– 9 –
KV-SW34M50
RM-W104
The following adjustments should be made when a
complete realignment is required or a new picture tube is
installed.
Set the controls as follows unless otherwise noted:
VIDEO MODE: .................................................... Standard
PICTURE CONTROL: ......................................... Normal
BRIGHTNESS CONTROL: ................................. Normal
Perform the adjustments in the following order :
1. Beam Landing
2. Convergence
3. Focus
4. Screen(G2)
5. White Balance
Note : Test Equipment Required.
1. Pattern Generator
2. Degausser
3. DC Power Supply
4. Digital Multimeter
5. Oscilloscope
SECTION 2
SET-UP ADJUSTMENTS
Preparation :
In order to reduce the influence of geomagnetism on
the set's picture tube, face it east or west.
Switch on the set's power and degauss with the
degausser.
2-1. BEAM LANDING
PICTURE MODE: DYNAMIC
1. Input a white signal with the pattern generator.
Contrast
Brightness
2. Position neck assy as shown in Fig 2-1.
3. Set the pattern generator raster signal to a green
raster.
4. Move the deflection yoke to the rear and adjust with
purity control so that the green is at the center and the
blue and the red take up equally sized areas on each
side. (Figures 2-2 through 2-4.)
5. Move the deflection yoke forward and adjust so that the
entire screen is green. (Figure 2-2.)
6. Switch the raster signal to blue, then to red and verify
the condition.
7. When the position of the deflection yoke have been
decided, fasten the deflection yoke with the screws and
DY spacers.
8. If the beam does not land correctly in all the corners,
use a magnet to adjust it.
(Figure 2-5.)
Fig. 2-1
Fig. 2-2
Fig. 2-4
Fig. 2-3
Red
Blue
Green
a
b
b
c
c
d
d
a
Purity control
corrects this area.
Disk magnets or rotatable
disk magnets correct these
areas (a-d).
Deflection yoke positioning
corrects these areas.
Purity control
Neck assy
G2
G1
G3
Align the edge of
the neck assy with
the edge of the G3 grid.
normal
}
......................................................................................................................................................................................................................
Fig. 2-5
– 10 –
KV-SW34M50
RM-W104
R G
B
R
G
B
R
G B
R
B
R
G
G
G
B
R
B
2-2. CONVERGENCE
Before starting this adjustment, adjust the focus,
horizontal size and vertical size.
Receive dot/hatch signal
Pic mode: Personal (PIC 90%, BRIGHTNESS 50%
COLOR 50%, HUE 50%, SHARPNESS 50%).
(1) Horizontal and Vertical Static Convergence
1. (Moving vertically), adjust the V.STAT magnet so that
the red, green and blue dots are on top of each other at
the centre of the screen.
2. (Moving horizontally), adjust the H.STAT VR control so
that the red, green and blue dots are on top of each
other at the center of the screen.
3. If the H.STAT variable resistor cannot bring the red,
green and blue dots together at the center of the
screen, adjust the horizontal convergence with the
H.STAT variable resistor and the V.STAT magnet in the
manner given below.
(In this case,the H.STAT variable resistor and the
V.STAT magnet influence each other so be sure to
perform adjustments while tracking).
4. BMC (Hexapole) Magnet.
If the red, green and blue dots are not balanced or
aligned, then use the BMC magnet to adjust in the
manner described below.
H. STAT VR
V. STAT
Magnet
RV705
H. STAT
RV1800
SCREEN (G2)
C Board
Center dot
R     G     B
G
R
B
a
a
b
b
b
R
R
G
G
B
B
a
b
R
R
G
G
B
B
1
V. STAT
2
H. STAT VR
R
R
G
G
B
B
a
a
b
b
b
R
R
G
G
B
B
a
b
3
H. STAT
R
R
G
G
B
B
a
a
b
b
b
Purity
BMC
BMC (Hexapole)
Purity
DY pocket
V.STAT
V.STAT
4
BMC (Hexapole) Magnet
5. Operation of V.STAT magnet
If the V.STAT magnet is moved in the "a" and "b" arrows,
the red, green and blue dots moves as shown below.
6. Moved RV705 H.STAT.
the red, green an blue dots move as shown below.
– 11 –
KV-SW34M50
RM-W104
(2) Dynamic Convergence Adjustment
Preparation:
Before starting this adjustment, adjust the horizontal  and
the vertical static convergence
7. Y separation axis correction magnet adjustment.
1. Receive the cross-hatch signal and adjust
[PICTURE] to [MIN] and [BRIGHTNESS] to
[STANDARD]  .
2. Adjust the Y separation axis correction magnet on
the neck assembly so that the horizontal lines at
the top and bottom of the screen are straight.
Neck assy
Neck assy
Red
Blue
Red
Blue
VM board
VM board
R B
R B
TLH
TLV
YCH
XCV
B
R
R
B
(VR1) H-TRAP
DY pocket
(XCV)
DY pocket
TLH Plate
(VR3)
TLV
(XCV)
(VR2)
YCH
ON DY:
(3) Screen-corner Convergence
If you are unable to adjust the corner convergence
properly, this can be corrected with the use Permaloy
Assy Correction or Piece (B) 120, CONV, CORRECT
1. Affix the  Permaloy Assy Correction or Piece (B) 120,
CONV, CORRECT corresponding to the misconverged
areas.
TLV
Rotate TLV-2 VOL (29", 34") on DY
XCV
Rotate XCV
Adj core on DY
YCH
Rotate YCH
VOL on DY
TLH
Insert
TLH
Correction Plate to DY Pocket
(Left or Right)
b
a
c
d
a-d : screen-corner
        misconvergence
a
b
c
d
a to d : Permaloy Assy Correction or Piece
(B) 120, CONV, CORRECT 
Fix a Permaloy Assy Correction or Piece (B) 
120, CONV, CORRECT to the misconverged areas 
2-3. Terrestrial Magnetism Correction Checking
(For 34" Except ME & MEE (Saudi)
1. Disconnect the Relay connection from the Landing
Correction Coil Wire.
2. Perform Landing check.
3. Receive 'RED' Signal.
4. Set Horizontal Magnetic field to "0". Then degauss the
CRT screen.
5. Change Horizontal Magnetic field to "SOUTH" direction.
i.
Set picture Rotation "–" maximum
ii. Connect the Relay connection, from the Landing
Correction Coil Wire, mislanding should be improved.
6. Otherwise, please check whether
i.
Landing Correction coil/reverse opposite position.
ii. Landing Correction Coil Connector connected
wrongly.
– 12 –
KV-SW34M50
RM-W104
2-5. G2 (SCREEN) ADJUSTMENTS
1. Set the  PICTURE to Normal.
2. Go to Service mode. Set WHBL 016 RGBB bit to 01.
3.  Connect R,G,B of the  C board cathode to the
oscilloscope.
4. Adjust cathode voltage to the value below.
5. Adjust G2 (screen) on the FBT until picture shows the
point before cut off.
Cathode setting voltage:
170 V 
± 2 (VDC)
2-4. FOCUS ADJUSTMENT
FOCUS adjustment should be completed before W/B
adjustment.
1. Receive digital monoscope pattern.
2. Set "Picture Mode" to "DYNAMIC". (Multi), Set "Picture
Mode to Vivid (NTSC).
3. a) Adjust focus VR so that the center of screen
becomes just focus (28", 29",32",34").
b) Adjust focus VR so that the lion teeth
becomes just focus (25").
4. Change the receiving signal to white pattern and blue
back.
5. Confirm Magenta ring is not noticeable. In case
magenta ring is obvious, adjust FOCUS VR to balance
between MAGENTA RING and FOCUS.
2-6. WHITE BALANCE ADJUSTMENT
1. Set to Service Mode (Refer Section 3-1:
ADJUSTMENTS WITH COMMANDER).
2. Input white raster signal.
3. Set Picture to DYNAMIC. Intelligent Picture: ON.
i. For SA & SR set OPTB 006 OPB 6 to 00.
4. Select WHBL 002"RDRV" and adjust the value to 37
5. Select WHBL 003"GDRV" and 004 "BDRV"and adjust
the data for the best white balance in highlight condition.
6. Adjust WHBL 000 "BKOR" and 001 "BKOG"and adjust
the data for best white balance cut-off condition.
7. Write into the memory by pressing [MUTING] then 
-
.
8. Write offset data for other mode.
After adjustment, please reset:
i. OPTM 006 – OPB 6 to original data (SA & SR series).
Adjust
Offset
Offset
18000
t 12363 t 9300
BKOR
–2
–3
BKOG
+1
+2
RDRV
0
0
GDRV
–3
–8
BDRV
–8
–18
2-7. SUB BRIGHT ADJUSTMENT
1. Set to service mode.
2. Brightness set to 50%, Picture: Minimum.
3. Select WHBL 010 SBRT with 
1
 and 
4
, and adjust
'SBRT' data with 
3
 and 
6
 so that the third stripe from
right dimly lit.
4. Write into the memory by pressing [MUTING] then 
-
.
5. Models cut-off: 10 IRE
Slightly Glimmer: 20 IRE + 2 steps
FLYBACK TRANSFORMER  (T506)
Focus
Screen
7. Confirm mislanding area becomes smaller
8. Landing check
LCC= Landing Correction Coil
BH= 40
LCC
SIGNAL
DIRECTION
ON
RED
 South, North
ON
BLUE
South, North
ON
RED
West, East
ON
BLUE
West, East
RED
GREEN
Blue