DOWNLOAD Sony SLV-L44AR / SLV-L66HFAR Service Manual ↓ Size: 6.28 MB | Pages: 68 in PDF or view online for FREE

Model
SLV-L44AR SLV-L66HFAR
Pages
68
Size
6.28 MB
Type
PDF
Document
Service Manual
Brand
Device
VCR
File
slv-l44ar-slv-l66hfar.pdf
Date

Sony SLV-L44AR / SLV-L66HFAR Service Manual ▷ View online

6-5
VP-1 PWB Assembly
TP183
(SW-P)
TP182
(ENV.)
Fig. 2-1-2
Note:
• Self-recording means “Record any broadcasting or video
signal and play back the just-recorded portion.”
2-1-3. SWITCHING POSITION ADJ.
Measuring Point
Measuring Equipment
Adj. Condition
 TP101
  Oscilloscope
PLAY mode
 (VIDEO OUT)
Alignment tape
 TP183 (SW-P)
(MH-2)
Adj. Location
Adj. Value
VR351 (SW-P)
6.5 H 
±
 0.5 H
T = 6.5H 
±
 0.5H
0.5H
1H
Rise
RF. SW. PULSE
Front edge of
vertical sync signal
Fig. 2-1-3
1. After ejecting the cassette tape, load the alignment
tape.
2. Within two seconds after the playback screen is
displayed. press the remote control tracking buttons (
4
)
once, and cheak that the ATR display goes off.
3. Press the remote control tracking buttons (
$
) once and
set the tracking to the center.
Note: 
Do not press the tracking buttons (
4
) and (
$
)
continuosly.
4. At first, turn the VR351 fully counterclockwise to make
system microcomputer adjusting mode.
5. Adjust VR351 (SW-P) so that the width of “ T ” be-
comes 6.5 H 
±
 0.5 H as shown in Fig. 2-1-3.
6-6
Color Bar Signal Generator
PAL Color bar signal with 100% white level (EBU color bar signal)
Oscilloscope
Vertical sensitivity
: 5 mV/DIV, external trigger
Bandwidth
: more than 10 MHz
Oscilloscope Probe
Input capacity
: less than 25 pF (10:1)
  less than 40 pF (1:1)
Covering frequency
: DC ~ 40 MHz (10:1)
  DC ~30 MHz (1:1)
Digital Voltmeter
DC range
Alignment Tape
MH-2 (H-7099-052-H)
: SP mode, color bar. 1 kHz
(Color bar signal waveform is described below. Refer to Fig. 2-2-1)
Relay Jig
J-6090-036-A
: 7-wire flat cable for VP-1 PWB assembly (SLV-L44AR)
J-6090-019-A
: 12-wire flat cable for VP-1 PWB assembly (SLV-L66HFAR)
RELAY JIG
Connect the flat cable end from the cylinder assembly to
the VP-1 PWB assembly using the relay jig to provide
simple repairing of the VP-1 PWB assembly, as shown in
Fig. 2-2-3. Further, when adjusting the VP-1 PWB assem-
bly, be sure to make contact an end of shield case with
bracket of the VP-1 PWB assembly to maintain the shield
effect. If the VP-1 PWB assembly does not contact, there
is insufficient ground and no proper play back image can
be obtained.
Color bar signal waveform (MH-2)
Color bar pattern (MH-2) on monitor TV
Cy
an
Green
Ma
g
enta
Red
Blue
1Vp-p
0.7Vp-p
0.3Vp-p
V    U
V  U
Black
0.3Vp-p
100% White
100% 
White
Burst signal
H. Sync signal
75%
White
Y
ello
w
Cy
an
Green
Ma
g
enta
Red
Blue
(75%)
White
Y
ello
w
Fig. 2-2-1
Fig. 2-2-2
Fig. 2-2-3
Relay Jig
J-6090-019-A
VP-1 PWB Assembly
Flat Cable
Bracket
Cylinder
Assembly
Relay Jig
J-6090-036-A
Fig. 2-2-3
(SLV-L44AR)
(SLV-L66HFAR)
VP-1 PWB Assembly
Flat Cable
Cylinder
Assembly
2-2. VIDEO CIRCUIT RELAY JIG
2-2-1 .TEST EQUIPMENT AND STANDARDS REQUIRED
ALIGNMENT TAPE COLOR BAR SIGNAL
6-7
2-3. MTS DECODER CIRCUIT ADJUSTMEN
• If adjusting the MTS Decoder Circuit, special equipment
shown in section 2-3-1. is necessary.
• Improper adjustment will cause loss of performance of
stereo sound and bilingual sound detection.
• Prior to making these adjustments, the other adjustments
except the MTS Decoder should be completed.
2-3-1 . TEST EQUIPMENT AND STANDARDS REQUIRED
TV Multichannel Sound Generator
LMS-238 (Prodused by Leader Electonics Corp.)
Oscilloscope
Standard Audio Signal Generator (SG)
Frequency Counter
Input frequency
: 20 Hz ~ 10MHz
AC Voltmeter
DC Voltmeter
DC Power Supply Unit
Voltage
: 0 ~ 15 V (DC)
Band Path Filter
200 Hz ~ 15 kHz
CP-1 PWB (Foil side)
VR351
VR631
TP633
VR634
VR632
VR635
VR633
TP631
TP635
TP101
Fig. 2-2-4
2-3-2 . LOCATION OF ADJUSTMENT POINTS
6-8
Measuring Point
Measuring Equipment
Adj. Condition
 CH : 1
TV multichannel
E-E mode
 AUDIO OUTPUT    sound generator
   terminal (L)
Oscilloscpe
 CH : 2
Band path filter
 AUDIO OUTPUT  (200 Hz ~ 15kHz)
   terminal (R)
Adj. Location
Adj. Value
VR632 (SEP. LOW)
Minimum level (less than
VR634 (SEP. HIGHT)
15mVp-p)
Notes:
• Set the INPUT switch on the remote control to TUNER.
• Set the VIF/RF OUTPUT switch on the TV Multichannel
Sound Generator to CH-3 or CH-4. And LEVEL volume
control to push (locked the RF output level).
2-3-3. STEREO/SAP FILTER ADJ.
Measuring Point
Measuring Equipment
Adj. Condition
 TP633
Standard audio
Disconnected
signal generator (SG)
Power cord of
Oscilloscope
VCR
Frequency counter
DC power supply unit
Adj. Location
Adj. Value
 VR633 (ST.DBX FIL)
Minimum level (Less than 10 mVp-p)
1. Temporary disconnect the power cord of the VCR to set
the power OFF.
2. Apply 5V(DC) to TP630 from the DC power supply unit.
3. Connect the standard audio signal generator and
frequency counter to TP631, and input 22.9 kHz 
±
 50
Hz, -10 
±
 1 dBM sine wave.
4. After confirming TP633 output on the oscilloscope,
adjust VR633 (ST. DBX FIL) so that the output is
brought to its minimum level (less than 10 mVp-p).
2-3-4. STEREO VCO ADJ.
Measuring Point
Measuring Equipment
Adj. Condition
 TP635
TV multichannel
E-E mode
   sound generator
DC voltmeter
Adj. Location
Adj. Value
 VR633 (VCO)
1. Input the output signal of the TV multichannel sound
generator into the VCR ANT input terminal.
2. Set the TV multichannel sound generator as follows.
   SAP switch : OFF, INT FREQ switch : 300 Hz,
   STEREO switch : L + R, VIF/RF OUTPUT : CH-3 or CH-4.
3. Receive the signal of TV multichannel sound generator.
and confirm so that the “ L + R ” within the monitor TV
when PILOT switch to ON.
4. Set OFF the pilot switch of the TV multichannel sound
generator, then measure the DC output voltage of
TP635 and write the value down.
5. Set ON the pilot switch and confirm that “ ST ” within
the indicator panel lights. If not, adjust VR635 (VCO)
until “ ST ” lights.
6. Measure the output voltage of TP635, and adjust
VR635 (VCO) so that the output voltage agree with the
value (within 
±
 0.03 V) measured in step 3.
2-3-5. INPUT LEVEL ADJ.
1. Input the output signal of the TV multichannel sound
generator into the VCR ANT input terminal.
2. Set the TV multichannel sound generator as follows.
SAP switch : OFF, EXT (MONO) switch : ON.
3. Input 300 
±
 50 Hz sine wave into the EXT INPUT terminal
of the TV multichannel sound generator from the standard
audio signal generator.
4. Connect the AC voltmeter to the EXT INPUT terminal, and
adjust the output level of the standard audio signal
generator so that the input voltage becomes 343.7 
±
 1
mVrms (terminated at 600
).
5. Adjust the VR631 (INPUT LEVEL) so that the AC voltme-
ter connected to TP631 becomes 100 
±
 5mVrms.
2-3-6. SEPARATION ADJ.
Measuring Point
Measuring Equipment
Adj. Condition
 TP631
TV multichannel
E-E mode
   sound generator
Standard audio
   signal generator
AC voltmeter
Adj. Location
Adj. Value
 VR631 (INPUT LEVEL)
100 
±
 5 mVrms
1. Input the output signal of the TV multichannel sound
generator into the VCR ANT input terminal.
2. Connect the oscilloscope to the AUDIO OUTPUT terminal
(L) and (R) of the VCR via the BPF.
3. Set the TV multichannel sound generator as follows.
     SAP switch : OFF, PILOT switch : ON.
4. Receive the signal of TV multichannel sound generator,
and confirm so that the “ L + R ” within the monitor TV
when PILOT switch to ON.
5. Set the TV multichannel sound generator (STEREO switch :
Rch, INT FREQ switch : 3 kHz), and adjust VR632 (SEP.
LOW) so that the output of the AUDIO OUTPUT terminal
(L) is brought to its minimum level (less than 15 mVp-p)
during Rch modulation.
6. Set the TV multichannel sound generator (STEREO switch :
Rch, INT FREQ switch : 300 Hz), and adjust VR634 (SEP.
HIGH) so that the output of the AUDIO OUTPUT terminal
(R) is brought to its minimum level (less than 15 mVp-p)
during Lch modulation.
Page of 68
Display