Sony KV-XF25M80 (serv.man2) Service Manual ▷ View online

 25 
KV
-XF25M80
RM-954
REMOVAL OF ANODE-CAP
NOTE : After removing the anode, short circuit the anode of the picture tube and
the anode cap to the metal chassis, CRT shield or carbon paint on the
CRT.
REMOVING PROCEDURES
1
Do not damage the surface of anode-caps with sharp shaped objects.
2
Do not press the rubber too hard so as not to damage the inside of anode-cap.
A metal fitting called the shatter-hook terminal is built into the rubber.
3
Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage the rubber.
HOW TO HANDLE AN ANODE-CAP
3
When one side of the rubber cap is separated from the anode button,  the anode-cap
can be removed by turning up the rubber cap and pulling it up in the direction of the
arrow 
c
.
2
Using a thumb pull up the rubber cap firmly in the direction indicated by the arrow 
b
.
1
Turn up one side of the rubber cap in the direction indicated by the arrow 
a
.
a
a
b
b
c
Anode button
– 26 –
KV-XF25M80
RM-954
The following adjustments should be made when a complete
realignment is required or a new picture tube is installed.
These adjustments should be performed with rated power
supply voltage unless otherwise noted.
Controls and switches should be set as follows unless otherwise noted:
PICTURE control ...........................................................  normal
BRIGHTNESS control ...................................................  normal
Perform the adjustments in the following order :
1. Beam Landing
2. Convergence
3. Focus
4. White Balance
Note :  Test Equipment Required.
1. Color-bar/Pattern Generator
2. Degausser
3. Oscilloscope
SECTION 3
SET-UP ADJUSTMENTS
................................................................................................................................................................................................................................
Fig. 3-2
Neck assy
G2
G1
G3
Behind the G2 edge
Fig. 3-1
Fig. 3-5
Purity control
corrects this area.
Disk magnets or rotatable
disk magnets correct these
areas (a-d).
Deflection yoke positioning
corrects these areas.
a
b
b
c
c
d
d
a
Fig. 3-4
Red
Blue
Green
}
normal
Preparation :
In order to reduce the influence of geomagnetism on the set's
picture tube, face it east or west.
Switch on the set's power and degauss with the degausser.
3-1. BEAM LANDING
1. Input a white signal with the pattern generator.
Contrast
Brightness
2. Position neck assy as shown in Fig3-2.
3. Set the pattern generator raster signal to a green raster.
4. Move the deflection yoke to the rear and adjust with the  purity
control so that the green is at the center and the blue and the red
take up equally sized areas on each side.
(See Figures 3-1 through 3-4.)
5. Move the deflection yoke forward and adjust so that the entire
screen is green. (See Figure 3-2.)
6. Switch the raster signal to blue, then to red and verify the
condition.
7. When the position of the deflection yoke has been decided,
fasten the deflection yoke with the screws and DY spacers.
8. If the beam does not land correctly in all the corners, use a
magnet to adjust it.
(See Figure 3-5.)
Purity control
Fig. 3-3
– 27 –
KV-XF25M80
RM-954
3-2. CONVERGENCE
Preparation :
Before starting this adjustment, adjust the focus, horizontal size
and vertical size.
Minimize the brightness setting.
Provide dot pattern.
(1)
Horizontal and Vertical Static Convergence
1. (Moving horizontally), adjust the H.STAT control so that the
red, green and blue dots are on top of each other at the center of
the screen.
2. (Moving vertically), adjust the V.STAT magnet so that the red,
green and blue dots are on top of each other at the center of the
screen.
3. If the H.STAT variable resistor cannot bring the red, green and
blue dots together at the center of the screen, adjust the
horizontal convergence with the H.STAT variable resistor and
the V.STAT magnet in the manner given below.
(In this case, the H.STAT variable resistor and the V.STAT
magnet influence each other, so be sure to perform adjustments
while tracking.)
R     G     B
G
R
B
Center dot
C board
RV 702
V.STAT Magnet
H. STAT VR
1
V. STAT
2
H. STAT VR
BMC (Hexapole)
V.STAT
DY pocket
Purity
V.STAT
BMC
Purity
3
R
R
R
R
G
G
G
G
B
B
B
B
a
a
a
b
b
b
b
R
R
G
G
B
B
a
a
b
b
b
– 28 –
KV-XF25M80
RM-954
5
Y separation axis correction magnet adjustment.
1. Receive the cross-hatch signal and adjust [PICTURE] to [MIN]
and [BRIGHTNESS] to [STANDARD].
2. Adjust the Y separation axis correction magnet on the neck
assembly so that the horizontal lines at the top and bottom of
the screen are straight.
Blue
Red
VM1 board
Blue
Red
VM1 board
Neck assy
Neck assy
Note
1. The Red and Blue magnets should be equally far from the
horizontal center line.
2. Do not separate the Red and Blue magnets too far. (Less than
8 mm)
(2) Dynamic Convergence Adjustment
Preparation:
Before starting this adjustment, adjust the horizontal static
convergence and the vertical static convergence
R B
R B
TLH
TLV
YCH
XCV
B
R
R
B
4
BMC (Hexapole) Magnet.
If the red, green and blue dots are not balanced or aligned, then
use the BMC magnet to adjust in the manner described below.
R G
B
R
G
B
R
G B
R
B
R
G
G
G
B
R
B