DOWNLOAD Sony KV-27HS420 (serv.man2) Service Manual ↓ Size: 14.46 MB | Pages: 127 in PDF or view online for FREE

Model
KV-27HS420 (serv.man2)
Pages
127
Size
14.46 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
kv-27hs420-sm2.pdf
Date

Sony KV-27HS420 (serv.man2) Service Manual ▷ View online

26
KV-27HS420/29DRC430/30HS420/32HS420/34HS420
KV-27HS420/29DRC430/30HS420/32HS420/34HS420
SECTION 2:  SET-UP ADJUSTMENTS
Blue
Red
Green
5.  Move the defl ection yoke forward, and adjust so that the entire screen 
becomes green. 
6.  Switch over the raster signal to red and blue and confi rm the 
condition.
7.  When the position of the defl ection yoke is determined, tighten it with 
the defl ection yoke mounting screw.
8.  If landing at the corner is not right, adjust it by using the disk 
magnets. 
a
c
b
d
b
a
c
d
Purity control
corrects this area
Disk magnets
or rotatable disk
magnets correct
these areas (a-d)
Deflection yoke positioning
corrects these areas
2-1. BEAM LANDING
Preparation:
•  Use cross hatch signal to rough adjust focus, G2 and then input a 
white pattern signal.
•  Face the picture tube in an East or West direction to reduce the 
infl uence of geomagnetism.
•  CXA2170-D4 Confi rm Focus data - See 2.4.1 Dynamic Focus/
Dynamic Quadrapole Data Table 1.
•  CXA8070 (Should be set to default) - or unplug CN1 from DY.
 
CXA8070 default (initial) data: (See 4-4. SERVICE DATA for the 
default data values for YBWU, YBWL, RSAP, RUBW, RUMB, RLBW, 
RLMB1, LSAP, LUBW, LUMB, LLBW, LLMB, CADJ, HVCA for each 
model)
•  CXA2170-D1, -D2 table default (initial) data: (See 4-4. SERVICE 
DATA for the default data values for VCEN, VPIN, HTPZ, HCNT, 
PPHA, VANG, VBOW, LBOW LANG for each model)
Note: Do not use the hand degausser; it magnetizes the CRT .
1.  Input white pattern from pattern generator.  Set the PICTURE control 
to maximum, and the BRIGHTNESS control to standard.
2.  Loosen the defl ection yoke mounting screw, and set  the purity 
control to the center as shown below:
Purity Control
3.  Input a green pattern from the pattern generator.
4.  Move the defl ection yoke backwards, (See Figure 1) and adjust with 
the purity control so that green is in the center and red and blue are 
even on both sides. 
The following adjustments should be made when a complete 
realignment is required or a new picture tube is installed. 
These adjustments should be performed with rated power supply 
voltage unless otherwise noted.
The controls and switch should be set as follows unless otherwise 
noted:
VIDEO MODE:  STANDARD (RESET)
Perform the adjustments in order as follows:
 
1.  Beam Landing
 
2.  Convergence
 
3.  Focus
 
4.  Screen (G2)
 
5.  White Balance
Test Equipment Required:
 
1.  Color Bar Pattern Generator
 
2.  Degausser
 
3.  DC Power Supply
 
4.  Digital Multimeter
Figure 1
(Check Areas)
27
KV-27HS420/29DRC430/30HS420/32HS420/34HS420
KV-27HS420/29DRC430/30HS420/32HS420/34HS420
2-2.  V-PIN AND V-CEN ADJUSTMENT
Preparation:
•  Input a cross hatch pattern signal.
•  Set Video Mode to: Standard (Reset)
•  For all 4x3 CRT, VPIN data has separate register for full and 
 
V-compress. Adjust both modes if needed.
•  For all 16x9 CRT’s, adjust VPIN in normal mode for straightness of 
horizontal line.
1.  Adjust service mode CXA2170D-1 05 V-CEN so that the top pin and 
bottom pin are symmetrical from top to bottom.
2.  Adjust service mode CXA2170D-1 06 V-PIN so that the top pin and 
bottom pin are symmetrical from top to bottom.
3.  Horizontal lines should be straight from left to right.  Check landing for 
side effect.
2-3. CONVERGENCE
Preparation:
•  Set the CONTRAST and BRIGHTNESS control to standard (reset).
•  Input a cross hatch pattern signal.
2-3.1.  VERTICAL AND HORIZONTAL STATIC 
CONVERGENCE
1.  Set dynamic convergence to default values (as in 2-1 Beam Landing) 
or disconnect the dynamic convergence before adjusting static 
convergence (CN903), except for minor touch-up.
2.  Adjust H.STAT convergence, RV9001, on CH Board to converge 
 
red, green, and blue dots in the center of the screen.
3.  Adjust V. STAT magnet to converge red, green and blue dots in the 
center of the screen.
R
G
B
Center dot
RV9001
H-STAT
V.STAT magnet
R   G   B
4.  Tilt the V.STAT magnet and adjust static convergence to open or 
close the V.STAT magnet.
B
G
R
B
G
R
1
2-3.2.  OPERATION OF BMC (HEXAPOLE) 
MAGNET
The respective dot positions result from moving each magnet interact.  
Perform the following adjustments while tracking.
1.  Use the BMC tabs to adjust the red, green and blue dots so that 
they line up at the center of the screen (move the dots in a horizontal 
direction).
HMC Correction
HMC Correction
R
G
B
A=B
A
B
R
G B
A>B
A
B
R
G
B
A=B
A
B
R
G
B
A<B
A
B
VMC Correction
R
G
B
C<D
C
D
R
G
B
C=D
VMC Correction
R
G
B
C<D
C
D
R
G
B
C=D
2-3.3. TLH PLATE ADJUSTMENT
Preparation:
•  Input a cross hatch pattern signal.
•  Adjust unbalanced horizontal convergence of red and blue dots by 
adjusting the TLH Plate on the defl ection yoke.
TLH Plate
RV9001
WY Board
CH Board
TLV
XCV
TLH+
TLH-
R B
(B)(R)
B R
(R)(B)
1.  Adjust XCV core to balance X axis.
2.  Adjust the vertical red and blue convergence with V.TILT (TLV VR).
 
Note: Perform adjustments while tracking Item 1.
 Note: 
Restore dynamic convergence when static convergence 
adjustments are complete.
28
KV-27HS420/29DRC430/30HS420/32HS420/34HS420
KV-27HS420/29DRC430/30HS420/32HS420/34HS420
2-3.4. SCREEN-CORNER CONVERGENCE
Preparation:
•  Input a cross hatch pattern signal.
1. Affi x a permalloy assembly corresponding to the misconverged areas.
d
c
a
b
a-d: screen-corner
misconvergence
a
b
c
d
2-3.5. DYNAMIC CONVERGENCE 
ADJUSTMENTS
•  Set dynamic convergence using the following service registers. Note 
areas of change.
•  Only H-component can be corrected, for vertical component use 
permalloy to compensate.
0. YBWU (Upper Y-BOW)
B R
B R
1.  YBWL (Lower  Y BOW)
B R
B R
2.  RSAP (Right H AMP)
R B
3.  RUBW (Right Upper BOW)
B R
4.  RUMB (Right Upper Middle BOW)
B R
5.  RLBW (Right Lower BOW)
R B
6.  RLMB (Right Lower Middle BOW)
B R
7.  LSAP (Left H AMP)
B R
8.  LUBW (Left Upper BOW)
B R
9.  LUMB (Left Upper Middle BOW)
B R
10.  LLBW (Left Lower BOW)
B R
11.  LLMB (Left Lower Middle BOW)
B R
12.  CADJ Fix 29
29
KV-27HS420/29DRC430/30HS420/32HS420/34HS420
KV-27HS420/29DRC430/30HS420/32HS420/34HS420
2-4. FOCUS ADJUSTMENT
Confi rm neck assembly Z axis position. (See Figure 1)
1.  Input a dot signal.
2.  Set Video Mode to STANDARD.
3.  Adjust focus VR counter clockwise (Over-Focus) to confi rm the dot’s 
shape. Center should be very slightly oval with left and right sides 
balanced. 
4.  Input a HD monoscope signal.
5.  Confi rm center focus with focus VR.
KV-32/34 HS420
CRT: 
34RSN/36RV2 (NON-super-fi ne pitch and round fannel)
Neck Assy:NA328 (VA-type, square pin assignment, VPIN harness)
G3
G2
Neck-Ass y: NA3 28
G1
G1 Cu p Hol der
Center T olerance: +/- 0.5mm
KV-27/30 HS420
CRT: 
29RSN/32RVE (NON-Super-Fine Pitch)
Neck Assy:NA2920 (VA-Type, Square pin assignment, VPIN harness)
Neck-Assy: NA2920
G3
G2
Edge of G2 part
Center Step
G1
Position tolerance: + /- 0. 5mm
 
Focus
Screen (G2)
HVD
Over Focus
DQP Dot Pattern
Note: Changing neck assembly position will affect corner convergence.
2-4.1.  DYNAMIC FOCUS/DYNAMIC QUADRA-
POLE DATA
Normally, no adjustments are necessary for these systems. If for some 
reason the data is lost, use the data from Table 1 below:
1. Write the data from any non-vertically compressed mode, then  
 
  use the CPY1 function (CXA2170D-4 Item 6) to copy the data to the  
  vertical compressed modes. 
  Note: V-compressed data is identical to non-v-compressed  
 
  data. Service personnel with a trained eye can adjust the DF or  
 
  DQP registers to adjust DF phase (Item 7) or DQP phase (Item 8),    
  respectively, to balance left and right focus. Refrain from adjusting    
  more than 5 steps from table data below. Further adjustment indicates  
  a circuit problem -- troubleshoot to cause. 
  CAUTION: Be sure that Neck Assembly is in the proper location.    
  Mark position before moving or replacing neck assembly.
(See Section 2-4 Figure 1 - before changing DF/DQP data or 
troubleshooting circuit when DF/DQP is suspect.)
Procedure to adjust or check:
1. Short Q8018 B-Gnd to disable DF. B Mark is on the circuit board.    
  Circuit connection changes should always be done with the power off.  
  CAUTION: Q8018 heatsink is live and peak voltage is 250V.
2. Input a cross hatch signal.
3. Change CXA2170-P2 item 2 RGBS to 2 to make green only.
  1. Overfocus to adjust DQP phase. Adjust the data  
 
 
    (CXA2170-D4 item 8) to balance left and right vertical line width.
  2. Once DQP is balanced, remove the short from DF circuit and  
 
    refocus the set.
  3. Adjust DF (CXA2170-D4 item 7) to balance left and right vertical    
 line 
width.
  4. Reconfi rm focus performance.
/29
Table 1
Upper Corner
Lower Corner
Center Horizontal Line
Center Dot Slightly Oval
Figure 1