Sony SLV-ED100ME / SLV-ED100MI / SLV-ED100ML / SLV-EZ2000S / SLV-EZ2000Y / SLV-K990PS / SLV-KH9ME / SLV-KH9PS Service Manual ▷ View online

7-2
2-3.
SERVO  SYSTEM  ADJUSTMENT
2-3-1.
RF Switching Position Adjustment
(MA-361 BOARD)
Purpose:
Adjust the interval between A ch and B ch of tape playback out-
put.
Improve the interchangeability with other tapes and sets.
When it is out of order, the interval appears on the screen, the
screen is disturbed.
Mode
PB
Signal
Alignment tape SP mode
color bar
Measurement Point
CH1: Pin 2 of CN202
CH2: Pin 3 of CN202
(RF SWP)
Measuring Instrument
Oscilloscope
Specified Value
6.5 
±
 0.5 H (416 
±
 32 
µ
sec)
PAL
6.5 
±
 0.5 H (410 
±
 32 
µ
sec)
NTSC
Adjusting Method:
1) Connect MA-361 board JS004 to the GND for about 1 second
to activate the RF switching position adjustment mode.
2) Check appear “A P” on LCD display.
3) Using the PROGRAM + and – buttons, adjust to 6.5 
±
 0.5 H.
4) Press the pause button.
Fig. 7-2-3.
Mode
E-E
Measuring Instrument
Digital voltmeter
–11 V check
Measurement Point
Pin 9 of CN201
Specified Value
–11.5 
±
 0.5 V (EXCEPT KH9)
–11.5 
±
 0.8 V (KH9)
+6 V check
Measurement Point
Pin 7, 8 of CN201
Specified Value
5.95 
±
 0.15 V
+13 V check
Measurement Point
Pin 2, 3 of CN201
Specified Value
13.3 
±
 0.5 V
+35 V check
Measurement Point
Pin 1 of CN201
Specified Value
39.0 
±
 2.0 V (EXCEPT KH9)
39.5 
±
 2.5 V (KH9)
2-2.
POWER SUPPLY ADJUSTMENTS
2-2-1.
Power Supply Check
(HS-028SF)
Checking Method:
1) Confirm that each voltage meets its specified value.
2-2-2.
+6 V Adjustment
(HS-028SF)
Mode
REC or PB
Measuring Instrument
Digital voltmeter
Measurement Point
Pin 7, 8 of CN201
Adjusting Element
RV201 (HS-028SF BOARD)
Specified Value
5.9 
±
 0.15 V
Power supply adjustment
Servo system adjustment
Audio system 
adjustment
Tuner system 
adjustment
Approx. 1 Vp-p
Approx. 5 Vp-p
V
enlargement
CH2
CH1
CH2
CH1
Vertical sync. signal
6.5 
±
 0.5 H
(416 
±
 32 
µ
sec) PAL
(410 
±
 32 
µ
sec) NTSC
2-1-5.
Specified I/O Level and Impedance
Input/output terminal
Video inputs
LINE IN
: phono jack
1 Vp-p, 75 
, unbalanced, sync negative
Audio inputs
LINE IN
: phono jacks
47 kW, –7.5 dBs (0 dBs = 0.775 Vrms)
More than 10 kW, –4 dBs
Video outputs
LINE OUT : phono jack
1 Vp-p, 75 
, unbalanced, sync negative
Audio outputs
LINE OUT : phono jacks
–7.5 dBs at load impedance 47 k
Output impedance : less than 10 
2-1-6.
Adjusting Sequence
Make the electrical adjustment in the following sequence.
7-3
2-4.
AUDIO  SYSTEM  ADJUSTMENTS
• Adjust both Lch and Rch.
[Connection]
Fig. 7-2-4.
2-4-1.
Hi-Fi Audio System Adjustment
• Set switches and knobs to the following positions to make ad-
justment unless otherwise specified.
INPUT SELECT switch ................... LINE
AUDIO MONITOR .......................... STEREO
[Adjustment Sequence]
1. AF Switching Position Adjustment
2. Frequency Response Check
3. Overall Level Characteristic and Distortion Factor
Check
4. Overall S/N Check
1.
AF Switching Position Adjustment
      (MA-361 BOARD)
Purpose:
Adjust the interval between A CH and B CH of tape playback
output.  Improve the interchangeability with other tapes and sets.
When it is out of order, noisy sound is increased and big noise is
heard.
Mode
PB
Signal
Alignment tape SP mode
color bar
Measurement point
CH1: Pin 3 of  CN202
CH2: Pin 1 of CN202
Measuring Instrument
Oscilloscope
Specified Value
Fig. 7-3-5
Adjusting Method:
1) Connect MA-361 board JS004 to the GND for about 1 second
to activate the RF switching position adjustment mode.
2) Press the record button to activate the AF switching position
adjustment mode.
3) Check appear “A H” on LCD display.
4) Using the PROGRAM + and – buttons, minimize a chipped
portion.  At this time, confirm that a noisy sound is not heard.
5) Press the pause button.
Fig. 7-2-5.
2.
Frequency Response Check
Purpose:
Confirm that the frequency characteristic is within the specifica-
tion.
Mode
REC and PB (SP, LP mode)
Signal
400 Hz, –17.5 dBs
20 Hz, –17.5 dBs
20 kHz, –17.5 dBs
Measurement point
Audio output terminal
Measurement equipment
Audio level meter
Specified value
±
 2 dB
Note:
Tape path adjustment must have been completed.
Confirmation Method:
1) Supply a signal of 400 Hz, –17.5 dBs to both L and R chan-
nels of Audio Line Input.
2) Connect the audio level meter to the Audio Line Output.
3) Adjust the attenuator so that the audio level meter will indi-
cate –17.5 dBs.
4) Make recording.
5) Set an audio line input signal to 20 Hz and make recording.
6) Set an audio line input signal to 20 kHz and make recording.
7) Playback a recorded portion, and measure output levels at 400
Hz and 20 Hz and 20 kHz.
8) Confirm that the 20 Hz and 20 kHz playback output level within
a range of the 400 Hz playback output level 0 
±
 2 dB.
CH2
CH1
RF SWP
OK
NG
Audio
generator
Attenuator
600 
47 k
VCR
Audio level meter or
distortion meter
AUDIO LINE OUT
AUDIO LINE IN
   Feed signal both 
   channelssimultaneously.
7-4
3. Overall Level Characteristic and Distortion Factor
Check
Purpose:
Check the record level, play level, and distortion factor against the
reference input.
Mode
REC and PB (SP mode)
Signal
400 Hz, –7.5 dBs
Measurement point
Audio output terminal
Measurement equipment
Audio level meter and
distortion factor meter
Specified value
Playback level: –7.5 
±
 2.0 dBs
Distortion factor: 1% or less
Confirmation Method:
1) Supply an audio signal of 400 Hz, –7.5 dBs simultaneously to
both L and R channels of Audio Line Input.
2) Make recording
3) Play back a recorded portion.
4) Confirm that a playback level is –7.5 
±
2.0 dBs.
5) Confirm that a distortion factor is within 1%.
4. Overall S/N Check
Purpose:
Confirm that the S/N is within the specification.
Mode
REC and PB (SP mode)
Signal
Short
Measurement point
Audio output terminal
Measurement equipment
Audio noise meter
Specified value
–67.5 dBs or less
Confirmation Method:
1) Connect both L and R channels of audio line input to the GND.
2) Start recording.
3) Play the recorded part to confirm that the noise is below –67.5
dBs.
2-4-2.
Normal Audio System Adjustment
• Make adjustment in the SP mode, unless otherwise specified.
Use a normal VHS cassette for an adjustment tape.
• Set AUDIO MONITOR  to normal.
[Adjustment Sequence]
1. ACE Head Adjustment
2. E-E Output Level Check
3. Frequency Response Check
4. Overall Level Characteristic and Distortion Factor
Check
5. Overall S/N Check
1. ACE Head Adjustment
Refer to the SERVICE MANUAL of VHS MECHANICAL AD-
JUSTMENT VI.
2. E-E Output Level Check
Purpose:
Confirm that the output level against the reference input is within
the specification.
Mode
E-E
Signal
L, R: 400 Hz, –7.5 dBs
Measurement point
Audio output terminal
Measurement equipment
Audio level meter
Specified value
–7.5 
±
 3.0 dBs
Confirmation Method:
1) Simultaneously input a signal of 400 Hz, –7.5 dBs to both L
and R channels of Audio Line Input.
2) Confirm that the audio output level is –7.5 
±
 3.0 dBs.
      (This level only can appear with mono models)
3. Frequency Response Check
Purpose:
Confirm that the frequency characteristic is within the specifica-
tion.
Mode
REC and PB (SP mode)
Signal
400 Hz, –17.5 dBs
7 kHz, –17.5 dBs
Measurement point
Audio output terminal
Measurement equipment
Audio level meter
Specified value
2.5 
±
 4.0 dB
Tape path adjustment must have been completed.
Confirmation Method:
1) Supply a signal of 400 Hz, –17.5 dBs to both L and R chan-
nels of Audio Line Input.
2) Connect the audio level meter to the Audio Line Output.
3) Adjust the attenuator so that the audio level meter will indi-
cate –17.5 dBs.
4) Make recording in the SP mode.
5) Set an audio line input signal to 7 kHz and make recording.
6) Playback a recorded portion, and measure output levels at 400
Hz and 7 kHz.
7) Confirm that the 7 kHz playback output level within a range
of the 400 Hz playback output level 2.5 
±
 4.0 dB.
7-5
7-6 E
4. Overall Level Characteristic and Distortion Factor
Check
Purpose:
Check the record level, play level, and distortion factor against the
reference input.
Mode
REC and PB (SP mode)
Signal
400 Hz, –7.5 dBs
Measurement point
Audio output terminal
Measurement equipment
Audio level meter and
distortion factor meter
Specified value
Playback level: –7.5 
±
 4.0 dBs
Distortion factor: 4% or less
Confirmation Method:
1) Supply an audio signal of 400 Hz, –7.5 dBs simultaneously to
both L and R channels of Audio Line Input.
2) Make recording
3) Play back a recorded portion.
4) Confirm that a playback level is –7.5 
±
 4.0 dBs.
5) Confirm that a distortion factor is within 4%.
5. Overall S/N Check
Purpose:
Confirm that the S/N is within the specification.
Mode
REC and PB (SP mode)
Signal
Short
Measurement point
Audio output terminal
Measurement equipment
Audio noise meter
Specified value
–46.0 dBs or less
Confirmation Method:
1) Connect both L and R channels of audio line input to the GND.
2) Start recording.
3) Play the recorded part to confirm that the noise is below –46.0
dBs.
2-5.
VIDEO  SYSTEM  ADJUSTMENT
2-5-1.
VCO Oscillation Frequency Adjustment
(MA-361 Board)
Purpose:
Adjust to set the character position on the screen.
Mode
E-E
Signal
Color bar
Measurement point
Pin @§ of IC401
Measurement equipment
Oscilloscope (DC mode)
Adjusting Element
CT401
Specified value
2.75 
±
 0.05 V
2-7.
PARTS  ARRANGEMENT  DIAGRAM  FOR  ADJUSTMENTS
MA-361 BOARD (Side A)
HS-028SF BOARD (Side A)
GK-12 BOARD (Side A)
2-6.
TUNER  SYSTEM  ADJUSTMENT
[Connection]
Fig. 7-2-7
2-6-1.
Separation Adjustment (SLV-EZ2000S/K990)
Purpose:
Mixed audio signal separate Lch and Rch.
Mode
E-E
Signal
VIDEO:
  color bar
  (White 100% modulation)
AUDIO:
  L
400 Hz 60% modulation
  R 1 kHz 60% modulation
ELECTRIC FIELD:
  60–80 dBs/75 
 Term
Measurement point
Audio output terminal
Measurement equipment
Audio level meter
Adjusting Element
RV001
Specified value
minimum
47 k
VCR
Audio level
meter
Up channel
convertor
RF IN
AUDIO LINE OUT
L
R
RV201
CN201
6V ADJ
1
9
RV001
IC001
1
11
33
34
44
22
12
23
SEPARATION ADJ
V
DD
 = 5.0V
1H
2.75
±
0.05V
GND = 0V
Fig. 7-2-6.
JS004
CN202
IC401
CT401
30
16
1
15
1
4
Page of 115