— 26 —
KV-34FV310/38FV310
DISPLAY POSITION ADJUSTMENT (DISP)
1.  Input a color-bar signal.
2.  Set to Service Adjustment Mode.
3.  Select DISP with  1  and  4  .
4.  Adjust values of DISP with  3  and  6  to adjust characters to the center.
5.  Write to memory by pressing  MUTING  then  ENTER  .
6.  Check to see if the text is displayed on the screen.
service   micro     disp   48
ntsc
vchp
Category
Display 
Item
Mode
Item 
Data
Signal
Type
00000000 00000000
SUB BRIGHT ADJUSTMENT (SBRT)
1.  Input a monoscope signal.
2.  Activate the Service Adjustment Mode.
3.  Set the PICTURE and BRIGHTNESS to minimum.
4.  Select the SBRT item with  1  and  4  .
5. Adjust the values of SBRT with  3  and  6  to obtain a faintly visible 
crosshatch.
6. Press MUTING  then  ENTER  to save into the memory.
SUB HUE, SUB COLOR ADJUSTMENT 
(SHUE, SCOL)
 
[RF], [VIDEO] [VIDEO MODE PRO]
1.  Input color-bar signal at 75%.
2.  Set screen to Pro Mode.
3.  Activate the Service Adjustment Mode.
4.  Set (PIC) to 100% and (COL) to 50%. 
5.  Connect an oscilloscope probe to C Board, CN705 Pin  4  Blue Out. 
6.  Select the SHUE and SCOL item with  1  and  4  .
7.  While showing the SHUE item, adjust the waveform with  1  and  4  until 
the second and third bars show the same level 
(V2 = V3 + 0.2Vpp).  
8.  While showing the SCOL item, adjust the waveform with  3  and  6  until 
the fi rst and fourth bars show the same level 
(V1 = V4 + 0.2Vpp). 
9. For Trinorma models inspect each system NTSC, PAL M & N. 
 
V1 V2 V3 V4
10. Press  MUTING  then  ENTER  to save into the memory.
4-6. A BOARD ADJUSTMENTS
H. FREQUENCY (FREE RUN) CHECK
1.  Input a TV mode (RF) with no signal.
2.  Connect a frequency counter to base of Q501 
(TP-25 H. DRIVE) on the A Board.
3.  Check H. Frequency for 15734 ± 400/-200 Hz.
V. FREQUENCY (FREE RUN) CHECK
1.  Select video 1 with no signal input.
2.  Set the conditions for a standard setting.
3.  Connect the frequency counter to TP-27 (V OUT) or CN501 pin  6
(V DY+) and ground on the A Board .
4.  Check that V. Frequency shows 60 ± 4 Hz.
SUBCONTRAST ADJUSTMENT (RDRV)
1.  Input a color-bar signal and set the level to 75%.
2.  Set in Pro mode.
3.  Activate the Service Adjustment Mode. 
4.  Set GON and BON items. Using  3  and  6  set each to the following 
values. Leave RON set to “1”.
service     video     rdrv
ntsc
vchp
Category
Display 
Item
Mode
Item 
Data
Signal
Type
00000000 00000000
26
 
 R ON:   ON 
(1)
 
G ON:   OFF 
(0)
 
B ON:   OFF 
(0)
5.  Select SCON with  1  and  4  .
6.  Connect an oscilloscope probe to C Board, CN705 Pin 3  Blue Out.
7.  Adjust the value of SCON with  3  and  6  for
 
1.90 ± 0.01Vpp.
8.  Reset GON and BON values to “1”.
 
 R ON:   ON 
(1)
 
G ON:   ON 
(1)
 
B ON:   ON 
(1)
9. Press MUTING  then  ENTER  to save into the memory.
10. After adjusting SCON, if still out of xpec, use RDRV resistor as a 
fi ne adjustment.
— 27 —
KV-34FV310/38FV310
[YUV] [VIDEO MODE PRO]
1.  Input color-bar signal at 75%.
2.  Set screen to Pro Mode.
3.  Activate the Service Adjustment Mode.
4.  Set (PIC) to 100% and (COL) to 50%. 
5.  Connect an oscilloscope probe to C Board, CN705 Pin  4  Blue Out. 
6.  Select the SHUE and SCOL item with  1  and  4  .
7.  While showing the SHUE item, adjust the waveform with  1  and  4  
until the second and third bars show the same level 
(V2 = V3 + 0.2Vpp).  
8.  While showing the SCOL item, adjust the waveform with  3  and  6  
until the fi rst and fourth bars show the same level 
(V1 = V4 + 0.2Vpp).  
V1 V2 V3 V4
9. Press MUTING  then  ENTER  to save into the memory.
[YUV] [VIDEO MODE VIVID]
1.  Input color-bar signal at 75%.
2.  Set screen to Vivid Mode.
3.  Activate the Service Adjustment Mode.
4.  Set (PIC) to 100% and (COL) to 50%. 
5.  Connect an oscilloscope probe to C Board, CN705 Pin  4  Blue Out. 
6.  Select the SHUE and SCOL item with  1  and  4  .
7.  While showing the SHUE item, adjust the waveform with  1  and  4  
until the second and third bars show the same level 
(V2 = V3 + 0.2Vpp).  
8.  While showing the SCOL item, adjust the waveform with  3  and  6  
until the fi rst and fourth bars show the same level 
(V1 = V4 + 0.2Vpp).
V1 V2 V3 V4
9. Press MUTING  then  ENTER  to save into the memory.
V. SIZE ADJUSTMENT (VSIZ)
1.  Input a crosshatch signal.
2.  Activate the Service Adjustment Mode.
3.  Select the VSIZ item with  1  and  4  .
4. Adjust value of VPOS with  1  and  4  for the best vertical center.
5. Press MUTING  then  ENTER  to save into the memory.
 
V. CENTER ADJUSTMENT (VPOS)
Perform this adjustment after performing H. Frequency 
(Free Run) Check.
1.  Input a crosshatch signal.
2.  Activate the Service Adjustment Mode.
3.  Select the VPOS item with  1  and  4  .
4.  Adjust value of VPOS with  3  and  6  for the best vertical center.
5. Press MUTING  then  ENTER  to save into the memory.
H. CENTER ADJUSTMENT (HPOS)
Perform this adjustment after performing H. Frequency 
(Free Run) Check.
1.  Input a crosshatch signal.
2.  Activate the Service Adjustment Mode.
3.  Select the HPOS item with  1  and  4  .
4.  Adjust the value of HPOS with  3  and  6  for the best horizontal center.
5. Press MUTING  then  ENTER  to save into the memory.
H. SIZE ADJUSTMENT (HSIZ)
1.  Input a monoscope signal.
2.  Activate the Service Adjustment Mode.
3.  Select HSIZ with  1  and  4  .
4. Adjust with 3  and  6  for the best horizontal size.
5. Press MUTING  then  ENTER  to save into the memory.
— 28 —
KV-34FV310/38FV310
V. LINEARITY (VLIN), V. CORRECTION 
(SCOR), PIN AMP (PAMP), AND 
HORIZONTAL TRAPEZOID (HTRP) 
ADJUSTMENTS
1.  Input a crosshatch signal.
2.  Activate the Service Adjustment Mode.
3.  Select VLIN, SCOR, PAMP, and HTRP with  1  and  4 .
4. Adjust with 3  and  6  for the best horizontal size.
5.  Press  MUTING  then  ENTER  to save into the memory.
V LINEARITY (VLIN)
V CORRECTION (SCOR)
PIN AMP (PAMP)
HORIZONTAL TRAPEZOID (HTRP)
V. ANGLE (VANG), V. BOW (VBOW), UPPER 
PIN (UPIN) AND LOW PIN (LPIN) 
ADJUSTMENTS
1.  Input a crosshatch signal.
2.  Activate the Service Adjustment Mode.
3.  Select VANG, VBOW, UPIN, and LPIN with  1  and  4 .
4. Adjust with 3  and  6  for the best picture.
5. Press MUTING  then  ENTER  to save into the memory.
V ANGLE (VANG)
V BOW (VBOW)
UPPER PIN (UPIN)
LOW PIN (LPIN)
SERVICE ADJUSTMENT MODE MEMORY
1.  After completing all adjustments, press  0  then  ENTER  .
Read From Memory
Green
Red
ENTER
0
service     defl     vbow    
ntsc
vchp
Category
Display 
Item
Mode
Item 
Data
Signal
Type
00000000 00000000
7
— 29 —
KV-34FV310/38FV310
5-1.  CIRCUIT BOARDS LOCATION
5-2.  PRINTED WIRING BOARD AND 
SCHEMATIC DIAGRAM INFORMATION
All capacitors are in µF unless otherwise noted. pF : µµF 50V or less are 
not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise specifi ed.
All resistors are in ohms.  kΩ=1000Ω, MΩ=1000kΩ
Indication of resistance, which does not have one for rating electrical 
power, is as follows: 
Pitch : 5mm 
 
 
 
   Rating 
electrical 
power 
1
/
 4 
W
1
/
 4 
W in resistance, 
1
/
10 
W and 
1
/
 8 
W in chip resistance.
: nonfl ammable resistor
 : fusible resistor
 : internal component
 : panel designation and adjustment for repair
 : earth ground
 : earth-chassis
All variable and adjustable resistors have characteristic curve B, unless 
otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10MΩ digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production tolerances.
All voltages are in V.
S : Measurement impossibility.
: B+line
: B-line (Actual measured value may be different).
: signal path (RF)
Circled numbers are waveform references.
REFERENCE INFORMATION
RESISTOR                      
: RN        METAL FILM
: RC        SOLID
: FPRD   NONFLAMMABLE CARBON
: FUSE   NONFLAMMABLE FUSIBLE
: RW       NONFLAMMABLE WIREWOUND
: RS        NONFLAMMABLE METAL OXIDE
: RB        NONFLAMMABLE CEMENT
       ADJUSTMENT RESISTOR
COIL      
: LF-8L   MICRO INDUCTOR
The components identifi ed by shading and 
!
 symbol are critical for safety. Replace 
only with part number specifi ed. 
The symbol 
 indicates a fast operating fuse and is displayed on the component 
side of the board. Replace only with fuse of the same rating as marked.
The components identifi ed by X in this basic schematic diagram have 
been carefully factory-selected for each set in order to satisfy regulations 
regarding X-ray radiation. Should replacement be necessary, replace 
only with the value originally used.
When replacing components identifi ed by Y, make the necessary 
adjustments as indicated.  If the results do not meet the specifi ed value, 
change the component identifi ed by X and repeat the adjustment until 
the specifi ed value is achieved. (Refer to Section 3: Safety Related 
Adjustments on Page 16.)
When replacing the parts listed in the table below, it is important to 
perform the related adjustments.
D BOARD: 
HV HOLD DOWN
D8022, IC8001, IC8004, IC8005,
RV8002
IC8104, R8014, R8015, R8016,
R8017, R8019, R8021, R8046,
R8052, R8072, R8078, R8079,
R8082, R8091, R8095
GW BOARD: 
IC601
Part Replaced (Y)
Adjustment (X)
CAPACITOR
: TA        TANTALUM
: PS        STYROL
: PP        POLYPROPYLENE
: PT        MYLAR
: MPS     METALIZED POLYESTER
: MPP     METALIZED POLYPROPYLENE
: ALB      BIPOLAR
: ALT      HIGH TEMPERATURE
: ALR      HIGH RIPPLE
SECTION 5:  DIAGRAMS
D Board
A Board
GW Board
V Board
C Board
Page of 125