Sony KV-AZ212M60 Service Manual ▷ View online
– 5 –
KV-AZ212M60/M81/M83
RM-GA002
1
Two screws
(4x16),
TAPPING,+P
(4x16),
TAPPING,+P
1
Eight screws
(+BVTP 4x16)
Type2 IT-3
(+BVTP 4x16)
Type2 IT-3
2
Rear cover
SECTION 1
DISASSEMBLY
1-2.
SPEAKER REMOVAL
(Except KV-AZ212M83)
1-1.
REAR COVER REMOVAL
1-4.
CHASSIS ASSY REMOVAL
1-3.
SPEAKER REMOVAL (KV-AZ212M83)
1-5.
SERVICE POSITION
1-6.
TERMINAL BRACKET
1
Two screws
(4x16)
Tapping,+P
(4x16)
Tapping,+P
1
Two screws
(+BVTP 4x16
Type2 IT-3)
(+BVTP 4x16
Type2 IT-3)
3
Terminal bracket
1
One screw
(+BVTP 3x12
Type2 IT-3)
2
One screws
(+BVTP 4x16
Type2 IT-3)
– 6 –
KV-AZ212M60/M81/M83
RM-GA002
qd
Screw, Tapping 5+
Crown Washer (x4)
4
Anode Cap Removal
8
Degaussing Coil
6
Loosen the Neck Assembly
fixing screw and remove
Neck Assy
Neck Assy
qa
Loosen the Deflection Yoke
fixing screw and remove
5
CV Board Removal
9
Spring Tension(2)
Removal
7
Holder, DGC
Removal (x2)
0
Earth Coating Assy
qs
Supports, CRT
Removal (x2)
1-8.
PICTURE TUBE REMOVAL
Note:
• Please make sure the TV set is not in standing position before removing necessary CRT support located on bottom right
and left.
1) Remove the Rear Cover.
2) Unplug all interconnecting leads from the Deflection Yoke, Neck Assy, Degaussing Coils and CRT grounding strap. Remove
2) Unplug all interconnecting leads from the Deflection Yoke, Neck Assy, Degaussing Coils and CRT grounding strap. Remove
Chassis Assy.
3) Place the TV set with the CRT face down on a cushion (jig).
A Board
1-7.
A BOARD REMOVAL
– 7 –
KV-AZ212M60/M81/M83
RM-GA002
C
Anode Button
B
B
A
A
• REMOVAL OF ANODE-CAP
Note:
• After removing the anode, short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield
or carbon paint on the CRT.
•
REMOVING PROCEDURES
1 Turn up one side of the rubber cap in the direction
indicated by the arrow a.
2 Using a thumb pull up the rubber cap firmly in the direction
indicated by the arrow b.
3 When one side of the rubber cap is separated from the
anode button, the anode-cap can be removed by turning
up the rubber cap and pulling it up in the direction of the
arrow c.
up the rubber cap and pulling it up in the direction of the
arrow c.
•
HOW TO HANDLE AN ANODE-CAP
1 Do not damage the surface of anode-caps with sharp
shaped objects.
2 Do not press the rubber too hard so as not to damage
the inside of anode-cap.
A metal fitting called the shatter-hook terminal is built
into the rubber.
A metal fitting called the shatter-hook terminal is built
into the rubber.
3 Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage the
rubber.
rubber.
– 8 –
KV-AZ212M60/M81/M83
RM-GA002
The following adjustments should be made when a complete
realignment is required or a new picture tube is installed.
realignment is required or a new picture tube is installed.
The controls and switch should be set as follows unless
otherwise noted:
otherwise noted:
Picture control ......................................................... NORMAL
Brightness control ................................................... NORMAL
Brightness control ................................................... NORMAL
Perform the adjustments in order as follows:
1. Beam Landing
2. Convergence
3. Focus
4. G2 (SCREEN)
5. White Balance
1. Beam Landing
2. Convergence
3. Focus
4. G2 (SCREEN)
5. White Balance
Note: Test Equipment Required
1. Pattern Generator
2. Degausser
3. DC Power Supply
4. Digital Multimeter
1. Pattern Generator
2. Degausser
3. DC Power Supply
4. Digital Multimeter
SECTION 2
SET-UP ADJUSTMENTS
Preparation :
• Feed in the white pattern signal.
• Before starting, degauss the entire screen with the
• Feed in the white pattern signal.
• Before starting, degauss the entire screen with the
degausser.
• In order to reduce the geomagnetism on the set's
picture tube, face it east or west.
2-1. BEAM LANDING ADJUSTMENT
1. Input a raster signal with the pattern generator.
2. Loosen the deflection yoke mounting screw, and set the
2. Loosen the deflection yoke mounting screw, and set the
purity control to the center as shown below.
3. Set the raster signal of the pattern generator to green.
4. Move the deflection yoke (DY) backward and adjust the
4. Move the deflection yoke (DY) backward and adjust the
purity control so that green is in the center and blue and
red are at the sides evenly.
red are at the sides evenly.
5. Then move the DY forward and adjust so that the entire
screen becomes green.
6. Now switch over raster signal to red then blue and
confirm the condition.
...................................................................................................................................................................................................................... ...........
5. Oscilloscope
6. Landing Checker
7. XCV Adjuster
6. Landing Checker
7. XCV Adjuster
Purity control
Red
Blue
Green
7. When the position of the DY is determined, tighten it
with the DY mounting screw.
8. If the beam does not land correctly in all corners of the
screen, use magnet disc to correct it.
2-2. CONVERGENCE ADJUSTMENT
Preparation :
• Before starting, perform FOCUS adjustment.
• Picture mode STANDARD.
• Receive dot/cross hatch pattern.
• Before starting, perform FOCUS adjustment.
• Picture mode STANDARD.
• Receive dot/cross hatch pattern.
a) Vertical Static Convergence
Purity control
corrects this area.
corrects this area.
Disc magnets or rotatable
disc magnets correct these
areas (a-d).
disc magnets correct these
areas (a-d).
Deflection yoke positioning
corrects these areas.
corrects these areas.
a
b
b
c
c
d
d
a
Center dot
R G B
R
G
B
4 pole magnet
RV750
H. STAT
H. STAT
C/CV Board
Click on the first or last page to see other KV-AZ212M60 service manuals if exist.