DOWNLOAD Sony SLV-ED10ME / SLV-ED10MPS / SLV-ED10PS / SLV-ED10SG / SLV-ED40ME / SLV-ED40PS / SLV-ED40SG / SLV-ED60ME / SLV-ED60PS / SLV-ED60SG / SLV-ED70MN / SLV-EZ10AZ / SLV-EZ40AZ / SLV-EZ60AZ / SLV-EZ70AS / SLV-EZ70NZ Service Manual ↓ Size: 20.33 MB | Pages: 85 in PDF or view online for FREE

Model
SLV-ED10ME SLV-ED10MPS SLV-ED10PS SLV-ED10SG SLV-ED40ME SLV-ED40PS SLV-ED40SG SLV-ED60ME SLV-ED60PS SLV-ED60SG SLV-ED70MN SLV-EZ10AZ SLV-EZ40AZ SLV-EZ60AZ SLV-EZ70AS SLV-EZ70NZ
Pages
85
Size
20.33 MB
Type
PDF
Document
Service Manual
Brand
Device
VCR
File
slv-ed10me-slv-ed10mps-slv-ed10ps-slv-ed10sg-slv-e.pdf
Date

Sony SLV-ED10ME / SLV-ED10MPS / SLV-ED10PS / SLV-ED10SG / SLV-ED40ME / SLV-ED40PS / SLV-ED40SG / SLV-ED60ME / SLV-ED60PS / SLV-ED60SG / SLV-ED70MN / SLV-EZ10AZ / SLV-EZ40AZ / SLV-EZ60AZ / SLV-EZ70AS / SLV-EZ70NZ Service Manual ▷ View online

7-1
SECTION  7
ADJUSTMENTS
SLV-ED10/ED40/ED60/ED70/EZ10/EZ40/EZ60/EZ70
1
2
3
4
Mode
SP
SP
EP
EP
Video signal
Color bar
Monoscope
Color bar
Monoscope
Audio signal
(HiFi/Normal)
400 Hz
Time
Seven minutes
Three minutes
Seven minutes
Three minutes
7-1. MECHANICAL  ADJUSTMENTS
Refer to the SERVICE  MANUAL of VHS MECHANICAL AD-
JUSTMENT VI.
7-2. ELECTRICAL  ADJUSTMENTS
2-1.
PRE-ADJUSTMENT  PREPARATIONS
Necessary items and indications for total adjustment of electric
circuit of this machine will be described in this chapter.
2-1-1.
Instruments to be Used
1) Color TV
2) Oscilloscope 1 or 2 phenomena, band more than 30 MHz, de-
lay mode, as provided.
3) NTSC pattern generator
4) PAL pattern generator
5) Digital voltmeter
6) Audio level meter
7) Audio noise meter
8) Audio generator
9) Attenuator
10) Alignment tape
Part Code:  8-192-605-36 KRV-51P (PAL)
Part Code:  8-192-605-32 KRV-51N2 (NTSC)
2-1-2.
Connection
Unless otherwise specified, connect and adjust the measuring in-
struments as shown in the following diagram.
During the adjustment, see the Parts Arrangement
Diagram for Adjustments on Page 7-6.
Fig. 7-2-2
2-1-4.
Alignment Tapes
[Alignment Tape  (KRV-51N2/KRV-51P)]
2-1-3.
Set-up of Adjustment
In this adjustment, PAL or NTSC pattern generator is connected
with LINE input signal terminal. When checking with tuner, con-
nected AERIAL terminal. Check that the amplitudes of video sig-
nal SYNC signal, of picture portions, and of burst signals are flat
at approximately 0.3, 0.7 and 0.3 V, respectively, and that the level
ratio of the burst signal and “red” signal are 0.30: 0.66. Fig. 7-2-2.
shows video signals (color bars) used in adjusting the video sec-
tion.
PAL
NTSC
Video output
(75 
)
Pattern generator
VCR
VIDEO LINE IN
Monitor TV
VIDEO LINE OUT
Fig.  7-2-1
2-1-5.
Specified I/O Level and Impedance
Input/output terminal
Video inputs
LINE IN
: phono jack
1 Vp-p, 75 
, unbalanced, sync negative
Audio inputs
LINE IN
: phono jacks
47 kW, –7.5 dBs (0 dBs = 0.775 Vrms)
More than 10 kW, –4 dBs
Video outputs
LINE OUT: phono jack
1 Vp-p, 75 
, unbalanced, sync negative
Audio outputs
LINE OUT: phono jacks
–7.5 dBs at load impedance 47 k
Output impedance : less than 10 
7-2
2-1-6.
Adjusting Sequence
Make the electrical adjustment in the following sequence.
2-3.
SERVO  SYSTEM  ADJUSTMENT
2-3-1.
RF Switching Position Adjustment
 (MA-350 BOARD)
Purpose:
Adjust the interval between A ch and B ch of tape playback out-
put.
Improve the interchangeability with other tapes and sets.
When it is out of order, the interval appears on the screen, the
screen is disturbed.
Mode
PB
Signal
Alignment tape SP mode
color bar
Measurement Point
CH1: Pin 2 of CN203
CH2: Pin 3 of CN203
(RF SWP)
Measuring Instrument
Oscilloscope
Specified Value
6.5 ± 0.5 H (416 ± 32 µsec)
PAL
6.5 ± 0.5 H (410 ± 32 µsec)
NTSC
Adjusting Method:
1) Connect MA-350 board JS450 to the GND for about 1 second
to activate the RF switching position adjustment mode.
2) Check appear “A P” on FL display.
3) Using the channel + and – buttons, adjust to 6.5 ± 0.5 H.
4) Press the pause button.
Fig. 7-2-3.
Mode
E-E
Measuring Instrument
Digital voltmeter
–10 V check
Measurement Point
Pin 9 of CN201
Specified Value
–9.5 ±0.8 V
+6 V check
Measurement Point
Pin 7, 8 of CN201
Specified Value
5.9 ± 0.2 V
+13 V check
Measurement Point
Pin 2, 3 of CN201
Specified Value
13.8 ± 1.2 V
+35 V check
Measurement Point
Pin 1 of CN201
Specified Value
35.0 ± 3.0 V
2-2.
POWER SUPPLY ADJUSTMENTS
2-2-1.
Power Supply Check
  HS-921SF/921SF1 BOARD,
  SR-708/718 BOARD
Checking Method:
1) Confirm that each voltage meets its specified value.
2-2-2.
+6 V Adjustment
  HS-921SF/921SF1 BOARD,
  SR-708/718 BOARD
Mode
REC or PB
Measuring Instrument
Digital voltmeter
Measurement Point
Pin 7, 8 of CN201
Adjusting Element
RV201 (HS-921SF/921SF1
BOARD)
VR201 (SR-708/718
BOARD)
Specified Value
5.9 ± 0.2 V
Power supply adjustment
Servo system adjustment
Audio system 
adjustment
Tuner system 
adjustment
Approx. 1 Vp-p
Approx. 5 Vp-p
V
enlargement
CH2
CH1
CH2
CH1
Vertical sync. signal
6.5 
±
 0.5 H
(416 
±
 32 
µ
sec) PAL
(410 
±
 32 
µ
sec) NTSC
7-3
2-4.
AUDIO  SYSTEM  ADJUSTMENTS
• Adjust both Lch and Rch.
[Connection]
Fig. 7-2-4.
2-4-1.
Hi-Fi Audio System Adjustment
(SLV-ED60/ED70/EZ60/EZ70)
• Set switches and knobs to the following positions to make ad-
justment unless otherwise specified.
INPUT SELECT switch ................... LINE
AUDIO MONITOR .......................... STEREO
[Adjustment Sequence]
1. AF Switching Position Adjustment
2. Frequency Response Check
3. Overall Level Characteristic and Distortion Factor
Check
4. Overall S/N Check
1.
AF Switching Position Adjustment
      (MA-350 BOARD)
Purpose:
Adjust the interval between A CH and B CH of tape playback
output.  Improve the interchangeability with other tapes and sets.
When it is out of order, noisy sound is increased and big noise is
heard.
Mode
PB
Signal
Alignment tape SP mode
color bar
Measurement point
CH1: Pin 3 of  CN203
CH2: Pin 1 of CN203
Measuring Instrument
Oscilloscope
Specified Value
Fig. 7-2-5
Adjusting Method:
1) Connect MA-350 board JS450 to the GND for about 1 second
to activate the RF switching position adjustment mode.
2) Press the record button to activate the AF switching position
adjustment mode.
3) Check appear “A H” on FL display.
4) Using the channels + and – buttons, minimize a chipped por-
tion.  At this time, confirm that a noisy sound is not heard.
5) Press the pause button.
Fig. 7-2-5.
2.
Frequency Response Check
Purpose:
Confirm that the frequency characteristic is within the specifica-
tion.
Mode
REC and PB (SP, LP mode)
Signal
400 Hz, –7.5 dBs
20 Hz, –7.5 dBs
20 kHz, –7.5 dBs
Measurement point
Audio output terminal
Measurement equipment
Audio level meter
Specified value
0 ± 2 dB
Note:
Tape path adjustment must have been completed.
Confirmation Method:
1) Supply a signal of 400 Hz, –7.5 dBs to both L and R channels
of Audio Line Input.
2) Connect the audio level meter to the Audio Line Output.
3) Adjust the attenuator so that the audio level meter will indi-
cate –7.5 dBs.
4) Make recording.
5) Set an audio line input signal to 20 Hz and make recording.
6) Set an audio line input signal to 20 kHz and make recording.
7) Playback a recorded portion, and measure output levels at 400
Hz and 20 Hz and 20 kHz.
8) Confirm that the 20 Hz and 20 kHz playback output level within
a range of the 400 Hz playback output level 0 ± 2 dB.
CH2
CH1
RF SWP
OK
NG
Audio
generator
Attenuator
600 
47 k
VCR
Audio level meter or
distortion meter
AUDIO LINE OUT
AUDIO LINE IN
   Feed signal both 
   channelssimultaneously.
7-4
3. Overall Level Characteristic and Distortion Factor
Check
Purpose:
Check the record level, play level, and distortion factor against the
reference input.
Mode
REC and PB (SP mode)
Signal
400 Hz, –7.5 dBs
Measurement point
Audio output terminal
Measurement equipment
Audio level meter and
distortion factor meter
Specified value
Playback level: –7.5 ± 2.0 dBs
Distortion factor: 1% or less
Confirmation Method:
1) Supply an audio signal of 400 Hz, –7.5 dBs simultaneously to
both L and R channels of Audio Line Input.
2) Make recording
3) Play back a recorded portion.
4) Confirm that a playback level is –7.5 ±2.0 dBs.
5) Confirm that a distortion factor is within 1%.
4. Overall S/N Check
Purpose:
Confirm that the S/N is within the specification.
Mode
REC and PB (SP mode)
Signal
Short
Measurement point
Audio output terminal
Measurement equipment
Audio noise meter
Specified value
–67.5 dBs or less
Confirmation Method:
1) Connect both L and R channels of audio line input to the GND.
2) Start recording.
3) Play the recorded part to confirm that the noise is below –67.5
dBs.
2-4-2.
Normal Audio System Adjustment
• Make adjustment in the SP mode, unless otherwise specified.
Use a normal VHS cassette for an adjustment tape.
• Set AUDIO MONITOR  to normal.
[Adjustment Sequence]
1. ACE Head Adjustment
2. E-E Output Level Check
3. Frequency Response Check
4. Overall Level Characteristic and Distortion Factor
Check
5. Overall S/N Check
1. ACE Head Adjustment
Refer to the SERVICE MANUAL of VHS MECHANICAL AD-
JUSTMENT VI.
2. E-E Output Level Check
(SLV-ED10/ED40/EZ10/EZ40)
Purpose:
Confirm that the output level against the reference input is within
the specification.
Mode
E-E
Signal
L, R: 400 Hz, –7.5 dBs
Measurement point
Audio output terminal
Measurement equipment
Audio level meter
Specified value
–7.5 ± 3.0 dBs
Confirmation Method:
1) Simultaneously input a signal of 400 Hz, –7.5 dBs to both L
and R channels of Audio Line Input.
2) Confirm that the audio output level is –7.5 ± 3.0 dBs.
      (This level only can appear with mono models)
3. Frequency Response Check
Purpose:
Confirm that the frequency characteristic is within the specifica-
tion.
Mode
REC and PB (SP mode)
Signal
400 Hz, –17.5 dBs
7 kHz, –17.5 dBs
Measurement point
Audio output terminal
Measurement equipment
Audio level meter
Specified value
2.5 ± 4.0 dB
Tape path adjustment must have been completed.
Confirmation Method:
1) Supply a signal of 400 Hz, –17.5 dBs to both L and R chan-
nels of Audio Line Input.
2) Connect the audio level meter to the Audio Line Output.
3) Adjust the attenuator so that the audio level meter will indi-
cate –17.5 dBs.
4) Make recording in the SP mode.
5) Set an audio line input signal to 7 kHz and make recording.
6) Playback a recorded portion, and measure output levels at 400
Hz and 7 kHz.
7) Confirm that the 7 kHz playback output level within a range
of the 400 Hz playback output level 2.5 ± 4.0 dB.
Page of 85
Display

Click on the first or last page to see other SLV-ED10ME / SLV-ED10MPS / SLV-ED10PS / SLV-ED10SG / SLV-ED40ME / SLV-ED40PS / SLV-ED40SG / SLV-ED60ME / SLV-ED60PS / SLV-ED60SG / SLV-ED70MN / SLV-EZ10AZ / SLV-EZ40AZ / SLV-EZ60AZ / SLV-EZ70AS / SLV-EZ70NZ service manuals if exist.