DOWNLOAD Sony KV-21FA340 Service Manual ↓ Size: 15.17 MB | Pages: 91 in PDF or view online for FREE

Model
KV-21FA340
Pages
91
Size
15.17 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
kv-21fa340.pdf
Date

Sony KV-21FA340 Service Manual ▷ View online

34
KV-21FA340/21FA540/29FA340/29FA540
KV-21FA340/21FA540/29FA340/29FA540
2-4. SCREEN (G2)
1.  Input a dot pattern.
2.  Set the PICTURE and BRIGHTNESS controls at minimum and 
COLOR control at normal.
3.  Adjust SBRT, GCUT, BCUT in service mode with an oscilloscope as 
shown below so that voltages on the red, green, and blue cathodes 
are 172 ± 2VDC.
Pedestal
172 – 2VDC
Ground
±
4.  Observe the screen and adjust SCREEN (G2) VR in FBT to obtain 
the faintly visible background of dot signal. 
35
KV-21FA340/21FA540/29FA340/29FA540
KV-21FA340/21FA540/29FA340/29FA540
SECTION 3:  SAFETY RELATED ADJUSTMENTS
Hold-Down Readjustment
If the setting indicated in Step 2 of Hold-Down Operation Confi rmation 
cannot be met, readjustment should be performed by altering the 
resistance value of R530, R531 component marked with X. 
 
3mA DC range
+
-
+
-
A
+
-
FBT
TP85
T503
FBT
TP85
R531 R530
DC Power Supply
digital multimeter
ammeter
 
 
Figure 1
3-2. B+ VOLTAGE CONFIRMATION AND 
ADJUSTMENT
Always perform the following adjustments when replacing the following 
components, which are marked with Y on the schematic diagram on the 
A Board:
  
A BOARD
IC600, PH602
Adjustment (Y)
1.  Using a Variac, apply AC input voltage: 130 + 2.0/-0.0 VAC
2.  Input a monoscope signal.
3.  Set the PICTURE control and the BRIGHT control to  
 
minimum.
4.  Confi rm the voltage on A Board between TP23 and ground is less 
than 136.5 VDC.
5.  If step 4 is not satisfi ed, replace R530 and R531 on A Board and 
repeat the above steps.  
3-1.  X R530, R531 CONFIRMATION METHOD 
(HV HOLD-DOWN CONFIRMATION) AND 
READJUSTMENTS
The following adjustments should always be performed when replacing 
the following components which are marked with Y on the schematic 
diagram:
C531, C532, D519, D520,
D521, IC501, IC600, PH602,
R529, R530, R531, R532,
R533, R550, T503 (FBT),
T504 (DFT)
HV HOLD-DOWN
R530, R531
Part Replaced (Y)
Adjustment (X)
Preparation Before Confi rmation
1.  Using a Variac, apply AC input voltage: 120 +/- 2.0 VAC.
2.  Turn the POWER switch ON.
3.  Input a white signal and set the PICTURE and BRIGHT controls to 
maximum.
4.  Confi rm that the voltage of more than 23.0 VDC appears between 
TP85 and ground on the A Board.
Hold-Down Operation Confi rmation
1.  Connect the current meter between Pin 11 of the FBT (T503) and the 
PWB land where Pin 11 would normally attach. (See Figure 1).
2.  Input a dot signal and set PICTURE and BRIGHTNESS to minimum: 
IABL = 2175 + 100/ -325 µA.
3.  Confi rm the voltage of A Board TP91 is 134.6 ± 1.0 VDC.
4.  Connect the digital voltmeter and the DC power supply to TP85 and 
ground. (See Figure 1).
5.  Increase the DC power voltage gradually until the picture blanks out.
6.  Turn DC power source off immediately.
7.  Read the digital voltmeter indication:  (standard = 27.24 + 0.0/ - 0.1 
VDC).
8.  Input a white signal and set PICTURE and BRIGHTNESS to 
maximum: IABL = 2175 + 100/ -325 µA.
9.  Repeat steps 4 to 7.
36
KV-21FA340/21FA540/29FA340/29FA540
KV-21FA340/21FA540/29FA340/29FA540
4-1. REMOTE ADJUSTMENT BUTTONS AND 
INDICATORS
VOLUME (+)
(Service Mode)
ENT
(Enter into 
memory)
0
(Remove 
from 
memory)
3
(Adjust) 
Data up
RM-Y194
5
(Display) 
Category 
down
MUTING
(Enter into 
memory)
1
(Display) 
Item up
2
(Display) 
Category up
4
(Display) 
Item down
8
(Initialize)
DISPLAY
(Service Mode)
POWER
(Service Mode)
6
(Adjust) 
Data down
SECTION 4:  CIRCUIT ADJUSTMENTS
Electrical Adjustments by Remote Commander
Use the Remote Commander
 
(RM-Y194) 
to
 perform the circuit adjustments in this section.
Test Equipment Required:   1. Pattern generator   2. Frequency counter   3. Digital multimeter  4. Audio oscillator
4-2. ACCESSING THE SERVICE 
ADJUSTMENT MODE
1.  Standby mode (Power off).
2.  Press the following buttons on the remote commander within a 
second of each other: 
 
DISPLAY
  
 Channel  5      
 Sound Volume  +  
 
 POWER
 
The screen displays the fi rst service data device OSD item.
Signal
Type
Channel
Type
NTSC
VIDEO1
DEF
M6J586MK-050FP
F1.2
HSIZ
1:35                NVM:OK
Device
OSD
Item
Initial
Data
Value
1.  On the Remote Commander press  2  or  5  to select the device.
2. Press 1  or  4  to select the OSD.
3. Press 3  or  6  to change the data value.
4. Press MUTING  then  ENTER  to write into memory.
Signal
Type
Channel
Type
NTSC
WRITE
DEF
M6J586MK-050FP
F1.2
HSIZ
1:35                NVM:OK
Text 
changes to 
“WRITE” and 
changes 
colors from 
green to red
Device
OSD
Item
Initial
Data
Value
37
KV-21FA340/21FA540/29FA340/29FA540
KV-21FA340/21FA540/29FA340/29FA540
Service Adjustment Mode Memory
Use the following procedure when adjusting IDs 0-7 and when replacing 
and adjusting IC002.
1. Access Service Adjustment Mode.
2. Press 8  then  ENTER  on the Remote Commander to initialize.
Signal
Type
Channel
Type
NTSC
RESET
DEF
M6J586MK-050FP
F1.2
HSIZ
1:35                NVM:OK
Text 
changes to 
“RESET” 
and changes 
colors from 
green to red
Device
OSD
Item
Initial
Data
Value
The TV powers off after completing the initialization process.
4-3. CONFIRMING SERVICE ADJUSTMENT 
CHANGES
1.  After completing adjustments, pull out the plug from the AC outlet, 
then replace the plug in the AC outlet again.
2. Access Service Adjustment Mode.
3.  Using the buttons on the Remote Commander, locate the adjusted 
OSD items again to confi rm they were adjusted.
Page of 91
Display