSS(802.11b)OFDM(802.11g) 
Channel space: 
5MHz  
Antenna type: 
PCB antenna 
Max antenna 
gain: 
4.80dBi 
Note: 
Pretest the two antenna port (con1 and con2). Found that antenna gain of 
con1 is 3.04dBi, antenna gain of con2 is 4.80dBi and con2 is worst port. So 
we record con2 port data. 
2.2 TEST OPERATION MODES 
Test mode: 
TX mode: EUT continue transmitting in lowest, middle and highest channels. 
RX mode: EUT is receiving in lowest and middle channels. 
2.3 LOCAL SUPPORTIVE INSTRUMENTS 
Name of Equipment 
Manufacturer 
Model 
Serial Number 
Notebook Lenovo 
E46A 
EB24320428 
 
Report No.: EM201300550-12                        Application No.: ZJ00032797                        Page 6 of 45 
 
 
3. LABORATORY AND ACCREDITATIONS  
3.1 LABORATORY 
The tests and measurements refer to this report were performed by EMC Laboratory of 
Guangzhou GRG Metrology and Test CO., LTD. 
         Add. 
  :    163 Pingyun Rd, West of Huangpu Ave, Guangzhou, 510656, P. R. China 
         Telephone:   +86-20-38699959, 38699960, 38699961 
Fax 
  :   +86-20-38695185 
3.2 ACCREDITATIONS 
Our laboratories are accredited and approved by the following approval agencies according to 
ISO/IEC 17025. 
USA 
FCC Listed Lab (No. 688188) 
China 
CNAS (No.L0446) 
China 
DILAC (No.DL175) 
Canada 
Registration No.:8355A-1 
3.3 MEASUREMENT UNCERTAINTY 
Measurement 
Frequency 
Uncertainty 
Radiated 
Emission 
Horizontal 
30MHz~1000MHz 4.2dB 
1GHz~12.75GHz 4.2dB 
Vertical 
30MHz~1000MHz 4.4dB 
1GHz~12.75GHz 4.4dB 
This uncertainty represents an expanded uncertainty factor of k =2. 
Report No.: EM201300550-12                        Application No.: ZJ00032797                        Page 7 of 45 
 
 
 
3.4 LIST OF USED TEST EQUIPMENT AT GRGT 
Name of Equipment 
Manufacturer 
Model 
Serial 
Number 
Calibration 
Due 
Maximum transmit power 
Power meter 
Agilent 
N1914 
MY53160018  2014-07-25 
Power sensor 
Agilent 
E9034 
MY53100025  2014-07-25 
Temperature& 
humidity chamber 
CEPREI CEEC-MSJ-60BE 11015 
2014-05-21 
AC power supply 
WEST 
WE-1120 
681598 
2014-05-31 
Shielding room 
ETS 
RFD_100 
3728 
2014-03-25 
Frequency Range 
Receiver R&S 
ESU40 
100106 
2014-01-24 
Temperature& 
humidity chamber 
ETOMN NTH1000-40A 
08100012 
2014-05-21 
AC power supply 
WEST 
WE-1120 
681598 
2014-05-31 
Dwell Time 
Receiver R&S 
ESU40 
100106 
2014-01-24 
Hopping channel separation 
Receiver R&S 
ESU40 
100106 
2014-01-24 
Hopping sequence 
Receiver R&S 
ESU40 
100106 
2014-01-24 
Spurious Emission from Tx/ Rx 
Biconical 
Log-periodic Antenna 
ETS.LINDGREN 3142C 
00075971 
2014-05-26 
Signal Generator 
R&S 
SML03 
103002 
2013-11-13 
Receiver R&S 
ESU40 
100106 
2014-01-24 
Biconical antenna 
ELECTRO-METRICS  BIA-30S 
166 
2014-05-26 
log-periodical antenna  ELECTRO-METRICS LPA-30 
383 
2014-05-26 
Horn antenna 
ETS.LINDGREN 
3117 
00075824 
2014-08-19 
Horn antenna 
SCHWARZBECK 
BBHA9120D 
D752 
2014-10-14 
Temperature and 
Humidity box 
CEPREI CEEC-MSJ-60BE 11015 
2014-05-21 
AC power supply 
WEST 
WE-1120 
681598 
2014-05-31 
 
Report No.: EM201300550-12                        Application No.: ZJ00032797                        Page 8 of 45 
 
 
4. RADIO TECHNICAL REQUIREMENTS SPECIFICATION 
4.1 MAXIMUM TRANSMIT POWER 
4.1.1  LIMITS 
Frequency 
EN300 328 clause 4.3.1 
2400MHz~2483.5 MHz 
20 dBm (i.e. 100mW) 
4.1.2  TEST METHOD 
EUT operation status: 
Keep EUT on transmitting mode by the software provided by 
manufacturer. 
Pretest the EUT at different transmission rate and report show 
the worst case data. 
     
Test channel: 
802.11b/g: 
Lowest channel: (2412MHz),Middle channel: (2442MHz), 
Highest channel: (2472MHz) 
Test condition: 
Normal and extreme test conditions. 
Test equipment used: 
Refer to section 3.4 
Test procedure: 
As 5.7.2.2 and annex C1 of standard EN 300328 
Remark:    
Pre-scan all the rate, found that:  
11Mbps of rate is the worst case of 802.11b;  
54Mbps of rate is the worst case of 802.11g ; 
 
4.1.3  TEST SETUP 
 
Attenuator 
 EUT     
Antenna 
connector  
Power meter 
Page of 45
Display

Click on the first or last page to see other AURA (serv.man6) service manuals if exist.