The following adjustments should be made when a complete 
realignment is required or a new picture tube is installed. 
These adjustments should be performed with rated power supply 
voltage unless otherwise noted.
Set the controls as follows unless otherwise noted:
VIDEO MODE: Pro
PICTURE CONTROL: Normal
BRIGHTNESS CONTROL: Normal
SECTION 2:  SET-UP ADJUSTMENTS
Perform the adjustments in order as follows:
 1.  Beam 
Landing
 2.  Convergence
 3.  Focus
 4.  Screen 
(G2)
 5.  White 
Balance
Note Test Equipment Required:
 
1. 
Color Bar Pattern Generator
 2.  Degausser
 
3. 
DC Power Supply
 4.  Digital 
Multimeter
2-1. BEAM LANDING
Before beginning adjustment procedure:
1.  Feed in the white pattern signal.
ADJUSTMENT PROCEDURE
1.  Input a raster signal with the pattern generator.
2.  Loosen the defl ection yoke mounting screw, and set the purity 
control to the center as shown below:
Purity Control
3.  Turn the raster signal of the pattern generator to green.
4.  Move the defl ection yoke backward, and adjust with the purity control 
so that green is in the center and red and blue are even on both 
sides. 
Blue Red
Green
5.  Move the defl ection yoke forward, and adjust so that the entire 
screen becomes green. 
6.  Switch over the raster signal to red and blue and confi rm the 
condition.
7.  When the position of the defl ection yoke is determined, tighten it with 
the defl ection yoke mounting screw.
8.  If landing at the corner is not right, adjust by using the disk magnets. 
a
c
b
d
b
a
c
d
Purity control
corrects this area.
Disk magnets
or rotatable disk
magnets correct
these areas (a-d).
Deflection yoke positioning
corrects these areas.
32
KV-27FS320/32FS120/32FS320/34FS120/36FS120/36FS320/38FS120
KV-27FS320/32FS120/32FS320/34FS120/36FS120/36FS320/38FS120
2-2. CONVERGENCE
Before starting convergence adjustments:
1  Perform FOCUS, VLIN and VSIZE adjustments.
2.  Set BRIGHTNESS control to minimum.
3.  Feed in dot pattern.
VERTICAL STATIC CONVERGENCE
1.  Adjust V. STAT magnet to converge red, green and blue dots in the 
center of the screen. 
2.  Tilt the V. STAT magnet and adjust static convergence to open or 
close the V. STAT magnet.
 
When the V. STAT magnet is moved in the direction of arrow a and b, 
red, green, and blue dots move as shown below:
B
R
G
B
R
G
R
G B
B
G R
1
2
b
b
b
b
b
b
b
a
a
b
a
a
a
a
3
R
G
B
B
G
R
HORIZONTAL STATIC CONVERGENCE
If the blue dot does not converge with the red and green dots, perform 
the following:
1.  Move H STAT VR magnet (a) to correct insuffi cient H.Static 
convergence.
BMC MA
GNET
PURITY
V.STAT
H STAT VR
B
G
R
Center dot
V.STAT magnet
RV701
H.STAT
B
G
R
33
KV-27FS320/32FS120/32FS320/34FS120/36FS120/36FS320/38FS120
KV-27FS320/32FS120/32FS320/34FS120/36FS120/36FS320/38FS120
DYNAMIC CONVERGENCE  ADJUSTMENT
Before performing this adjustment, perform Horizontal  and Vertical Static 
Convergence Adjustment.
1.  Slightly loosen defl ection yoke screw.
2.  Remove defl ection yoke spacers.
3.  Move the defl ection yoke for best convergence as  
 
shown below:
B
G
R
G
B
R
G
B
R
R
R
G
B
G
B
G
B
R
B
G
R
G
B
G
B
R
R
G
B
G
G
B
R B
R
R
4.  Tighten the defl ection yoke screw.
5.  Install the defl ection yoke spacers.
TLH PLATE ADJUSTMENT
1.  Input crosshatch pattern.
2.  Adjust PICTURE QUALITY to standard, PICTURE and BRIGHTNESS 
to 50%, and OTHER to standard.
3  Adjust the Horizontal Convergence of red and blue dots by tilting the 
TLH plate on the defl ection yoke.
(TLV)
YCH
XCV
TLV
C
Board
RV701
 V.STAT
TLH Plate
  B R      R B
(R)(B)  (B)(R)
TLH+
TLH-
4.  Adjust XCV core to balance X axis.
5.  Adjust YCH VR to balance Y axis.
6.  Adjust vertical red and blue convergence with V.TILT (TLV VR.) 
 
Note: Perform adjustment 3-6 while tracking items 1 and 2.
SCREEN-CORNER CONVERGENCE
1.  Affi x a permalloy assembly corresponding to the misconverged areas: 
b
a
c
d
a
b
d
a-d: screen-corner
misconvergence
c
2-3. FOCUS
1.  Adjust FOCUS control for best pictures.
Focus (FV)
Screen (G2)
Page of 127