– 10 –
KV-AR25M81A
RM-952
• The following adjustments should be made when a complete
realignment is required or a new picture tube is installed.
• These adjustments should be performed with rated power
supply voltage unless otherwise noted.
Controls and switches should be set as follows unless otherwise noted:
PICTURE control ...........................................................  normal
BRIGHTNESS control ...................................................  normal
Perform the adjustments in the following order :
1. Beam Landing
2. Convergence
3. Focus
4. White Balance
Note :  Test Equipment Required.
1. Pattern Generator
2. Degausser
3. Oscilloscope
SECTION 2
SET-UP ADJUSTMENTS
normal
Preparation :
• In order to reduce the influence of geomagnetism on the set's
picture tube, face it east or west.
• Switch on the set's power and degauss with the degausser.
2-1. BEAM LANDING
1. Input a white signal with the pattern generator.
Contrast
Brightness
2. Position neck assy as shown in Fig2-2.
3. Set the pattern generator raster signal to a green raster.
4. Move the deflection yoke to the rear and adjust with the
purity control so that the green is at the center and the blue
and the red take up equally sized areas on each side.
(See Figures 2-1 through 2-4.)
5. Move the deflection yoke forward and adjust so that the
entire screen is green. (See Figure 2-2.)
6. Switch the raster signal to blue, then to red and verify the
condition.
7. When the position of the deflection yoke has been decided,
fasten the deflection yoke with the screws and DY spacers.
8. If the beam does not land correctly in all the corners, use a
magnet to adjust it.
(See Figure 2-5.)
}
Fig. 2-1
Fig. 2-2
Fig. 2-5
Fig. 2-4
Fig. 2-3
Neck assy
G2
G1
G3
Align the edge of
the neck assy with
the edge of the G2 grid.
a
b
b
c
c
d
d
a
Purity control
corrects this area.
Disk magnets or rotatable
disk magnets correct these
areas (a-d).
Deflection yoke positioning
corrects these areas.
Red
Blue
Green
Purity control
– 11 –
KV-AR25M81A
RM-952
2-2. CONVERGENCE
Preparation :
• Before starting this adjustment, adjust the focus, horizontal size
and vertical size.
• Receive dot/hatch signal.
• Pic mode: Personal (Pic 90%, Brightness 50%, Colour 50 %,
Hue 50%, Sharpness 50%).
(1)
Horizontal and Vertical Static Convergence
1. (Moving horizontally), adjust the H.STAT control so that the
red, green and blue dots are on top of each other at the center of
the screen.
2. (Moving vertically), adjust the V.STAT magnet so that the red,
green and blue dots are on top of each other at the center of the
screen.
3. If the H.STAT variable resistor cannot bring the red, green and
blue dots together at the center of the screen, adjust the
horizontal convergence with the H.STAT variable resistor and
the V.STAT magnet in the manner given below.
(In this case, the H.STAT variable resistor and the V.STAT
magnet influence each other, so be sure to perform adjustments
while tracking.)
1
V. STAT
2
H. STAT VR
3
H. STAT VR
V. STST
Magnet
RV702
H. STAT
RV701
SCREEN (G2)
C6 Board
Center dot
R
G
B
R
G
B
Purity
BMC
BMC (Hexapole)
Purity
DY pocket
V.STAT
V.STAT
R
R
G
G
B
B
a
a
b
b
b
R
R
G
G
B
B
a
b
R
R
G
G
B
B
a
a
b
b
b
– 12 –
KV-AR25M81A
RM-952
5
Y separation axis correction magnet adjustment.
1. Receive the cross-hatch signal and adjust [PICTURE] to [MIN]
and [BRIGHTNESS] to [STANDARD]  .
2. Adjust the Y separation axis correction magnet on the neck
assembly so that the horizontal lines at the top and bottom of
the screen are straight.
Note
1. The Red and Blue magnets should be equally far from the
horizontal center line.
2. Do not separate the Red and Blue magnets too far.
(Less than   8 mm)
(2) Dynamic Convergence Adjustment
Preparation:
• Before starting this adjustment, adjust the horizontal static
convergence and the vertical static convergence
4
BMC (Hexapole) Magnet.
If the red, green and blue dots are not balanced or aligned, then
use the BMC magnet to adjust in the manner described below.
R G
B
R
G
B
R
G B
R
B
R
G
G
G
B
R
B
Neck assy
Neck assy
Blue
Red
Blue
Red
VM1 board
VM1 board
R B
R B
TLH
TLV
YCH
XCV
B
R
R
B
– 13 –
KV-AR25M81A
RM-952
(3) Screen-corner Convergence
Fix a Permalloy assy corresponding to the misconverged
areas.
2-3. FOCUS ADJUSTMENT
FOCUS adjustment should be completed before W/B adjustment.
1.
Receive digital monoscope pattern.
2.
Set "Picture Mode" to "DYNAMIC".
3.
Adjust focus VR so that the lion teeth becomes just focus.
4.
Change the receiving signal to white pattern blue back.
5.
Confirm Magenta ring is not noticable. Incase magneta ring is
obvious, adjust FOCUS VR to take balance of MAGENTA
RING and FOCUS.
TLV
Rotate
TLV-2 VOL (29”, 34”) on DY
Rotate
TLV
VOL (25”)
XCV
Rotate
XCV
Adj core on DY
YCH
Rotate
YCH
VOL on DY
TLH
Insert
TLH
Correction Plate to DY Pocket
(Left or Right)
ON DY:
FLYBACK TRANSFORMER  (T503)
YCH
XCV
TLV1
TLV2
b
a
c
d
a-d : screen-corner
        misconvergence
a
b
c
d
Permalloy assembly