– 9 –
KV-AR29T80C/AR29X80C
RM-W104
RM-W104
2-11.
REMOVAL OF ANODE-CAP
NOTE : After removing the anode, short circuit the anode of the picture tube and
the anode cap to the metal chassis, CRT shield or carbon paint on the
CRT.
REMOVING PROCEDURES
Do not damage the surface of anode-caps with sharp shaped objects.
Do not press the rubber too hard so as not to damage the inside of anode-cap.
A metal fitting called the shatter-hook terminal is built into the rubber.
Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage the rubber.
• HOW TO HANDLE AN ANODE-CAP
When one side of the rubber cap is separated from the anode button,  the anode-cap
can be removed by turning up the rubber cap and pulling it up in the direction of the
arrow 
c.
Using a thumb pull up the rubber cap firmly in the direction indicated by the arrow b.
Turn up one side of the rubber cap in the direction indicated by the arrow a.
a
a
b
b
c
– 10 –
KV-AR29T80C/AR29X80C
RM-W104
RM-W104
2-12.
CRT
      NOTE: After removing the anode, short circuit the anode of the picture tube
and the anode cap to the metal chassis, CRT shield or carbon paint
on the CRT.
6
 Two screws
    tapping 7 +crown washer
6
 Two screws
    tapping 7 +crown washer
7
 Two CRT supporters
Bezel assembly
3
 Springs with ground wires
8
 CRT
1
 DGC clip
5
 Deflection Yoke
4
 Neck assembly
2
 Degauss coil
– 11 –
KV-AR29T80C/AR29X80C
RM-W104
RM-W104
TV
1
2
3
4
6
7
8
9
0
5
MENU
PROG
A/B
RESET
3. The SCREEN displays the item being adjusted.
4. Press 1 or 4 on the Remote Commander to select the
adjustment item.
5. Press 3 or 6 on the Remote Commander to change the data.
6. Press 2 or 5 on the Remote Commander to select the
category.
 7. If you want to recover the latest values press  7  then  - to read
the memory.
 8. Press [ MUTING ] then  - to write into memory.
 9. Turn power off.
Note: Press 8 then - on the Remote Commander to initialize
or turn set off and on to exit.
3-3.
MEMORY WRITE CONFIRMATION METHOD
 1. After adjustment, turn power off with the remote commander.
 2. Turn  power on and set to Service Mode.
 3. Call the adjusted items again and confirm they were adjusted.
3-1.
METHOD OF SETTING THE SERVICE ADJUSTMENT
MODE
 SERVICE MODE PROCEDURE
 1. Standby mode. (Power off)
 2.            
n   5   n             (+)   n    =/1
on the Remote Commander.
(Press each button within a second.)
3-2.
SERVICE MODE ADJUSTMENT
3-4. ADJUSTING BUTTONS AND INDICATOR
RM-W104
Adjustment item up
Category up
Data up
Data down
Category down
Data
SOFT WARE VERSION ________ 1. PAL
H-PARALLEL
 31
H-BOW 31
H-SHIFT  
 
31
H-WIDTH
 31
H-PARABOLA  31
H-U.CORNER  31
H-L.CORNER
 31
H-TRAPE
 31
Item NO.(register name)
Adjustment item down
SECTION 3
SERVICE MODE
        (+)
%
  =/1
-
Read
– 12 –
KV-AR29T80C/AR29X80C
RM-W104
RM-W104
AP
No.
Name
0
SUBV S-OFF
0 -  3
02
1
SUBV S-SIMU
0 -  3
02
2
SUBV S-ON
0 -  3
00
3
BASS
0 - 15
*1
4
TREBLE
0 -  7
*1
5
SURROUND
1 - 2
*1
Standards *1
PERSONAL
TV-DYNAMIC
TV-DRAMA
TV-SOFT
AV-DYNAMICE
AV-DRAMA
AV-SOFT
3
BASS
7
12
10
9
12
10
9
4
TREBLE
3
6
5
4
6
5
4
Sub volume surround on
Bass control
Treble control
Surround control
Function
Remarks
Standards
No.
ITEM
Functionality
Range
Standards
Sub volume surround off
Sub volume stereo
3-5.SERVICE LIST
DEF1
No.
Name
50Hz
60Hz
0
H-PARALLEL
0 - 63
15
15
Horizontal parallelogram
1
H-BOW
0 - 63
1B
19
Horizontal bow
2
H-SHIFT
0 - 63
25
2C
Horizontal shift
3
H-WIDTH
0 - 63
2A
2A
EW width
4
H-PARABOLA
0 - 63
15
18
EW parabola
5
H-U.CORNER
0 - 63
19
1F
EW upper corner parabola
6
H-L..CORNER
0 - 63
16
1D
EW lower corner parabola
7
H-TRAPE
0 - 63
28
29
EW trapezium
Remarks
Functionality
Standards
Range
Function
DEF2
No.
Name
50Hz
60Hz
0
V-SLOPE
0 - 63
2B
2B
Vertical slope
1
V-AMPL..
0 - 63
38
3C
Vertical amplitud
2
V-S.CORR
0 - 63
1C
24
Vertical s correction
3
V-SHIFT
0 - 63
20
20
Vertical shift
Remarks
Functionality
Range
Standards
Function
OP0
No.
Name
0
FMWS
0 / 1
1
IF AGC SPEED
NORM / 0.7
◊NORM /
3
◊NORM / 6◊NORM
83
2
Blue SCREEN
1 / 0
83
3
FOAB
NORM/SLOW/SLOW
FAST/FAST
83
4
FORFS
LAST FIELD
FREQUENCY/ATUO
50HZ IF NO SYNC/AUTO
60HZ IF NOSYNC/60HZ
83
5
RP010
1:1.8/1:1/1:1.25/1:1.5
BE
6
EVG
OK/NO
BE
7
DSK
DYNAMIC SKIN
OFF/DYNAMIC SKIN ON
0F
8
HCO
EHT ON VERTICAL/EHT
ON VERT. AND HORI.
0F
Remarks
Functionality
Range
Standards
Function
Page of 49