– 5 –
KV-HV21F50/HV21F53
   RM-GA002
2
 Rear cover
1
Eight screws
(+BVTP 4 × 16 
TYPE 2 IT-3)
2 Rear cover
1 3D Speaker box assy
(KV-HV21F53)
1
Two screws
(WH DIA. 16) 
(+P 4 × 16)
SECTION 1
DISASSEMBLY
2
 
Terminal 
     bracket
3
One screw
(+BVTP 4 x 16
TYPE 2 IT-3)
1
 
One screw
(+BVTP 3 x 12
TYPE 2 IT-2)
1-2.
REAR COVER REMOVAL
1.1
3D SPEAKER REMOVAL
1-4.
CHASSIS ASSY REMOVAL
1-3.
SPEAKER REMOVAL
1-6.
TERMINAL BRACKET REMOVAL
1-5.
SERVICE POSITION
– 6 –
KV-HV21F50/HV21F53
   RM-GA002
1
J Board (KV-HV21F53) 
Two screws (+BVTP 3x12 TYPE 2 IT-3)
A Board
1-8.
A BOARD REMOVAL
1-7.
J BOARD REMOVAL
1-9.
PICTURE TUBE  REMOVAL
Note:
• Please make sure the TV set is not in standing position before removing necessary CRT support located on bottom
right and left.
1) Place the TV set with the CRT face down on a cushion jig.
2) Remove the rear cover.
3) Unplug all under connecting leads from the Deflection Yoke, Degaussing Coil and CRT grounding strap.
qs
 Degaussing Coil
4
 Anode Cap Removal
5
 C Board Removal
8
 Chassis Assy Removal
9
 Support, CRT(2) Removal
6
Loosen the Neck Assembly
fixing screw and removal
q;
Holder, DGC(2) 
Removal
qf
 DGC(2) Removal
qa
Spring Tension (2)
Removal
qg
 Screw(5) Tapping
qd
 Earth Coating Assy
7
Loosen the Deflection Yoke
fixing screw and remove
– 7 –
KV-HV21F50/HV21F53
   RM-GA002
• REMOVAL OF ANODE-CAP
Note:
• After removing the anode, short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT
shield or carbon paint on the CRT.
REMOVING PROCEDURES
1
Turn up one side of the rubber cap in the direction
indicated by the arrow 
A.
2
Using a thumb pull up the rubber cap firmly in the di-
rection indicated by the arrow 
B.
3
When one side of the rubber cap is separated from
the anode button,  the anode-cap can be removed by
turning up the rubber cap and pulling it up in the
direction of the arrow 
C.
HOW TO HANDLE AN ANODE-CAP
1
Do not damage the surface of anode-caps with
sharp shaped objects.
2
Do not press the rubber too hard so as not to
damage the inside of anode-cap.
A metal fitting called the shatter-hook terminal is
built into the rubber.
3
Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage
the rubber.
anode button
a
a
b
b
c
– 8 –
KV-HV21F50/HV21F53
   RM-GA002
The following adjustments should be made when a complete
realignment is required or a new picture tube is installed.
The controls and switch should be set as follows unless
otherwise noted:
Picture control ......................................................... NORMAL
Brightness control ................................................... NORMAL
Perform the adjustments in order as follows:
1. Beam Landing
2. Convergence
3. Focus
4. G2 (SCREEN)
5. White Balance
Note: Test Equipment Required
1. Pattern Generator
2. Degausser
3. DC Power Supply
4. Digital Multimeter
SECTION 2
SET-UP ADJUSTMENTS
Preparation :
• Feed in the white pattern signal.
• Before starting, degauss the entire screen with the
degausser.
• In order to reduce the geomagnetism on the set's
picture tube, face it east or west.
2-1. BEAM LANDING ADJUSTMENT
1. Input a raster signal with the pattern generator.
2. Loosen the deflection yoke mounting screw, and set the
purity control to the center as shown below.
3. Set the raster signal of the pattern generator to green.
4. Move the deflection yoke (DY) backward and adjust the
purity control so that green is in the center and blue and
red are at the sides evenly.
5. Then move the DY forward and adjust so that the entire
screen becomes green.
6. Now switch over raster signal to red then blue and
confirm the condition.
...................................................................................................................................................................................................................... ...........
5. Oscilloscope
6. Landing Checker
7. XCV Adjuster
Purity control
Red
Blue
Green
7. When the position of the DY is determined, tighten it
with the DY mounting screw.
8. If the beam does not land correctly in all corners of the
screen, use magnet disc to correct it.
2-2. CONVERGENCE ADJUSTMENT
Preparation :
• Before starting, perform FOCUS adjustment.
• Picture mode STANDARD.
• Receive dot/cross hatch pattern.
a) Vertical Static Convergence
Purity control
corrects this area.
Disk magnets or rotatable
disk magnets correct these
areas (a-d).
Deflection yoke positioning
corrects these areas.
a
b
b
c
c
d
d
a
Center dot
R    G    B
R
G
B
4 pole magnet
RV750
H. STAT