– 5 –
KV-BM14M70/BM14P42/P42/L/P42/V
RM-W101
STANDBY indicator
2. DISPLAY OF 
STANDBY (1)
 INDICATOR
FLASH COUNT
3. STOPPING THE 
STANDBY (1)
 INDICATOR FLASH
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY (1)
indicator from flashing.
4. SELF-DIAGNOSTIC SCREEN DISPLAY
For errors with symptoms such as "power sometimes shuts off" or "screen sometimes goes off" that cannot be confirmed,
it is possible to bring up past occurrences of failure on the screen for confirmation.
[To Bring Up Screen Test]
In standby mode, press buttons on the remote commander sequentially in rapid succession as shown below:
Display 
/ Channel 5 / Volume 
/ Power 
 / TV 
˘
Note that this differs from entering the service mode (volume [+]).
The following screen will be displayed indicating the error count.
Diagnostic Item
Flash Count*
+B overcurrent
2 times
V-Protect
4 times
IK (AKB)
5 times
Power Supply NG (+5V)
8 times
for Video processor
* One flash count is not used for self-diagnosis.
2 : 
0
3 :
N/A
4 :
0
5 :
1
8 :
0
101 :
N/A
SELF DIAGNOSTIC
Numeral "0" means that no fault was detected.
Numeral "1" means the number of a fault occurrence (1 ~ 255).
Lamp ON 300ms
Lamp OFF 3 sec.
Lamp OFF 300ms
2 times
4 times
5 times
8 times
– 6 –
KV-BM14M70/BM14P42/P42/L/P42/V
RM-W101
5. HANDLING OF SELF-DIAGNOSTIC SCREEN DISPLAY
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic
screen during repairs. When you have completed the repairs, clear the result display to “0”.
Unless the result display is cleared to “0”, the self-diagnosis function will not be able to detect subsequent faults after
completion of the repairs.
[Clearing the result display]
To clear the result display to “0”, press buttons on the remote commander subsequent as shown below when the
self-diagnostic screen is being displayed.
, -
[Quitting Self-diagnostic screen]
To quit the entire self-diagnostic screen, turn off the power switch on the remote commander or the main unit.
6. SELF-DIAGNOSTIC CIRCUIT
A BOARD
IC001
Y/CHROMA JUNGLE
A BOARD
IC804
V.OUT
A BOARD
IC001
SYSTEM
A BOARD
IC003
MEMORY
FROM
C BOARD
IC751 PIN 5
IK
EHTO
RED LED
DISPLAY
SDA1
V.GUARD
SDA
5
F.B-PLS
3
13
84
32
122
A BOARD
FROM
Q804
COLLECTOR
99
[+B overcurrent $OCP%]
Occurs when an overcurrent on the +B(135V) line is detected by pin 32 of IC001 (A board).
If the voltage of pin 32 of IC001 (A board) is more than 4V, the unit will automatically go
to standby.
[V-PROTECT]
Occurs when an absence of the vertical deflection pulse is detected by pin 13 of IC001
(A board).
[IK $AKB%]
If the RGB levels* do not balance within 15 sec after the power is turned on, this error will
be detected by IC001 (A board). TV will stay on, but there will be 5 times LED blinking.
Occurs when IC001 internal HV protect detects an abnormal H-Pulse (frequency) due to
improper power supply to IC001. TV cuts off high voltage power of anode CRT. No picture
will be detected. eg: IC602, IC604 go faulty.
* (Refers to the RGB levels of the AKB detection Ref pulse that detects IK.)
POWER SUPPLY NG (+5V)
for VIDEO PROCESSOR
– 7 –
KV-BM14M70/BM14P42/P42/L/P42/V
RM-W101
1 Rear cover
2 Six screws
     (+BVTP 4 
× 16)     
1 Four screw
     (+BVTP 4 
× 16)
1 Terminal
     bracket
2 Two screw
     (+BVTP 4 
× 16)
3 One screw
     (+BVTP 3 
× 12)
SECTION 1
DISASSEMBLY
1-2.
SPEAKER REMOVAL
1-3.
CHASSIS ASSY REMOVAL
1-4.
SERVICE POSITION
1-5.
TERMINAL BRACKET REMOVAL
1-6.
A BOARD REMOVAL
1 A board
1-1.
REAR COVER REMOVAL
– 8 –
KV-BM14M70/BM14P42/P42/L/P42/V
RM-W101
• REMOVAL OF ANODE-CAP
Note:
• After removing the anode, short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT
shield or carbon paint on the CRT.
• REMOVING PROCEDURES
1
Turn up one side of the rubber cap in the direction
indicated by the arrow 
A.
2
Using a thumb pull up the rubber cap firmly in the di-
rection indicated by the arrow 
B.
3
When one side of the rubber cap is separated from
the anode button,  the anode-cap can be removed by
turning up the rubber cap and pulling it up in the
direction of the arrow 
C.
• HOW TO HANDLE AN ANODE-CAP
1
Do not damage the surface of anode-caps with
sharp shaped objects.
2
Do not press the rubber too hard so as not to
damage the inside of anode-cap.
A metal fitting called the shatter-hook terminal is
built into the rubber.
3
Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage
the rubber.
anode button
1-7.
PICTURE TUBE  REMOVAL
Note:
• Please make sure the TV set is not in standing position before removing necessary CRT support located on bottom
right and left.
1) Place the TV set with the CRT face down on a cushion jig.
2) Remove the rear cover.
3) Unplug all inder connecting leads from the Deflection Yoke, Degaussing Coil and CRT grounding strap.
0 Earth Coating Assy
qf
 Block Center
4 Anode Cap Removal
qs
 Band, DGC Removal
5 C Board Removal
8 Chassis Assy Removal
9
 Support, CRT(2) Removal
qa
 Spring Tension Removal
qd
 Nut, Special, CRT (4)
6 Loosen the Neck Assembly
fixing screw and remove
7
 Loosen the Deflection Yoke
fixing screw and remove
a
a
b
b
c
Page of 74