DOWNLOAD Sony KV-29FS12A Service Manual ↓ Size: 14.46 MB | Pages: 55 in PDF or view online for FREE

Model
KV-29FS12A
Pages
55
Size
14.46 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
kv-29fs12a.pdf
Date

Sony KV-29FS12A Service Manual ▷ View online

— 17 —
KV-29FS12A
3-2. CONVERGENCE
Before starting convergence adjustments:
1. Perform FOCUS, V.LIN AND V.SIZE adjustments.
2. Set BRIGHTNESS control to minimum.
3. Feed in dot pattern.
Vertical Static Convergence
1. Adjust V.STAT magnet to converge red, green and blue
dots in the center of the screen (Vertical movement adjust
V.STAT RV701 to converge).
B
G
R
Center dot
R G B
V.STAT magnet
RV701
V.STAT
2. Tilt the V.STAT magnet and adjust static convergence to open
or close the V.STAT magnet.
 
When the V.STAT magnet is moved in the direction of arrows
a and b, red, green, and blue dots move as shown below:
a
b
b
B
G
R
a
b
B
G
R
a
B
G
R
R
G
B
b
R
G
B
b
b
a
R
G
B
(1)
(3)
(2)
Dynamic Convergence Adjustment
Before performing this adjustment, perform Horizontal
and Vertical Static Convergence Adjustment.
1. Slightly loosen deflection yoke screw.
2. Remove deflection yoke spacers.
3. Move the deflection yoke for best convergence
as shown on the following page.
Horizontal Static Convergence
If the blue dot does not converge with the red and green dots,
perform the following:
1. Move BMC magnet (a) to correct insufficient H. Static
convergence.
2. Rotate BMC magnet (b) to correct insufficient V. Static
convergence.
3. After adjusting the BMC magnet, repeat Beam Landing
Adjustment.
BMC MAGNET
PURITY
V.STAT
b
BMC magnet
— 18 —
KV-29FS12A
R G B B G R
R G B
R
R
R
G
B
G
B
G
B
R G B
B G R
R
G
B
R
G
B
B G R R G B
4. Tighten the deflection yoke screw.
5. Install the deflection yoke spacers.
TLH Plate Adjustment
1. Input crosshatch pattern.
2. Adjust PICTURE QUALITY to standard, PICTURE and
BRIGHTNESS to 50%, and OTHER to standard.
3. Adjust the Horizontal Convergence of red and blue dots
by tilting the TLH plate on the deflection yoke.
(TLV)
YCH
XCV
TLV
CA
Board
VA
Board
RV701
 V.STAT
TLH Plate
  B R              R B
(R)(B)          (B)(R)
TLH+
TLH-
3-3. FOCUS
1. Adjust FOCUS control for best picture.
b
a
c
d
a
b
d
a-d: screen-corner
misconvergence
c
4. Adjust XCV core to balance X axis.
5. Adjust YCH VR to balance Y axis.
6. Adjust vertical red and blue convergence with V.TILT
(TLV VR).
Note: Perform adjustments 3-6 while tracking items 1 and 2.
Screen-Corner Convergence
1. Affix a permalloy assembly corresponding to the
misconverged areas.
Focus (FV)
Screen (G2)
— 19 —
KV-29FS12A
3-5. METHOD OF SETTING THE SERVICE
ADJUSTMENT MODE
Service Mode Procedure
1. Standby mode (power off).
2.  Press 
Display
Channel 5
Sound volume
Power
+
on the Remote Commander (press each button within a
second).
Service Adjustment Mode In
1. The CRT displays the item being adjusted.
2. Press 
 or 
 on the Remote Commander to select the item.
3. Press 
 or 
 on the Remote Commander to change the
data.
4. Press 
 then 
 to save into the memory.
Service Adjustment Mode Memory
Turn set off then on to exit Service Adjustment Mode.
service     defl     hsiz
16
ntsc
vchp     00000000    00000000
Category
Display 
Item
Mode
Item 
Data
Signal
Type
write
3-4. SCREEN (G2)
1. Input a dots pattern.
2. Set the PICTURE and BRIGHTNESS controls at minimum
and COLOR control at normal.
3. Adjust SBRT, GCUT, BCUT in service mode with an
oscilloscope as shown below so that voltages on the red,
green, and blue cathodes are 170 VDC ± 2V.
 
Pedestal
170 VDC – 2V
Ground
4. Observe the screen and adjust SCREEN (G2) VR in FBT
to obtain the faintly visible background of dot signal.
3-6. WHITE BALANCE ADJUSTMENTS
1. Input an entire white signal with burst.
2. Set to Service Adjustment Mode.
3. Set the PICTURE and BRIGHTNESS to minimum.
4. Adjust with SBRT if necessary.
5. Select GCUT and BCUT with 
 and 
 .
6. Adjust with 
 and 
 for the best white balance.
7. Set PICTURE and BRIGHTNESS to maximum.
8. Select GDRV and BDRV with 
 and 
 .
9. Adjust with 
 and 
 for the best white balance.
10. To write into memory, press 
 then 
 .
— 20 —
KV-29FS12A
SECTION 4
SAFETY RELATED ADJUSTMENTS
4-1.
 R564 CONFIRMATION METHOD
(HV HOLD-DOWN  CONFIRMATION)  AND
READJUSTMENTS
The following adjustments should always be performed when
replacing the following components which are marked with   on
the schematic diagram:
Preparation Before Confirmation
1. Using a Variac, apply AC input voltage: 120 ± 2 VAC.
2. Turn the POWER switch ON.
3. Input a white signal and set the PICTURE and
BRIGHTNESS controls to maximum.
4. Confirm that the voltage between C546 (+) or TP503
and ground is more than 21.0 VDC.
Hold-Down Operation Confirmation
1. Connect the current meter between Pin 11 of the FBT
(T505) and the PWB land where Pin 11 would normally
attach. (See Figure 1 on the next page.)
2. Input a dot signal and set PICTURE and BRIGHTNESS
to minimum: IABL = 1730 ± 100 
µ
A.
3. Confirm the voltage of A Board TP-600 is 135 ± 1.5 VDC.
4. Connect the digital voltmeter and the DC power supply
via diode 1SS119 to C546 (+) and ground. (See Figure 1
on the next page.)
5. Increase the DC power voltage gradually until the picture
blanks out.
6. Turn DC power source off immediately.
7. Read the digital voltmeter indication
(standard < 24.78+0,-0.1  VDC).
8. Input a white signal and set PICTURE and BRIGHTNESS to
maximum: IABL = 1730 ± 100 
µ
A.
9. Repeat Steps 4 to 7.
Hold-Down Readjustment
If the setting indicated in  Step 2 of Hold-Down Operation
Confirmation cannot be met, readjustment should be performed by
altering the resistance value of R564 component marked with   .
+
IABL
ABL
T505
FBT
range
-
ammeter
3.0 mA DC
A
4-2. B+ VOLTAGE CONFIRMATION AND
ADJUSTMENT
Note: The following adjustments should always be performed
when replacing the following components, which are marked
with   on the schematic diagram on the A Board.
A BOARD:
IC601, PH601
1. Using a Variac, apply AC input voltage: 130 + 2.0, -0.0 VAC.
2. Input a dot signal.
3. Set the PICTURE and BRIGHTNESS controls to minimum.
4. Confirm that the voltage of A Board TP-600 is <136.5  VDC.
5. If Step 3 is not satisfied, replace the components listed above,
then repeat Steps 1–3.
Part Replaced ( )
Adjustment ( )
DY, T505, CRT, IC501, C507,
C520, C505, C509, C515, T504,
T503, C551, L510, C546, C537,
C547, D517, D518, D519, R560,
R561, R562, R563, R565, R566,
R567, R525 ....................... A Board
IC301 .............................. MA Board
HV HOLD-DOWN
R564
Page of 55
Display

Click on the first or last page to see other KV-29FS12A service manuals if exist.