18
KV-21FA310/21FV210/29FA310/29FS110/29FV210
KV-21FA310/21FV210/29FA310/29FS110/29FV210
SECTION 3:  SAFETY RELATED ADJUSTMENTS
Hold-Down Readjustment
If the setting indicated in Step 2 of Hold-Down Operation Confi rmation 
cannot be met, readjustment should be performed by altering the 
resistance value of R530, R531 component marked with X. 
 
3mA DC range
+
-
+
-
A
+
-
FBT
TP85
T503
FBT
TP85
R531 R530
DC Power Supply
digital multimeter
ammeter
 
 
Figure 1
3-2. B+ VOLTAGE CONFIRMATION AND 
ADJUSTMENT
Always perform the following adjustments when replacing the following 
components, which are marked with Y on the schematic diagram on the 
AW Board:
  
AW BOARD
IC600, PH602
Adjustment (Y)
1.  Using a Variac, apply AC input voltage: 130 + 2.0/-0.0 VAC
2.  Input a monoscope signal.
3.  Set the PICTURE control and the BRIGHT control to  
 
minimum.
4.  Confi rm the voltage on AW Board between TP23 and ground is less 
than 136.5 VDC.
5.  If step 4 is not satisfi ed, replace R530 and R531 on AW Board and 
repeat the above steps.  
3-1.  X R530, R531 CONFIRMATION METHOD 
(HV HOLD-DOWN CONFIRMATION) AND 
READJUSTMENTS
The following adjustments should always be performed when replacing 
the following components which are marked with Y on the schematic 
diagram:
C531, C532, D519, D520,
D521, IC501, IC600, PH602,
R529, R530, R531, R532,
R533, R550, T503 (FBT),
T504 (DFT)
HV HOLD-DOWN
R530, R531
Part Replaced (Y)
Adjustment (X)
Preparation Before Confi rmation
1.  Using a Variac, apply AC input voltage: 120 +/- 2.0 VAC.
2.  Turn the POWER switch ON.
3.  Input a white signal and set the PICTURE and BRIGHT controls to 
maximum.
4.  Confi rm that the voltage of more than 23.0 VDC appears between 
TP85 and ground on the AW Board.
Hold-Down Operation Confi rmation
1.  Connect the current meter between Pin 11 of the FBT (T503) and the 
PWB land where Pin 11 would normally attach. (See Figure 1).
2.  Input a dot signal and set PICTURE and BRIGHTNESS to minimum: 
IABL = 2175 + 100/ -325 µA.
3.  Confi rm the voltage of AW Board TP91 is 134.6 ± 1.0 VDC.
4.  Connect the digital voltmeter and the DC power supply to TP85 and 
ground. (See Figure 1).
5.  Increase the DC power voltage gradually until the picture blanks out.
6.  Turn DC power source off immediately.
7.  Read the digital voltmeter indication: 
(standard = 27.24 + 0.0/ - 0.1 VDC).
8.  Input a white signal and set PICTURE and BRIGHTNESS to 
maximum: IABL = 2175 + 100/ -325 µA.
9.  Repeat steps 4 to 7.
19
KV-21FA310/21FV210/29FA310/29FS110/29FV210
KV-21FA310/21FV210/29FA310/29FS110/29FV210
4-1.  REMOTE ADJUSTMENT BUTTONS AND 
INDICATORS
VOLUME (+)
(Service Mode)
6
Decrease 
Data value
ENTER
(Enter into 
memory)
0
(Remove from 
memory)
3
Increase 
Data value
RM-Y195
5
Display previous 
Device
MUTING
(Enter into 
memory)
1
Display next 
OSD item
2
Display next 
Device
4
Display previous
 OSD item
8
(Initialize)
DISPLAY
(Service Mode)
POWER
(Service Mode)
SECTION 4:  CIRCUIT ADJUSTMENTS
Electrical Adjustments by Remote Commander
Use the Remote Commander
 
(RM-Y194 or RM-Y195) 
to
 perform the circuit adjustments in this section.
Test Equipment Required:   1. Pattern generator   2. Frequency counter   3. Digital multimeter  4. Audio oscillator
4-2.  ACCESSING THE SERVICE 
ADJUSTMENT MODE
1.  Standby mode (Power off).
2.  Press the following buttons on the remote commander within a 
second of each other: 
 
DISPLAY
  
 Channel  5      
 Sound Volume  +  
 
 POWER
 
The screen displays the fi rst service data device OSD item.
Signal
Type
Channel
Type
NTSC
VIDEO1
DEF
M6J586MK-050FP
F1.2
HSIZ
1:35                NVM:OK
Device
OSD
Item
Initial
Data
Value
1.  On the Remote Commander press  2  or  5  to select the device.
2. Press 1  or  4  to select the OSD.
3. Press 3  or  6  to change the data value.
4. Press MUTING  then  ENTER  to write into memory.
Signal
Type
Channel
Type
NTSC
WRITE
DEF
M6J586MK-050FP
F1.2
HSIZ
1:35                NVM:OK
Text 
changes to 
“WRITE” and 
changes 
colors from 
green to red
Device
OSD
Item
Initial
Data
Value
20
KV-21FA310/21FV210/29FA310/29FS110/29FV210
KV-21FA310/21FV210/29FA310/29FS110/29FV210
Service Adjustment Mode Memory
Use the following procedure when adjusting IDs 0-7 and when replacing 
and adjusting IC002.
1.  Access Service Adjustment Mode.
2. Press 8  then  ENTER  on the Remote Commander to initialize.
Signal
Type
Channel
Type
NTSC
RESET
DEF
M6J586MK-050FP
F1.2
HSIZ
1:35                NVM:OK
Text 
changes to 
“RESET” 
and changes 
colors from 
green to red
Device
OSD
Item
Initial
Data
Value
The TV powers off after completing the initialization process.
4-3. CONFIRMING SERVICE ADJUSTMENT 
CHANGES
1.  After completing adjustments, pull out the plug from the AC outlet, 
then replace the plug in the AC outlet again.
2.  Access Service Adjustment Mode.
3.  Using the buttons on the Remote Commander, locate the adjusted 
OSD items again to confi rm they were adjusted.
21
KV-21FA310/21FV210/29FA310/29FS110/29FV210
KV-21FA310/21FV210/29FA310/29FS110/29FV210
4-4.  SERVICE DATA LISTS
Device "DEF"
Item#
OSD
DETAIL
Initial Data
(DEC) 21"
NTSC/RF   NTSC/YUV
Initial Data
(DEC) 21"
PAL M    PAL N
Initial Data
(DEC) 29"
NTSC/RF   NTSC/YUV
Initial Data
(DEC) 29"
PAL M    PAL N
VAR: 1
HSIZ
H SIZE(EW DC)
43                43
43                  43
41                   41
40              39
VAR: 2
HPOS
H POSITION
16                 17
13                    13
9                    14
14              19
VAR: 3
VSIZ
V RAMP SIZE
31                  32
31                    31
35                  37
36               37
VAR: 4
VPOS  
V POSITION(RAMP DC)
32                  31
31                    31
33                  32
33               33
VAR: 5
VLIN
V LINEARITY
39                 39
39                   39
33                  36
47               33
VAR: 6
SCOR
S CORRECTION
33                  33
33                   33
50                   41
44               50
VAR: 7
VBOW
BOW
29                  29
29                   29
32                   36
35               30
VAR: 8
VANG
ANGLE
32                  32
32                    32
34                   37
36                40
VAR: 9
TRAP
EW TRAPESIUM
40                   40
40                    40
29                   27
32                29
VAR: 10
PAMP
EW PIN
21                    21
21                     21
28                   26
28                26
VAR: 11
UPIN
UPPER PIN
34                  35
34                    34
29                   30
31                29
VAR: 12
LPIN
LOWER PIN
34                  33
33                    33
30                    31
28                30
VAR: 13
TROT
TROT
109
109
VAR: 14
HBLK
H BLK mode select
00
00
VAR: 15
RBLK
HBLK rear timing
28                  28
28                    28
28                  28
34                34
VAR: 16
LBLK
HBLK front timing
54                  54
54                    54
54                  54
60                60
VAR: 17
VBLK
V BLK width
03
03
18
HMSK
TOP VEND(when MACROVISION)prevent OFF
00
00
19
HDW
H PULSE WIDTH(25u    19u)
01
01
20
AFC
AFC GAIN
00
00
21
AFC1
AFC1 TIME CONSTANT
RF/03   AV/03    YUV/03
RF/03  AV/03 YUV/03
22
AFCW
AFC1 PULL IN WIDE
01
01
23
CDMD
V DET WINDOW SW TIMING
01
01
24
HSS
SYNC SLICE LEVEL(H sepa)
00
00
25
VSS
SYNC SLICE LEVEL(V sepa)
03
03
26
SLUD
Auto Slice level UP    DOWN
00
00
27
JPSW
Jump SW
00
00
28
HOSC
H VCO fo offset ADJUST OFFSET
03
03
29
EHT
EHT
04
04
30
EHTG
EHT MODE
01
01
31
SLOH
LPF SYNC H
01
01
32
SLOV
LPF SYNC V
03
03
33
SLOP
LPF SYNC 
01
01
34
SLVC
LPF SYNC VCOIN OFF
00
00
35
SLHC
LPF SYNC HCOIN OFF
00
00
Page of 124