KV-29FS140 
10
1-1.  REAR COVER REMOVAL
SECTION 1:  DISASSEMBLY
1-2. CHASSIS ASSEMBLY REMOVAL
1  12 screws +BVTP2 4X16
2  Rear cover
1
KV-29FS140
KV-29FS140 
11
1-3. SERVICE POSITION
1  Release AC Power Cord
2  Release wires from 
  3 wire holders
2  Rotate A Board and
 H2 Board
CV Board
 A Board 
H2 Board
KV-29FS140
KV-29FS140 
12
1.  Discharge the anode of the CRT and remove 
the anode cap.
2.  Unplug all interconnecting leads from the 
defl ection yoke, neck assembly, degaussing 
coils and CRT grounding strap.
3.  Remove the CV Board from the CRT.
4.   Remove the chassis assembly.
5.  Loosen the neck assembly fi xing screw and 
remove.
6.  Loosen the defl ection yoke fi xing screw and 
remove.
7.  Place the set with the CRT face down on 
a cushion and remove the degaussing coil 
holders.
8.  Remove the degaussing coils.
9.  Remove the CRT grounding strap and spring 
tension devices.
10. Unscrew the four CRT fi xing screws [located on 
each CRT corner] and remove the CRT  [Take 
care not to handle the CRT by the neck].
1-4.  PICTURE TUBE REMOVAL
WARNING: BEFORE REMOVING THE ANODE CAP
High voltage remains in the CRT even after the power is disconnected. To avoid electric shock, 
discharge CRT before attempting to remove the anode cap. Short between anode and CRT 
coated earth ground strap.
 
ANODE CAP REMOVAL PROCEDURE
WARNING: High voltage remains in the CRT even after the power is disconnected. To avoid electric shock, discharge CRT before attempting to  remove 
the anode cap.  Short between anode and coated earth ground strap of CRT. 
NOTE:  After removing the anode cap, short circuit the anode of the picture tube and the anode cap to either the metal chassis, CRT shield, or carbon 
painted on the CRT. 
REMOVAL PROCEDURES
HOW TO HANDLE AN ANODE CAP
1.  Do not use sharp objects which may cause damage to the surface of the 
anode cap. 
2.  To avoid damaging the anode cap, do not squeeze the rubber covering too 
hard. A material fi tting called a shatter-hook terminal is built into the rubber. 
3.  Do not force turn the foot of the rubber cover. This may cause the shatter-
hook terminal to protrude and damage the rubber.
Turn up one side of the rubber cap in 
the direction indicated by arrow  a  .
Use your thumb to pull the rubber
cap fi rmly in the direction indicated
by arrow  b  .
When one side of the rubber cap separates from 
the anode button, the anode cap can be removed 
by turning the rubber cap and pulling it in the 
direction of arrow  c  .
a
b
Anode Button
c
4
1
10
9
8
7
2
3
5
6
KV-29FS140
KV-29FS140 
13
The following adjustments should be made when a complete realignment 
is required or a new picture tube is installed. 
These adjustments should be performed with rated power supply voltage 
unless otherwise noted.
Set the controls as follows unless otherwise noted:
Picture control 
NORMAL
Brightness control  NORMAL
SECTION 2:  SET-UP ADJUSTMENTS
Perform the adjustments in order as follows:
 1. 
Beam 
Landing
 2. 
Convergence
 3. 
Focus
 4. 
Screen 
(G2)
 5. 
White 
Balance
Note Test Equipment Required:
 
1. 
Color Bar Pattern Generator
 2. 
Degausser
 
3. 
DC Power Supply
 4. 
Digital 
Multimeter
2-1. BEAM LANDING
Before beginning adjustment procedure:
1.  Feed in the white pattern signal.
2.  In order to reduce the geomagnetism on the set’s picture tube, face 
it east or west.
Adjustment Procedure
1.  Input a raster signal with the pattern generator.
2.  Loosen the defl ection yoke (DY) mounting screw, and set the purity 
control to the center as shown below:
Purity control
3.  Position the VM coil as shown below:
VM coil
G2
G1
G3
Align the edge of
the VM coil with
the edge of the G3 grid.
G4
4.  Set the raster signal of the pattern generator to green.
5.  Move the defl ection yoke backward, and adjust with the purity 
control so that green is in the center and red and blue are even on 
both sides. 
Red
Blue
Green
6.  Move the defl ection yoke forward, and adjust so that the entire 
screen becomes green. 
7.  Switch over the raster signal to red, then blue and confi rm the 
condition.
8.  When the position of the defl ection yoke is determined, tighten it 
with the defl ection yoke mounting screw.
9.  If landing at the corner is not right, adjust by using the disk 
magnets. 
a
b
b
c
c
d
d
a
Purity control
corrects this area.
Disc magnets or rotatable
disc magnets correct these
areas (a-d).
Deflection yoke positioning
corrects these areas.
 5. 
Oscilloscope
 6. 
Landing 
Checker
 7. 
XCV 
Adjuster
Page of 57