DOWNLOAD Sony KV-AR292M50 Service Manual ↓ Size: 13.44 MB | Pages: 127 in PDF or view online for FREE

Model
KV-AR292M50
Pages
127
Size
13.44 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
kv-ar292m50.pdf
Date

Sony KV-AR292M50 Service Manual ▷ View online

– 5 –
KV-AR292M50/AR292M81
RM-W102
5. HANDLING OF SELF-DIAGNOSTIC SCREEN DISPLAY
Since the diagnosis results displayed on the screen are not automatically cleared, always check the self-diagnostic screen
during repairs. When you have completed the repairs, clear the result display to "0".
Unless the result display is cleared to "0", the self-diagnosis function will not be able to detect subsequent faults after
completion of the repairs.
[Clearing the result display]
To clear the result display to "0", press buttons on the remote commander sequentially when the self-diagnostic screen is
displayed, as shown below:
Channel [8]
/ "0"
[Quitting Self-diagnostic screen]
To quit the entire self-diagnostic screen, turn off the power switch on the remote commander or the main unit.
6. SELF-DIAGNOSIS CIRCUIT
[+B overcurrent OCP ]
Occurs when an overcurrent on the +B (135V) line is detected by pin 97 of IC001
(A Board). If the voltage of pin 97 of IC001 (A Board) is less than 1V when V.SYNC is
more than HV, the unit will automatically go to standby.
[I-Port]
Occurs when an absence of the vertical deflection pulse is detected by pin 116 of
IC001 (A Board).
[IK $AKB%]
If the RGB levels* do not balance within 15 sec after the power is turned on, this error
will be detected by IC001 (A Board). TV will stay on, and indicalor will start to Blink 5
times.
[HV Protect]
Occurs when IC001 internal HV protect detects an abnormal. H-Pulse (frequency) due
to unproper power supply to IC001. TV cuts off high voltage power of anode CRT. No
picture will be detected eg IC607, IC604 go faulty.
* (Refers to the RGB levels of the AKB detection Ref pulse that detects 1K)
A BOARD
IC001
Y/CHROMA JUNGLE
A BOARD
IC503
V.OUT
A BOARD
IC001
SYSTEM
A BOARD
IC003
MEMORY
FROM
C BOARD
IC751 PIN 5
IK
EHTO
RED LED
DISPLAY
SDA1
V.GUARD
SDA
5
F.B-PLS
3
116
45
97
7
A BOARD
FROM
Q511
COLLECTOR
20
– 6 –
KV-AR292M50/AR292M81
RM-W102
1 Two screws
(+BVTP 4 × 16)
2 Two screws
(Washer Head)
(+P4 × 16)
1 Two hooks 
4 One screw
(+BVTP 3 x 12)
2 F Board
3 BC Board
1 One screw
 
(+BVTP 3 × 12
 
Type2 IT-3)
2 Two hooks 
6 One screw
 
(+BVTP 3 × 12
 
Type2 IT-3)
7 J1 board
5 Terminal bracket
3 One screw
 
(+BVTP 4 × 12
 
Type2 IT-3)
4 Two screws
 
(+BVTP 3 × 12
 
Type2 IT-3)
1 Nine screws
 
(+BVTP 4 × 16
 
Type2 IT-3)
2 Rear cover
SECTION 1
DISASSEMBLY
1-1.
REAR COVER REMOVAL
1-2.
SPEAKER REMOVAL
1-5.
TERMINAL BRACKET AND J1 BOARD
REMOVAL
1-6.
F AND BC BOARDS  REMOVAL
1-3.
CHASSIS ASSY REMOVAL
1-4.
SERVICE POSITION
– 7 –
KV-AR292M50/AR292M81
RM-W102
1 Four screws
     (+BVTAP 3 × 12)
4 Two screws (Washer head)
     (+BVTP 3 × 12)
3 Four Hooks
2 A Board
2 Five Hooks     
5 Three Hooks     
3 Cover, H
4 H2 Board
H1 Board
    
1-9.
H1 AND H2 BOARDS REMOVAL
1-10. A BOARD REMOVAL
1-7.
D3 BOARD REMOVAL
2 D3 Board
1 Three Hooks
1-8.
B BOARD REMOVAL
1 Five Hooks
2 B
 Board
    
– 8 –
KV-AR292M50/AR292M81
RM-W102
• REMOVAL OF ANODE-CAP
Note:
• After removing the anode, short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT
shield or carbon paint on the CRT.
REMOVING PROCEDURES
Turn up one side of the rubber cap in the direction
indicated by the arrow a.
Using a thumb pull up the rubber cap firmly in the direc-
tion indicated by the arrow b.
When one side of the rubber cap is separated from the
anode button,  the anode-cap can be removed by
turning up the rubber cap and pulling it up in the
direction of the arrow 
c.
HOW TO HANDLE AN ANODE-CAP
Do not damage the surface of anode-caps with
sharp shaped objects.
Do not press the rubber too hard so as not to
damage the inside of anode-cap.
A metal fitting called the shatter-hook terminal is
built into the rubber.
Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage
the rubber.
a
a
b
b
c
anode button
1-11. PICTURE TUBE  REMOVAL
Note:
Please make sure the TV set is not in standing position before removing necessary CRT support located on bottom
right and left.
1) Place the TV set with the CRT face down on a cushion jig.
2) Remove the rear cover.
3) Unplug all inter connecting leads from the Deflection Yoke, Neck assy, Degaussing Coil.
6
 Earth Coating Assy
4 Anode Cap Removal
5 Band, DGC Removal
8 C Board Removal
9 Chassis Assy Removal
0
 VM Board Removal
qd
 Holder, DGC(2) Removal
qs
 Spring Tension(2) Removal
qg
 Screw Tapping 7+
 
Crown Washer
qf
 Degaussing Coil
7 Loosen the Neck Assembly
  fixing screw and removal
qa
 Loosen the Deflection Yoke
  fixing screw and remove
Page of 127