– 3 –
KV-BZ212M10/M71/N50/P50
   RM-GA002
The units in this manual contain a self diagnostic function. If an error occurs, the STANDBY (1) indicator will automatically
begin to flash. The number of times the STANDBY (1) indicator flashes translates to a probable source of the problem. If an
error symptom cannot be reproduced, the remote commander can be used to review the failure occurrence data stored in
memory to reveal past problems and how often these problems occur.
1. DIAGNOSTIC TEST  INDICATORS
When an errors occurs, the STANDBY (1) indicator will flash a set number of times to indicate the possible cause of the
problem. If there is more than one error, the indicator will identify the first of the problem areas.
Result for all of the following diagnosis items are displayed on screen. No error has occurred if the screen displays a "0".
SELF DIAGNOSTIC FUNCTION
Diagnosis
Item
Description
No Power
+B overcurrent
(OCP)
V-Protect (OVP)
IK (AKB)
Power supply
NG (+5V) for
Video Processor
No. of timer
STANDBY (1)
indicator flashes
Does not light
2 times
4 times
5 times
8 times
Diagnostic Result
on screen display
2:0
or
2:1 ~ 255
4:0
or
4:1 ~ 255
5:0
or
5:1 ~ 255
8:0
or
8:1 ~ 255
Probable Cause
Location
• Power cord is not plugged
in.
• Fuse is burned out (F600)
A board.
• H OUT (Q805) is shorted.
(A board)
• IC751 is shorted. (C board)
• +13V is not supplied.
(A board)
• IC804 is faulty. (A board)
• Video OUT (IC751) is
faulty. (C board)
• IC001 is faulty. (A board)
• Screen (G2) is improperly
adjusted.
• IC604 faulty.
• IC602 faulty.
Detected
Symptoms
• Power does not turn on.
• No power is supplied on TV.
• AC Power supply is faulty.
• Power does not turn on.
• Load on power line is shorted.
• Has entered standby state
after horizontal raster.
• Vertical deflection pulse is
stopped.
• Power line is shorted or
power supply is shorted.
• No raster is generated.
• CRT Cathode current
detection reference pulse
output is small.
• No power supply to CRT
ANODE.
• No RASTER is generated.
2. STANDBY INDICATOR BLINKING PROCESS
The example above represents for 4 times blink
Lamp OFF 3 seconds 
Lamp ON 300ms
Lamp OFF 300ms
3. STANDBY INDICATOR ON TV FRONT PANEL
Standby indicator
– 4 –
KV-BZ212M10/M71/N50/P50
   RM-GA002
[+B overcurrent $OCP%]
Occurs when an overcurrent on the +B(135V) line is detected by pin 32 of IC001 (A board).
If the voltage of pin 32 of IC001 (A board) is more than 4V, the unit will automatically go to
standby.
[V-PROTECT]
Occurs when an absence of the vertical deflection pulse is detected by pin 13 of IC001
(A board).
[IK $AKB%]
If the RGB levels* do not balance within 15 sec after the power is turned on, this error will be
detected by IC001 (A board). TV will stay on, but there will be 5 times LED blinking.
Occurs when IC001 internal HV protect detects an abnormal H-Pulse (frequency) due to
improper power supply to IC001. TV cuts off high voltage power of anode CRT. No picture will be
detected. eg: IC602, IC604 go faulty.
* (Refers to the RGB levels of the AKB detection Ref pulse that detects IK.)
POWER SUPPLY NG (+5V)
for VIDEO PROCESSOR
4. SELF DIAGNOSTIC SCREEN DISPLAY
5. HANDLING SELF DIAGNOSTIC SCREEN DISPLAY
6. SELF-DIAGNOSTIC CIRCUIT
5
8
No.
Description
Method
1.
Display self diagnostic screen
[Display] t [Channel    ] t [Volume    ] t [Power / TV]
Note: The above must be performed while TV is on standby mode.
2.
Stop standby flash
i) Turn off power switch on main.
ii) Unplug power cord from the outlet.
3.
Clear fault result
[Channel    ] t 
-
Note: Diagnostic results display on screen is not automatically cleared. Therefore,
clear result after completion of repair.
4.
Quit self diagnostic screen
Turn off power switch of remote commander or main unit.
2 OCP 
:  0
3 OVP 
:
N/A
4 VSTOP  :
1
5 AKB 
:
0
8 SUP 
:
0
101 WDT :  N/A
"0" means no fault has been detected.
"1" means a fault has been detected.
"2" means two faults have been detected.
"N/A" means not available for this models.
SELF DIAGNOSTIC
A BOARD
IC001
Y/CHROMA JUNGLE
A BOARD
IC804
V.OUT
A BOARD
IC001
SYSTEM
A BOARD
IC003
MEMORY
FROM
C BOARD
IC751 PIN 5
IK
EHTO
RED LED
DISPLAY
SDA0
V.GUARD
SDA
5
F.B-PLS
3
13
84
32
122
A BOARD
FROM
Q816
COLLECTOR
109
– 5 –
KV-BZ212M10/M71/N50/P50
   RM-GA002
1 Seven screws
     (+BVTP 4 
× 16)
2 Rear cover
SECTION 1
DISASSEMBLY
1-2.
SPEAKER REMOVAL
1-1.
REAR COVER REMOVAL
1-4.
SERVICE POSITION
1-3.
CHASSIS ASSY REMOVAL
1-6.
A BOARD REMOVAL
1
 Four screws
     (+P4x16)
A Board
1-5.
TERMINAL BRACKET REMOVAL
1
 One screw
 (+BVTP 
× 12
 Type2 
IT-3)
2
 Terminal bracket
3
 Two screws
 (+BVTP 
× 12
 Type2 
IT-3)
– 6 –
KV-BZ212M10/M71/N50/P50
   RM-GA002
• REMOVAL OF ANODE-CAP
Note:
• After removing the anode, short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or
carbon paint on the CRT.
• REMOVING PROCEDURES
Turn up one side of the rubber cap in the direction
indicated by the arrow 
A.
Using a thumb pull up the rubber cap firmly in the direction
indicated by the arrow 
B.
When one side of the rubber cap is separated from the
anode button,  the anode-cap can be removed by turning
up the rubber cap and pulling it up in the direction of the
arrow 
C.
• HOW TO HANDLE AN ANODE-CAP
Do not damage the surface of anode-caps with sharp
shaped objects.
Do not press the rubber too hard so as not to damage
the inside of anode-cap.
A metal fitting called the shatter-hook terminal is built
into the rubber.
Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage the
rubber.
A
A
B
B
C
 Anode Button
1-7.
PICTURE TUBE  REMOVAL
Note:
• For KV-BZ212M10, this picture tube is upside down and the position for the anode cap and tension springs are change
accordingly.
• Please make sure the TV set is not in standing position before removing necessary CRT support located on bottom right
and left.
1) Remove the Rear Cover.
2) Unplug all interconnecting leads from the Deflection Yoke, Neck Assy, Degaussing Coils and CRT grounding strap. Remove
Chassis Assy.
3) Place the TV set with the CRT face down on a cushion (jig).
qa
 Earth Coating Assy
4
 Anode Cap Removal
8
 Band, DGC Removal
5
 C Board Removal
qd
 Spring Tension(x2) Removal
qf
 Screw Tapping 7+ Crown Washer (x4)
q;
 Degaussing Coil
6
 Loosen the Neck Assembly
 
fixing screw and remove
 neck 
Assy
7
 Loosen the Deflection Yoke
 
fixing screw and remove
9
 Holder, DGC Removal (x2)
qs 
Supports, CRT
 Removal 
(x2)
Page of 80
Display

Sony KV-BZ212M10 Service Manual ▷ Download

  • DOWNLOAD Sony KV-BZ212M10 Service Manual ↓ Size: 8.48 MB | Pages: 80 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sony KV-BZ212M10 in PDF for free, which will help you to disassemble, recover, fix and repair Sony KV-BZ212M10 TV. Information contained in Sony KV-BZ212M10 Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.