– 6 –
KV-BZ212M10/M71/N50/P50
   RM-GA002
• REMOVAL OF ANODE-CAP
Note:
• After removing the anode, short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or
carbon paint on the CRT.
• REMOVING PROCEDURES
Turn up one side of the rubber cap in the direction
indicated by the arrow 
A.
Using a thumb pull up the rubber cap firmly in the direction
indicated by the arrow 
B.
When one side of the rubber cap is separated from the
anode button,  the anode-cap can be removed by turning
up the rubber cap and pulling it up in the direction of the
arrow 
C.
• HOW TO HANDLE AN ANODE-CAP
Do not damage the surface of anode-caps with sharp
shaped objects.
Do not press the rubber too hard so as not to damage
the inside of anode-cap.
A metal fitting called the shatter-hook terminal is built
into the rubber.
Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage the
rubber.
A
A
B
B
C
 Anode Button
1-7.
PICTURE TUBE  REMOVAL
Note:
• For KV-BZ212M10, this picture tube is upside down and the position for the anode cap and tension springs are change
accordingly.
• Please make sure the TV set is not in standing position before removing necessary CRT support located on bottom right
and left.
1) Remove the Rear Cover.
2) Unplug all interconnecting leads from the Deflection Yoke, Neck Assy, Degaussing Coils and CRT grounding strap. Remove
Chassis Assy.
3) Place the TV set with the CRT face down on a cushion (jig).
qa
 Earth Coating Assy
4
 Anode Cap Removal
8
 Band, DGC Removal
5
 C Board Removal
qd
 Spring Tension(x2) Removal
qf
 Screw Tapping 7+ Crown Washer (x4)
q;
 Degaussing Coil
6
 Loosen the Neck Assembly
 
fixing screw and remove
 neck 
Assy
7
 Loosen the Deflection Yoke
 
fixing screw and remove
9
 Holder, DGC Removal (x2)
qs 
Supports, CRT
 Removal 
(x2)
– 7 –
KV-BZ212M10/M71/N50/P50
   RM-GA002
The following adjustments should be made when a complete
realignment is required or a new picture tube is installed.
The controls and switch should be set as follows unless
otherwise noted:
Picture control ......................................................... NORMAL
Brightness control ................................................... NORMAL
Perform the adjustments in order as follows:
1. Beam Landing
2. Convergence
3. Focus
4. G2 (SCREEN)
5. White Balance
Note: Test Equipment Required
1. Pattern Generator
2. Degausser
3. DC Power Supply
4. Digital Multimeter
SECTION 2
SET-UP ADJUSTMENTS
Preparation :
• Feed in the white pattern signal.
• Before starting, degauss the entire screen with the
degausser.
• In order to reduce the geomagnetism on the set's
picture tube, face it east or west.
2-1. BEAM LANDING ADJUSTMENT
1. Input a raster signal with the pattern generator.
2. Loosen the deflection yoke mounting screw, and set the
purity control to the center as shown below.
3. Set the raster signal of the pattern generator to green.
4. Move the deflection yoke (DY) backward and adjust the
purity control so that green is in the center and blue and
red are at the sides evenly.
5. Then move the DY forward and adjust so that the entire
screen becomes green.
6. Now switch over raster signal to red then blue and
confirm the condition.
...................................................................................................................................................................................................................... ...........
5. Oscilloscope
6. Landing Checker
7. XCV Adjuster
Purity control
Red
Blue
Green
7. When the position of the DY is determined, tighten it
with the DY mounting screw.
8. If the beam does not land correctly in all corners of the
screen, use magnet disc to correct it.
2-2. CONVERGENCE ADJUSTMENT
Preparation :
• Before starting, perform FOCUS adjustment.
• Picture mode STANDARD.
• Receive dot/cross hatch pattern.
a) Vertical Static Convergence
a
b
b
c
c
d
d
a
Purity control
corrects this area.
Disc magnets or rotatable
disc magnets correct these
areas (a-d).
Deflection yoke positioning
corrects these areas.
4 pole magnet
RV705
H. STAT
RV1800
G2 (SCREEN) 
Center dot
R     G     B
G
R
B
– 8 –
KV-BZ212M10/M71/N50/P50
   RM-GA002
1. (Moving vertically), adjust the 4 pole magnet to converge
red, green and blue dots in the center of the screen.
2. Tilt the 4 pole magnet and adjust static convergence to
open or close the 4 pole magnet.
3. When the 4 pole magnet is moved in the direction of
arrow A and B, the red, green and blue dots moves as
shown below:
Moved RV750 (H.STAT)
b) Horizontal Static Convergence
If the blue dots does not converge with the red and green
dots, use the 6 pole magnet to adjust in the manner
described below.
R
R
G
G
B
B
A
B
B
A
R G
B
R
G
B
R
G B
R
B
R
G
G
G
B
R
B
6 Pole Magnet
4 pole Magnet
DY pocket
Purity
6 Pole
Magnet
4 Pole
Magnet
c) Convergence Rough Adjustment
Preparation :
• Before starting this adjustment, adjust the horizontal
and vertical static convergence.
Input cross hatch pattern.
i)
TLH
Adjust the horizontal convergence of red and blue dots
by inserting TLH Correction Plate to the DY pocket (left
or right).
ii)
YCH
Adjust YCH to balance Y axis.
iii) TLV
Adjust the vertical convergence of red and blue dots.
iv) XCV
Adjust XCV to balance X-axis.
d) Screen Corner Convergence
Affix a Piece A (90), Convergence Correct/Permaloy Assy
Correction to the misconverged areas.
TLV
R B
YCH
R
B
XCV
B
R
TLH
B
R
(VR1)
TLV1 (no need to adjust)
DY pocket
DY pocket
TLH Plate
(VR3)
TLV2
(XCV)
(VR2)
YCH
ON DY:
b
a
c
d
a-d : screen-corner
        misconvergence
a1
b1
c1
d1
a1~d1: Piece A (90), Convergence Correct
or
Permaloy Assy Correction
B
R
G
G
R
B
– 9 –
KV-BZ212M10/M71/N50/P50
   RM-GA002
2-3. FOCUS ADJUSTMENT
FOCUS adjustment should be completed before W/B
adjustment.
1. Receive digital monoscope pattern.
2. Set Picture Mode to "DYNAMIC".
3. Adjust focus VR to obtain a just focus at the center of
the screen.
4. Change the receiving signal to white pattern and blue
back.
5. Confirm magenta ring is not noticeable. In case magenta
ring is obvious, then adjust FOCUS VR to balance
magenta ring and FOCUS.
2-4. G2 (SCREEN) ADJUSTMENT
1. Set the following condition:
– Picture and Brightness to "STANDARD".
– TV to Video mode.
– WHBL 016 "RGBB" to 01
2. Connect R, G, B of the C/CV board cathode to
oscilloscope.
3. Adjust Brightness to obtain the cathode value to the
value stated below.
4. Adjust SCREEN VR on the FBT until the scanning line
disappears.
5. Finally set WHBL 16 "RGBB" back to 00.
165 
± 2VDC
2-5. WHITE BALANCE ADJUSTMENT
1. Set to Service Mode.
2. Input white raster signal using signal generator.
3. Set the following condition:
Picture "DYNAMIC", PICT 006 "WTS" to 00.
4. At Highlight condition, select WHBL 03 "GDRV" and 04
"BDRV" with 1 and 4 button of the remote
commander then adjust the data with 3 and 6 button.
5. At Cutoff, select WHBL 000 "BKOR" and 001 "BKOG"
and adjust the data.
6. Perform adjustment at Highlight and Cutoff condition
until it reaches its target.
7. Write data into memory by pressing [MUTING] 
t -.
8. Finally set PICT 006 "WTS" back to its original data.
VIVID : 45000K+SMPCD
Center data:
X : 0.2444
Y : 0.2446
Page of 80