DOWNLOAD Sony GV-A500 Service Manual ↓ Size: 3.33 MB | Pages: 103 in PDF or view online for FREE

Model
GV-A500
Pages
103
Size
3.33 MB
Type
PDF
Document
Service Manual
Brand
Device
VCR / S/M GV-A500/A500E''97 US CAN E
File
gv-a500.pdf
Date

Sony GV-A500 Service Manual ▷ View online

5-2
1-1-2.
Adjusting Remote Commander
The adjusting remote commander is used for changing the
calculation coefficient in signal processing, EVR data, etc. The
adjusting remote commander performs bidirectional communication
with the unit using the remote commander signal line (LANC). The
resultant data of this bidirectional communication is written in the
non-volatile memory.
1. Using the adjusting remote commander
1)
Connect the adjusting remote commander to the LANC
terminal.
2)
Adjust the HOLD switch of the adjusting remote commander
to “HOLD” (SERVICE position).
If it has been properly connected, the LCD on the adjusting
remote commander will display as shown in Fig. 5-1-7.
Fig. 5-1-2.
3)
Operate the adjusting remote commander as follows.
• Changing the page
The page increases when the EDIT SEARCH+ button is
pressed, and decreases when the EDIT SEARCH– button is
pressed. There are altogether 16 pages, from 0 to F.
Page
Data
Address
Hexadecimal
notation
LCD Display
Decimal notation
conversion value
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 8 9 A b c d E F
0 1 2 3 4 5 6 7 8 9 10 11 12 1314 15
• Changing the address
The address increases when the FF (
)) button is pressed,
and decreases when the REW (
0) button is pressed. There
are altogether 256 addresses, from 00 to FF.
• Changing the data (Data setting)
The data increases when the PLAY (
() button is pressed,
and decreases when the STOP (
p) button is pressed.
There are altogether 256 data, from 00 to FF.
• Writing the adjustment data
The PAUSE button must be pressed to write the adjustment
data (D, E, F page) in the nonvolatile memory.
(The new adjustment data will not be recorded in the
nonvolatile memory if this step is not performed.)
4)
Select page: 0, address: 01, and set the data to 01, and enables
Page D and E, F to be adjusted.
5)
After completing all adjustments, set page: 0, address: 01, data:
00 and turn off the main power supply (7.2V) once.
2. Precautions upon using the adjusting remote
commander
Mishandling of the adjusting remote commander may erase the
correct adjustment data at times. To prevent this, it is recommended
that all adjustment data be noted down before beginning adjustments
and new adjustment data after each adjustment.
5-3
1-1-3.
Page D Address
Note 1 :
The initial adjustment data value is the value after “Page D, Page E, Page F Data Initialization” and “Page D Data Modification”
have been executed. It is different from the value after all adjustments have been executed.
Note 2 :
The 
 mark shown in the adjustment data memo column indicates that the address data is fixed and same as the initial value.
Address
00 to 0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
GV-A500
00
02
7E
30
D6
F0
80
0E
00
12
40
00
00
34
00
00
2D
10
1E
19
12
64
02
F9
88
8D
A8
BD
C8
05
03
01
01
7C
36
4B
07
88
C9
02
0A
04
0A
32
04
04
04
03
AEP,UK
00
07
FE
30
56
F0
80
0E
00
12
40
00
00
34
00
00
2D
10
1E
19
12
50
02
F9
88
8D
A8
BD
C8
05
03
01
01
7C
36
4B
07
88
C9
02
0A
04
0A
32
04
04
04
03
E,HK
00
07
FE
30
D6
F0
80
0E
00
12
40
00
00
34
00
00
2D
10
1E
19
12
50
02
F9
88
8D
A8
BD
C8
05
03
01
01
7C
36
4B
07
88
C9
02
0A
04
0A
32
04
04
04
03
Memo
Column







































GV-A500E
Initial Value
Adjustment Data
Address
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64 to FF
GV-A500
76
6D
5D
65
5B
94
7C
41
67
40
80
76
00
80
00
00
A1
DA
AEP,UK
84
9B
67
7D
76
9B
80
90
7E
7C
80
84
67
80
F0
60
A1
DA
E,HK
84
9B
67
7D
76
9B
80
90
7E
7C
80
84
67
80
F0
60
A1
DA
Memo
Column













GV-A500E
Initial Value
Adjustment Data
Table 5-1-1 .
5-4
1-1-4.
Page F Address
Note 1 :
The initial adjustment data value is the value after “Page D, Page E, Page F Data Initialization” and “Page F Data Modification”
have been executed. It is different from the value after all adjustments have been executed.
Note 2 :
The 
 mark shown in the adjustment data memo column indicates that the address data is fixed and same as the initial value.
Address
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
GV-A500
B4
B8
5E
45
54
69
8A
00
00
00
00
00
00
00
00
00
00
00
00
50
00
23
52
00
02
3B
00
7C
80
1F
00
46
00
FF
3B
7D
56
00
00
AEP,UK
BA
B8
5E
47
58
6B
8E
00
00
00
00
00
00
00
00
00
00
00
00
51
10
23
52
02
02
3B
00
7C
80
1F
00
46
00
FF
3B
7D
56
00
00
E,HK
BA
B8
5E
47
58
6B
8E
00
00
00
00
00
00
00
00
00
00
00
00
51
10
23
52
02
02
3B
00
7C
80
1F
00
46
00
FF
3B
7D
56
00
00
Memo
Column
















GV-A500E
Initial Value
Adjustment Data
Address
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
GV-A500
A6
1A
15
24
8C
11
00
0A
00
0A
3C
A0
80
80
30
49
1B
1B
AE
42
44
34
2A
89
59
38
41
25
00
19
00
16
52
52
7A
8D
7A
55
A8
00
9A
50
7B
B3
99
70
A8
70
AEP,UK
A6
1A
15
24
8C
11
00
0A
00
0A
3C
A0
80
80
30
49
1B
1B
AE
42
44
34
2A
89
59
38
41
25
00
19
00
16
52
52
7A
8D
7A
55
A8
00
9A
50
7B
B3
AA
70
A2
70
E,HK
A6
1A
15
24
8C
11
00
0A
00
0A
3C
A0
80
80
30
49
1B
1B
AE
42
44
34
2A
89
59
38
41
25
00
19
00
16
52
52
7A
8D
7A
55
A8
00
9A
50
7B
B3
AA
70
A2
70
Memo
Column



GV-A500E
Initial Value
Adjustment Data
Table 5-1-2 (1).
5-5
Address
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
GV-A500
D5
D5
EA
EA
8B
80
89
80
B8
B8
B1
B1
80
80
80
80
7D
7D
80
80
00
80
80
00
7C
AA
A0
C3
0C
18
77
40
75
73
12
8A
A5
68
4A
F0
00
01
6C
40
68
A0
70
40
68
70
40
25
58
AEP,UK
D5
D5
EA
EA
93
8C
93
8C
B8
B8
B1
B1
80
80
80
80
80
80
80
00
00
00
00
00
92
00
00
00
0C
00
77
40
75
73
12
8A
A5
68
4A
F0
00
01
6C
40
28
60
40
29
28
70
40
25
58
E,HK
D5
D5
EA
EA
93
8C
93
8C
B8
B8
B1
B1
80
80
80
80
80
80
80
00
00
00
00
00
92
00
00
00
0C
00
77
40
75
73
12
8A
A5
68
4A
F0
00
01
6C
40
28
60
40
29
28
70
40
25
58
Memo
Column

































GV-A500E
Initial Value
Adjustment Data
Address
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
GV-A500
F0
40
3D
58
FF
40
30
78
70
4C
06
28
FF
30
10
62
91
62
B2
62
91
62
A2
04
E5
04
F7
40
00
B3
B3
21
05
11
06
71
35
20
00
22
80
30
40
20
50
1B
4B
00
00
00
DF
FD
DD
AEP,UK
60
40
10
28
80
40
10
28
70
30
00
28
E0
30
00
60
91
70
92
70
A2
70
A3
04
D5
04
D6
40
00
B3
B3
10
01
10
03
40
32
00
00
22
80
20
40
30
50
2B
4B
00
00
00
BF
CE
DF
E,HK
60
40
10
28
80
40
10
28
70
30
00
28
E0
30
00
60
91
70
92
70
A2
70
A3
04
D5
04
D6
40
00
B3
B3
10
01
10
03
40
32
00
00
22
80
20
40
30
50
2B
4B
00
00
00
BF
CE
DF
Memo
Column




















































GV-A500E
Initial Value
Adjustment Data
Table 5-1-2 (2).
Page of 103
Display

Click on the first or last page to see other GV-A500 service manuals if exist.