– 9 –
KV-AR25M81A
RM-952
• REMOVAL OF ANODE-CAP
Note:
• After removing the anode, short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT
shield or carbon paint on the CRT.
• REMOVING PROCEDURES
Turn up one side of the rubber cap in the direction
indicated by the arrow 
a.
Using a thumb pull up the rubber cap firmly in the direc-
tion indicated by the arrow 
b.
When one side of the rubber cap is separated from the
anode button,  the anode-cap can be removed by
turning up the rubber cap and pulling it up in the
direction of the arrow 
c.
• HOW TO HANDLE AN ANODE-CAP
Do not damage the surface of anode-caps with
sharp shaped objects.
Do not press the rubber too hard so as not to
damage the inside of anode-cap.
A metal fitting called the shatter-hook terminal is
built into the rubber.
Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage
the rubber.
a
a
b
b
c
anode button
– 10 –
KV-AR25M81A
RM-952
• The following adjustments should be made when a complete
realignment is required or a new picture tube is installed.
• These adjustments should be performed with rated power
supply voltage unless otherwise noted.
Controls and switches should be set as follows unless otherwise noted:
PICTURE control ...........................................................  normal
BRIGHTNESS control ...................................................  normal
Perform the adjustments in the following order :
1. Beam Landing
2. Convergence
3. Focus
4. White Balance
Note :  Test Equipment Required.
1. Pattern Generator
2. Degausser
3. Oscilloscope
SECTION 2
SET-UP ADJUSTMENTS
normal
Preparation :
• In order to reduce the influence of geomagnetism on the set's
picture tube, face it east or west.
• Switch on the set's power and degauss with the degausser.
2-1. BEAM LANDING
1. Input a white signal with the pattern generator.
Contrast
Brightness
2. Position neck assy as shown in Fig2-2.
3. Set the pattern generator raster signal to a green raster.
4. Move the deflection yoke to the rear and adjust with the
purity control so that the green is at the center and the blue
and the red take up equally sized areas on each side.
(See Figures 2-1 through 2-4.)
5. Move the deflection yoke forward and adjust so that the
entire screen is green. (See Figure 2-2.)
6. Switch the raster signal to blue, then to red and verify the
condition.
7. When the position of the deflection yoke has been decided,
fasten the deflection yoke with the screws and DY spacers.
8. If the beam does not land correctly in all the corners, use a
magnet to adjust it.
(See Figure 2-5.)
}
Fig. 2-1
Fig. 2-2
Fig. 2-5
Fig. 2-4
Fig. 2-3
Neck assy
G2
G1
G3
Align the edge of
the neck assy with
the edge of the G2 grid.
a
b
b
c
c
d
d
a
Purity control
corrects this area.
Disk magnets or rotatable
disk magnets correct these
areas (a-d).
Deflection yoke positioning
corrects these areas.
Red
Blue
Green
Purity control
– 11 –
KV-AR25M81A
RM-952
2-2. CONVERGENCE
Preparation :
• Before starting this adjustment, adjust the focus, horizontal size
and vertical size.
• Receive dot/hatch signal.
• Pic mode: Personal (Pic 90%, Brightness 50%, Colour 50 %,
Hue 50%, Sharpness 50%).
(1)
Horizontal and Vertical Static Convergence
1. (Moving horizontally), adjust the H.STAT control so that the
red, green and blue dots are on top of each other at the center of
the screen.
2. (Moving vertically), adjust the V.STAT magnet so that the red,
green and blue dots are on top of each other at the center of the
screen.
3. If the H.STAT variable resistor cannot bring the red, green and
blue dots together at the center of the screen, adjust the
horizontal convergence with the H.STAT variable resistor and
the V.STAT magnet in the manner given below.
(In this case, the H.STAT variable resistor and the V.STAT
magnet influence each other, so be sure to perform adjustments
while tracking.)
1
V. STAT
2
H. STAT VR
3
H. STAT VR
V. STST
Magnet
RV702
H. STAT
RV701
SCREEN (G2)
C6 Board
Center dot
R
G
B
R
G
B
Purity
BMC
BMC (Hexapole)
Purity
DY pocket
V.STAT
V.STAT
R
R
G
G
B
B
a
a
b
b
b
R
R
G
G
B
B
a
b
R
R
G
G
B
B
a
a
b
b
b
– 12 –
KV-AR25M81A
RM-952
5
Y separation axis correction magnet adjustment.
1. Receive the cross-hatch signal and adjust [PICTURE] to [MIN]
and [BRIGHTNESS] to [STANDARD]  .
2. Adjust the Y separation axis correction magnet on the neck
assembly so that the horizontal lines at the top and bottom of
the screen are straight.
Note
1. The Red and Blue magnets should be equally far from the
horizontal center line.
2. Do not separate the Red and Blue magnets too far.
(Less than   8 mm)
(2) Dynamic Convergence Adjustment
Preparation:
• Before starting this adjustment, adjust the horizontal static
convergence and the vertical static convergence
4
BMC (Hexapole) Magnet.
If the red, green and blue dots are not balanced or aligned, then
use the BMC magnet to adjust in the manner described below.
R G
B
R
G
B
R
G B
R
B
R
G
G
G
B
R
B
Neck assy
Neck assy
Blue
Red
Blue
Red
VM1 board
VM1 board
R B
R B
TLH
TLV
YCH
XCV
B
R
R
B
Page of 89
Display

Click on the first or last page to see other KV-AR25M81A service manuals if exist.