— 9 —
KV-21FA210
1-1.  REAR COVER REMOVAL
SECTION 1:  DISASSEMBLY
1-2.  CHASSIS ASSEMBLY REMOVAL
1-3.  SERVICE POSITION
Chassis Assembly
Claw
Screws +BVTP 4X16 TYPE2 TT(B)
Rear Cover
A Board
KB Board
CV Board
1
Unplug  KB  Board    and  2  pin  woofer  connector  and  move  out  of                      
the way.
2
Press on catch tab to release A Board.
3
Disconnect remaining cables to allow A Board to be removed. 
— 10 —
KV-21FA210
1.  Discharge the anode of the CRT and remove the anode cap.
2.  Unplug all interconnecting leads from the defl ection yoke, neck 
assembly, degaussing coils and CRT grounding strap.
3.  Remove the CV Board from the CRT.
4.  Remove the chassis assembly.
5.  Loosen the neck assembly fi xing screw and remove.
6.  Loosen the defl ection yoke fi xing screw and remove.
7.  Place the set with the CRT face down on a cushion and remove 
the degaussing coil holders.
8.  Remove the degaussing coils.
9.  Remove the CRT grounding strap and spring tension devices.
10. Unscrew the four CRT fi xing screws [located on each CRT 
corner] and remove the CRT  [Take care not to handle the CRT 
by the neck].
1-4.  PICTURE TUBE REMOVAL
WARNING: BEFORE REMOVING THE ANODE CAP
High voltage remains in the CRT even after the power is disconnected. To avoid electric shock, 
discharge CRT before attempting to remove the anode cap. Short between anode and CRT 
coated earth ground strap.
Coated
Earth
Ground 
Strap
ANODE CAP REMOVAL PROCEDURE
WARNING: High voltage remains in the CRT even after the power is disconnected. To avoid electric shock, discharge CRT before attempting to  
remove the anode cap.  Short between anode and coated earth ground strap of CRT. 
NOTE:  After removing the anode cap, short circuit the anode of the picture tube and the anode cap to either the metal chassis, CRT shield, or carbon 
painted on the CRT. 
REMOVAL PROCEDURES
HOW TO HANDLE AN ANODE CAP
1.  Do not use sharp objects which may cause damage to the surface of the anode 
cap. 
2.  To avoid damaging the anode cap, do not squeeze the rubber covering too 
hard. A material fi tting called a shatter-hook terminal is built into the rubber. 
3.  Do not force turn the foot of the rubber cover. This may cause the shatter-hook 
terminal to protrude and damage the rubber.
10
6
5
4
3
1
2
Turn up one side of the rubber cap in 
the direction indicated by arrow  a  .
Use your thumb to pull the rubber
cap fi rmly in the direction indicated
by arrow  b  .
When one side of the rubber cap separates from 
the anode button, the anode cap can be removed 
by turning the rubber cap and pulling it in the 
direction of arrow  c  .
8
7
9
a
b
Anode Button
c
— 11 —
KV-21FA210
The following adjustments should be made when a complete 
realignment is required or a new picture tube is installed. 
These adjustments should be performed with rated power supply 
voltage unless otherwise noted.
Set the controls as follows unless otherwise noted:
VIDEO MODE: Standard
PICTURE CONTROL: Normal
BRIGHTNESS CONTROL: Normal
SECTION 2:  SET-UP ADJUSTMENTS
Perform the adjustments in order as follows:
  1. 
Beam Landing
  2. 
Convergence
  3. 
Focus
  4. 
Screen (G2)
  5. 
White Balance
Note Test Equipment Required:
  1. 
Color Bar Pattern Generator
  2. 
Degausser
  3. 
DC Power Supply
  4. 
Digital Multimeter
2-1.  BEAM LANDING
Before beginning adjustment procedure:
1.  Degauss the entire screen.
2.  Feed in the white pattern signal.
ADJUSTMENT PROCEDURE
1.  Input a raster signal with the pattern generator.
2.  Loosen the deflection yoke mounting screw, and set the purity 
control to the center as shown below:
Purity Control
3.  Turn the raster signal of the pattern generator to green.
4.  Move the deflection yoke backward, and adjust with the purity control 
so that green is in the center and red and blue are even on both 
sides. 
���� ���
�����
5.  Move the deflection yoke forward, and adjust so that the entire 
screen becomes green. 
6.  Switch over the raster signal to red and blue and confirm the 
condition.
7.  When the position of the deflection yoke is determined, tighten it with 
the deflection yoke mounting screw.
8.  If landing at the corner is not right, adjust by using the disk magnets. 
a
c
b
d
b
a
c
d
Purity control
corrects this area.
Disk magnets
or rotatable disk
magnets correct
these areas (a-d).
Deflection yoke positioning
corrects these areas.
— 12 —
KV-21FA210
2-2.  CONVERGENCE
Before starting convergence adjustments:
1  Perform FOCUS, VLIN and VSIZE adjustments.
2.  Set BRIGHTNESS control to minimum.
3.  Feed in dot pattern.
VERTICAL STATIC CONVERGENCE
1.  Adjust V. STAT magnet to converge red, green and blue dots in the 
center of the screen (Vertical movement adjust S V.STAT RV1750 to 
converge).
B
G
R
Center dot
V.STAT magnet
RV1750
V.STAT
B
G
R
2.  Tilt the V. STAT magnet and adjust static convergence to open or 
close the V. STAT magnet.
  When the V. STAT magnet is moved in the direction of arrow a and b, 
red, green, and blue dots move as shown below:
B
R
G
B
R
G
R G B
B G R
1
2
b
b
b
b
b
b
b
a
a
b
a
a
a
a
3
R
G
B
B
G
R
HORIZONTAL STATIC CONVERGENCE
If the blue dot does not converge with the red and green dots, peform 
the following:
1.  Move BMC magnet (a) to correct insufficient H.Static convergence.
2.  Rotate BMC magnet (b) to correct insufficient V.Static convergence.
3.  After adjusting the BMC magnet, repeat Beam Landing Adjustment.
BMC MA
GNET
PURITY
V.STAT
b
BMC magnet
a
Page of 100
Display

Click on the first or last page to see other KV-21FA210 (serv.man2) service manuals if exist.