– 5 –
KV-SZ29M31/M60K
RM-GA002
SECTION 1
DISASSEMBLY
1-2.
SPEAKER REMOVAL
1-3.
CHASSIS ASSY REMOVAL
1-4.
SERVICE POSITION
1-5.
H1 BOARD REMOVAL
1-1.
REAR COVER REMOVAL
1-6.
A BOARD REMOVAL
1 Twelve screws
     (+BVTP 4 × 16
       Type2 IT-3)
2 Rear cover
1 Two screws
          Tapping screw 
       (+PWH 4x16)
2 H1 Board    
1 Two Hooks     
1 A Board
– 6 –
KV-SZ29M31/M60K
RM-GA002
1-8.
PICTURE TUBE  REMOVAL
Note:
• The picture tube is upside down for KV-SZ29M31 (South Africa) only, and the position for the anode cap and tension springs
are changed accordingly.
• Please make sure the TV set is not in standing position before removing necessary CRT support located on bottom right
and left.
1) Remove the rear cover.
2) Unplug all interconnecting leads from the Deflection yoke, Neck assy, Degaussing Coil and CRT grounding strap. Remove
Chassis Assy.
3) Place the TV set with the CRT face down on a cushion jig.
qd
 Loosen the Deflection Yoke
fixing screw and remove
qa
 Earth Coating Assy
4
 Anode Cap Removal
7 Band, DGC Removal (x1)
5 CV Board Removal
6 Loosen the Neck Assembly
fixing screw and remove VM coil
9
 Holder, DGC Removal (x2)
8
 Spring Tension Removal (x2)
qf
 Screw Tapping
     7+ Crown Washer
0
 Degaussing Coil
qs
 Supports, CRT(2) Removal
1-7.
K BOARD REMOVAL (KV-SZ29M60K)
1
 Two Holders
2
 K board
– 7 –
KV-SZ29M31/M60K
RM-GA002
• REMOVAL OF ANODE-CAP
Note:
• After removing the anode, short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or
carbon paint on the CRT.
REMOVING PROCEDURES
Turn up one side of the rubber cap in the direction
indicated by the arrow a.
Using a thumb pull up the rubber cap firmly in the direction
indicated by the arrow b.
When one side of the rubber cap is separated from the
anode button,  the anode-cap can be removed by turning
up the rubber cap and pulling it up in the direction of the
arrow 
c.
HOW TO HANDLE AN ANODE-CAP
Do not damage the surface of anode-caps with sharp
shaped objects.
Do not press the rubber too hard so as not to damage
the inside of anode-cap.
A metal fitting called the shatter-hook terminal is built
into the rubber.
Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage the
rubber.
a
a
b
b
c
 Anode Button
– 8 –
KV-SZ29M31/M60K
RM-GA002
The following adjustments should be made when a complete
realignment is required or a new picture tube is installed.
The controls and switch should be set as follows unless
otherwise noted:
Picture Control....................................."NORMAL"
Brightness Control..............................."NORMAL"
Perform the adjustments in order as follows :
1. Beam Landing
2. Convergence
3. Focus
4. G2(SCREEN)
5. White Balance
Note : Test Equipment Required.
1. Pattern Generator
5. Oscilloscope
2. Degausser
6. Landing Checker
3. DC Power Supply
7. XCV Adjuster
4. Digital Multimeter
SECTION 2
SET-UP ADJUSTMENTS
Preparation :
• Feed in the white pattern signal.
• Before starting, degauss the entire screen with the
degausser.
• In order to reduce the geomagnetism on the set's picture
tube, face it east or west.
2-1. BEAM LANDING ADJUSTMENT
1. Input a raster signal with the pattern generator.
2. Loose the deflection yoke(DY) mounting screw, and set
the purity control to the center as shown below:-
3. Position VM coil as shown below:-
4. Set the raster signal of the pattern generator to green.
5. Move the DY backward and adjust the purity control so
that green is in the center and blue and red are at the
sides evenly.
Red
Blue
Green
a
b
b
c
c
d
d
a
Purity control
corrects this area.
Disc magnets or rotatable
disc magnets correct these
areas (a-d).
Deflection yoke positioning
corrects these areas.
Purity control
VM coil
G2
G1
G3
Align the edge of
the VM coil with
the edge of the G3 grid.
G4
......................................................................................................................................................................................................................
6. Then move the DY forward and adjust so that the entire
screen becomes green.
7. Now switch over raster signal to red then blue and
confirm the condition.
8. When the position of the DY is determined, tighten it with
the DY mounting screw.
9. If the beam does not land correctly in all the corners of
the screen, use magnet disc to correct it.
Page of 80