— 14 —
KV-29FS100/29FV300/34FS100/
34FV250/38FV250
2-2-4.  DYNAMIC CONVERGENCE  
ADJUSTMENT
Before starting, perform Vertical and Horizontal Static Convergence 
Adjustment.
1.  Slightly loosen deflection yoke screw.
2.  Remove deflection yoke spacers.
3.  Move the deflection yoke for best convergence as  
 
shown below:
R G B
B G R
R
G
B
R
G
B
B G R R G B
R G B
R
R
R
G
B
G
B
G
B
R G B B G R
4.  Tighten the deflection yoke screw.
5.  Install the deflection yoke spacers.
2-2-5.  SCREEN-CORNER CONVERGENCE
1.  Affix a permalloy assembly corresponding to the misconverged areas: 
b
a
c
d
a
b
a-d: screen-corner
misconvergence
c
d
2-2-6.  TLH PLATE ADJUSTMENT
Preparation:
•  Input crosshatch pattern.
•  Adjust Picture Quality to standard, Picture and Brightness to 50%, and 
Other to standard.
•  Adjust the Horizontal Convergence of red and blue dots by tilting the 
TLH plate on the deflection yoke.
XCV
WA Board
RV701
V.STAT
Y Magnet
TLH Plate
H-TRP
YCH
TLV
C Board
TLH+
TLH-
  B R
(R)(B)
  R B
(B)(R)
1.  Adjust XCV core to balance X axis.
2.  Adjust YCH VR to balance Y axis.
3.  Adjust vertical red and blue convergence with V.TILT (TLV VR.) 
Perform adjustments while tracking items 1 and 2.
4.  Adjust Y MAGNET to correct V.BOW Geometry Distortion.
5.  Adjust H-TRP to correct H.Trapezoid Geometry Distortion.
After adjusting items 4 and 5, confirm overall geometry again.
— 15 —
KV-29FS100/29FV300/34FS100/
34FV250/38FV250
2-3.  FOCUS
1.  Input monoscope signal.
2.  Set user controls to normal.
3.  Set video mode to STANDARD.
4.  Set the PICTURE to maximum.
5.  Adjust at 325 Mark for best center/corner focus balance.
6.  Receive an entire white signal.  Make sure Magenta Ring is at an 
acceptable level.
Focus
Screen (G2)
35
325
35 MARK
325 MARK
CENTER
CIRCLE
2-4.  SCREEN (G2)
1.   Input dot pattern from the pattern generator.
2.   Set the user controls to NORMAL.
3.  Attach the G2-Jig to the C Board.
4.  Adjust RCUT, GCUT, BCUT, and SBRT in service mode with an 
oscilloscope so that voltages on the red, green, and blue cathodes 
are 170 ± 4.0Vdc. 
5.  Observe the screen and adjust SCREEN (G2) VR  to obtain the 
faintly visible background of dot signal.
6.  Push the TEST + JUMP (+ Channel) to cut off the signal.  The screen 
should be bright or dark.  Brightness of raster must be increased 
when adjusting.
7.  Adjust screen VR until the screen is slightly cut off, or scarcely lights 
up.  A signal cannot be seen when the brightness of the raster is high.
8.  Push the JUMP again to release the cut off.
pedestal
GND
170Vdc
 170 + 4.0 Vdc
2-5.  WHITE BALANCE ADJUSTMENTS
����
��� �����
����
��� ������
�������
����
��� �����
��
�������
���� ����� �����
��
�������
����
���� �����
��
�������
���� ��� �������
��
�������
���� ����� �������
��
�������
���� ���� �������
��
���
����
��� ������
87
1.  Set program palette to STANDARD and push RESET.
2.  Input an entire white signal.
3.  Set to Service Adjustment Mode.
4.  Set the PICTURE and BRIGHT to minimum.
5.  Adjust with SBRT if necessary.
6.  Set RCUT to “14”.
7.  Select GCUT and BCUT with  3 and  5 .
8.  Adjust by pressing  1 and  4 for the best white balance.
9.  Set the PICTURE and BRIGHT to maximum.
10. Select GDRV and BDRV with  and  .
11. Adjust with 3 and 6 for the best white balance.
12. Write into the memory by pressing  3 then  5.
13. Repeat steps 1-12 for GDR4, BDR4, GCU4 and BCU4 using      
Video 4 input. 
*  Use values from Sub Contrast Adjustments
White balance should be adjusted after Sub Contrast because 
RDRV is also used in Sub Contrast Adjustment. (See page 22).
— 16 —
KV-29FS100/29FV300/34FS100/
34FV250/38FV250
SECTION 3:  SAFETY RELATED ADJUSTMENTS
3-1.  R530, R531 CONFIRMATION METHOD 
(HOLD-DOWN CONFIRMATION) AND 
READJUSTMENTS
Always perform the following adjustments when replacing the following 
components marked with a Y  mark on the schematic diagram:
� ������
�� ���� ����
����� ����� ����� �����
������ ����� ����� �����
����� ����� ����� �����
����� ����
����� ����
���� �������� � �
���������� � �
3-1-1.  PREPARATION BEFORE 
CONFIRMATION
1.  Using a Variac, apply AC input voltage: 120 +/- 2.0 VAC.
2.  Turn the POWER switch ON.
3.  Input a white signal and set the PICTURE and BRIGHT controls to 
maximum.
4.  Confirm that the voltage of more than 23.0 VDC appears between 
TP85 and ground on the A Board. 
3-1-2.  HOLD-DOWN OPERATION 
CONFIRMATION
1.  Connect the current meter between Pin 11 of the FBT (T503) and the 
PWB land where Pin 11 would normally attach. (See Figure 1).
2.  Input a dot signal and set PICTURE and BRIGHTNESS to minimum: 
IABL = 2175 + 100/ -325 µA.
3.  Confirm the voltage of A Board TP91 is 135 ± 1.5 VDC.
4.  Connect the digital voltmeter and the DC power supply to TP85 and 
ground. (See Figure 1)
5.  Increase the DC power voltage gradually until the picture blanks out.
6.  Turn DC power source off immediately.
7.  Read the digital voltmeter indication (standard = 27.24 + 0.0/ - 0.1 
VDC). 
8.  Input a white signal and set PICTURE and BRIGHTNESS to 
maximum: IABL = 2175 + 100/ -325 µA.
9.  Repeat steps 4 to 7.
3-1-3.  HOLD-DOWN READJUSTMENT
If the setting indicated in Step 2 of Hold-Down Operation Confirmation 
cannot be met, readjustment should be performed by altering the 
resistance value of R530, R531 component marked with X. 
 
3mA DC range
+
-
+
-
A
+
-
FBT
TP85
T503
FBT
TP85
R531 R530
DC Power Supply
digital multimeter
ammeter
 
 
Figure 1
3-2.  B+ VOLTAGE CONFIRMATION AND 
ADJUSTMENTS
Always perform the following adjustments when replacing the following 
components, which are marked with Y on the schematic diagram on the 
GK Board:
     GK BOARD:   IC600, PH602 
1.  Using a Variac, apply AC input voltage: 130 + 2.0/-0.0 VAC
2.  Input a monoscope signal.
3.  Set the PICTURE control and the BRIGHT control to  
 
minimum.
4.  Confirm the voltage on A Board between TP23 and ground is less 
than 136.5 VDC.
5.  If step 4 is not satisfied, replace R530 and R531 on A Board and 
repeat the above steps.    
               
— 17 —
KV-29FS100/29FV300/34FS100/
34FV250/38FV250
4-1.  SETTING SERVICE ADJUSTMENT MODE
1.  Standby mode (Power off).
2.  Press the following buttons on the remote commander within a second 
of each other: 
  DISPLAY  
 Channel  5 
 Sound Volume  + 
 Power
4-1-1.  SERVICE ADJUSTMENT MODE IN
Mode
Disp 
Item 
Item
(Item) 
Order 
Data
VP 
7  SERVICE
HSIZ   
TV
1.  The CRT displays the item being adjusted.
2.  Press   1 or  2 on the Remote Commander to select the item.
3.  Press  3 or   6 on the Remote Commander to change the data.
4.  Press MUTING then ENTER to write into memory.
4-1-2.  SERVICE ADJUSTMENT MODE 
MEMORY
ENTER
MUTING
Disp 
Item 
Item
(Item) 
Order 
Data
VP 
7  SERVICE
HSIZ   
TV
Green
Red
1.  Press  then  on the Remote Commander to initialize.
Disp 
Item 
Item
(Item) 
Order 
Data
VP 
WRITE
HSIZ   
TV
Carry out Step 1 when adjusting 
ID’s 0-7 and when replacing and 
adjusting IC003.
2.   DO NOT turn off set until SERVICE appears.
SECTION 4:  CIRCUIT ADJUSTMENTS
ELECTRICAL ADJUSTMENTS BY REMOTE COMMANDER
Use the Remote Commander (RM-Y180, RM-Y181) to perform the circuit adjustments in this section.
Test Equipment Required:   1. Pattern generator   2. Frequency counter   3. Digital multimeter  4.  Audio oscillator
4-2.  MEMORY WRITE CONFIRMATION 
METHOD
1.  After adjustment, pull out the plug from the AC outlet, then replace 
the plug in the AC outlet again.
2.  Turn the power switch ON and set to Service Mode.
3.  Call the adjusted items again to confirm they were adjusted.
4-3.  REMOTE ADJUSTMENT BUTTONS AND 
INDICATORS
RM-Y181
MUTING
(Enter into 
memory)
POWER
(Service Mode)
2
(Device Item Up)
4
Disp. (Item down)
8
(Initialize)
3
Item 
(Data up)
1
Disp. (Item up)
5
(Device item 
down)
ENTER
(Enter into 
memory)
0
(Remove from 
memory)
VOLUME (+)
(Service Mode)
6
Item 
(Data down)
DISPLAY
(Service Mode)
Page of 85
Display