DOWNLOAD Sony KV-21FK120 Service Manual ↓ Size: 5.9 MB | Pages: 61 in PDF or view online for FREE

Model
KV-21FK120
Pages
61
Size
5.9 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
kv-21fk120.pdf
Date

Sony KV-21FK120 Service Manual ▷ View online

18
KV-21FK120
KV-21FK120
2-2. CONVERGENCE
Before starting convergence adjustments:
1  Perform FOCUS, VLIN and VSIZE adjustments.
2.  Set BRIGHTNESS control to minimum.
3.  Feed in dot pattern.
Vertical Static Convergence
1.  Adjust V. STAT magnet to converge red, green and blue dots in the 
center of the screen (Vertical movement adjust S V.STAT RV1750 to 
converge).
B
G
R
Center dot
V.STAT magnet
RV1750
V.STAT
B
G
R
2.  Tilt the V. STAT magnet and adjust static convergence to open or 
close the V. STAT magnet.
 
When the V. STAT magnet is moved in the direction of arrow a and b, 
red, green, and blue dots move as shown below:
B
R
G
B
R
G
R
G B
B
G R
1
2
b
b
b
b
b
b
b
a
a
b
a
a
a
a
3
R
G
B
B
G
R
Horizontal Static Convergence
If the blue dot does not converge with the red and green dots, peform 
the following:
1.  Move BMC magnet (a) to correct insuffi cient H.Static convergence.
2.  Rotate BMC magnet (b) to correct insuffi cient V.Static convergence.
3.  After adjusting the BMC magnet, repeat Beam Landing Adjustment.
BMC
 MA
GNET
PURITY
V.STAT
b
BMC magnet
a
19
KV-21FK120
KV-21FK120
Dynamic Convergence Adjustment
Before performing this adjustment, perform Horizontal  and Vertical 
Static Convergence Adjustment.
1.  Slightly loosen defl ection yoke screw.
2.  Remove defl ection yoke spacers.
3.  Move the defl ection yoke for best convergence as  
 
shown below:
B
G
R
G
B
R
G
B
R
R
R
G
B
G
B
G
B
R
B
G
R
G
B
G
B
R
R
G
B
G
G
B
R B
R
R
4.  Tighten the defl ection yoke screw.
5.  Install the defl ection yoke spacers.
TLH Plate Adjustment
1. Input crosshatch pattern.
2.  Adjust PICTURE QUALITY to standard, PICTURE and 
BRIGHTNESS to 50%, and OTHER to standard.
3  Adjust the Horizontal Convergence of red and blue dots by tilting the 
TLH plate on the defl ection yoke.
YCH
TLV
CV
Board
RV1750
 V.STAT
TLH Plate
  B R      R B
(R)(B)  (B)(R)
TLH+
TLH-
4.  Adjust XCV core to balance X axis.
5.  Adjust YCH VR to balance Y axis.
6.  Adjust vertical red and blue convergence with V.TILT (TLV VR.) 
 
Note: Perform adjustment 3-6 while tracking items 1 and 2.
Screen-Corner Convergence
1.  Affi x a permalloy assembly corresponding to the misconverged areas: 
b
a
c
d
a
b
d
a-d: screen-corner
misconvergence
c
2-3. FOCUS
1.  Adjust FOCUS control for best pictures.
Focus (FV)
Screen (G2)
20
KV-21FK120
KV-21FK120
2-4. SCREEN (G2)
1.  Input a dot pattern.
2.  Set the PICTURE and BRIGHTNESS controls at minimum and 
COLOR control at normal.
3.  Adjust SBRT, GCUT, BCUT in service mode with an oscilloscope as 
shown below so that voltages on the red, green, and blue cathodes 
are 160 ± 2VDC.
Pedestal
160 – 2VDC
Ground
±
4.  Observe the screen and adjust SCREEN (G2) VR in FBT to obtain 
the faintly visible background of dot signal. 
21
KV-21FK120
KV-21FK120
3-1.  X R565 CONFIRMATION METHOD 
(HV HOLD-DOWN CONFIRMATION) AND 
READJUSTMENTS
The following adjustments should always be performed when replacing 
the following components which are marked with Y on the schematic 
diagram:
DY, T585, CRT, IC001, IC561,
IC600, C506, C507, C508, T511,
L510, C588, L588, C566, C561,
C563, D567, D568, D566, PH602,
R567, R568, R565, R566, R562,
R563, R561, R528……....A Board
HV HOLD-DOWN
R565
Part Replaced (Y)
Adjustment (X)
Preparation Before Confi rmation
1.  Using a Variac, apply AC input voltage: 120 ± 2 VAC.
2.  Turn the POWER switch ON.
3.  Input a white signal and set the PICTURE and BRIGHTNESS 
controls to maximum.
4.  Confi rm that the voltage between C566 (+) or TP30 and ground is 
more than 97 VDC.
Hold-Down Operation Confi rmation
1.  Connect the current meter between Pin 11 of the FBT (T585) and the 
PWB land where Pin 11 would normally attach (See Figure 1 on the 
next page).
2.  Input a dot signal and set PICTURE and BRIGHTNESS to minimum: 
IABL = 100 ± 100µA.
3.  Confi rm the voltage of A Board TP-23 is 135.6 ± 1VDC.
4.  Connect the digital voltmeter and the DC power supply via Diode 
1SS119 to C566 (+) and ground (See Figure 1 on next page).
5.  Increase the DC power voltage gradually until the picture blanks out.
6.  Turn DC power source off immediately.
7.  Read the digital voltmeter indication standard < 117.0 VDC.
8.  Input a white signal and set PICTURE and BRIGHTNESS to 
maximum: IABL = 1350 ± 100µA.
9.  Repeat steps 4 through 7.
Hold-Down Readjustment
If the setting indicated in Step 2 of Hold-Down Operation Confi rmation 
cannot be met, readjustment should be performed by altering the 
resistance value of R565 component marked with X. 
+
IABL
ABL
T585
FBT
range
-
Ammeter
3.0 mA  DC
A
3-2. B+ VOLTAGE CONFIRMATION AND 
ADJUSTMENT
Note: The following adjustments should always be performed when 
replacing the following components, which are marked with Y on the 
schematic diagram on the A Board:
   A BOARD:       Y  IC600, PH602
1.  Using a Variac, apply AC input voltage: 130 + 2.0 / - 0.0 VAC.
2.  Input a DOT pattern at Q.C.
3.  Set the PICTURE  and the BRIGHTNESS controls to minimum.
4.  Confi rm the voltage of A Board between TP-23 & Ground is =135.6  ± 
1VDC.
5.  If step 4 is not satisfi ed, replace the components listed above, then 
repeat steps 1 through 3. 
SECTION 3:  SAFETY RELATED ADJUSTMENTS
Page of 61
Display

Click on the first or last page to see other KV-21FK120 service manuals if exist.