– 9 –
KP-FR43M31/FR43M91
   RM-GA001
2-10. A, D AND G1 BOARDS REMOVAL
2-9.
AD, BH, DS, MG AND T BOARDS REMOVAL
2-11. CRT AND PWB BLOCK REMOVAL
2
 BH board
1
 T board
 
6
 MG Board
4
 DS board
3
 Two screws
 
(BVTP 3x12
 
Type2 IT-3)
 5
 AD Board
Main bracket section
8
 D board
6
 A board
4
 G1 bracket
3
 Three screws
 
(BVTP 3x12
 
Type2 IT-3)
1
 Two screws
 
(BVTP 3x12
 
Type2 IT-3)
7
 Six screws
 
(BVTP 3x12)
5
 Six screws
 
(BVTP 3x12)
2
 G1 board
Main bracket section
PWB block assy
3
 Picture tube block assy
4
 Two screws
 
(Hexagon head)
 
(4x20)
5
 Three screws
 
(Hexagon head)
 
(4x20)
2
 Three screws
 
(Hexagon head)
 
(4x20)
6
 Two screws
 
(BVTP 4x16)
1
 Two screws
 
(BVTP 4x16)
– 10 –
KP-FR43M31/FR43M91
   RM-GA001
2-12. HIGH-VOLTAGE CABLE INSTALLATION AND REMOVAL
1
 Rubber cap
2
 HV cable turn 90
1
 Rubber cap
2
 HV cab
Hook
Gutter
(1) Remover
(2) Installation
2-13. MECHANICAL ASSY REMOVAL
 
5
 Four screws
 
(BVTP 4x16)
1
 Four screws
 
(BVTP 4x16)
Removing the arrow-marked screw (gold color) is strictly inhibited.
If removed, it may cause liquid spill.
2
 CR board
3
 Neck assy
4
 Deflection yoke
6
 Mechaseal assy (R)
– 11 –
KP-FR43M31/FR43M91
   RM-GA001
SECTION 3
SET-UP ADJUSTMENTS
3-1. SCREEN VOLTAGE ADJUSTMENT
(ROUGH ALIGNMENT)
1. Receive the Monoscope signal.
2. Set 50% BRIGHTNESS and minimum PICTURE.
3. Turn the red VR on the focus pack all the way to the left
and then gradually turn it to the right until the point
where you can see the retrace line.
4. Next gradually turn it to the left to the position where the
retrace line disappears.
Fig. 3-1
3-2. SCREEN (G2) ADJUSTMENT
(FINE ADJUSTMENT)
1. Turn on the power of the set.
2. Select VIDEO1 and make no signal input.
3. Supply DC (177.5 0.5V) from external power supply to
KR. (Fig. 3-2)
4. Turn red of G2 VR clockwise, then retrace line appear.
5. Turn G2 VR counter clockwise and set retrace line just
disappear. (Fig. 3-3)
6. Add DC voltage DC (174 0.5V) to KR.
7. Confirm if retrace can be seen.
8. Adjust green and blue at the same method.
Fig. 3-2
Fig. 3-3
B
R
G
B
R
G
SCREEN
FOCUS
Focus Pack
+
Dummy Resister
3k ohm 20W
Power
Supply
Test signal
3-3. BLUE OFFSET ADJUSTMENT
This adjustment item must be ending the G2 adjustment.
1. Input the HD (1080i/60Hz Black) signal into component
in terminal.
2. Set PICTURE 100%, others are normal,
DRC 1250/60Hz.
3. Adjust with SLN so that the blue reference pulse peak
voltage of B terminal (CN1504) enters into standard.
4. Write the adjustment value in the NVM area of
widezoom mode after the adjustment.
3-4. FOCUS ROUGH ADJUSTMENT
1. Connect VIDEO-1 terminal.
2. Receive video dot hatch pattern.
3. Use lens-cover to red and blue.
4. Adjust electric focus. (roughly)
5. Rotate the green lens and adjust to obtain the best lens
focus.
6. Rotate the green focus volume on the focus pack and
adjust to obtain best electrical focus.
7. If focus is not good, repeat 4 process.
8. Repeat above process for red and blue lenses and
electric focus.
9. Fix lens screw.
Fig. 3-4
Fig. 3-5
V
0.05V
2.15
GND (0V)
BLUE REFERENCE PULSE
(UG board CN1504 B5 B)
Item: DE F2 03 SLN
Lens
A
B
Minimize both A and B.
Scanning line visible.
– 12 –
KP-FR43M31/FR43M91
   RM-GA001
3-5. DEFLECTION YOKE TILT  ADJUSTMENT
1. Receive the Monoscope signal.
2. Place the caps on the red and blue lens so that only the
green color.
3. Loosen the deflection yoke setscrew and align the tilt of
the Deflection yoke so that the bars at the center of the
monoscope pattern are horizontal.
4. After aligning the deflection yoke, fasten it securely to
the funnel-shaped portion of the CRT.
5. The tilt of the deflection yoke for red and blue is aligned
the same as was done for green.
Fig. 3-6
3-6. 2-POLE AND 4-POLE MAGNET ADJUSTMENT
3-6-1.
Adjustment of 2-pole magnets
1. Receive the Dot signal (1080i/50Hz) from HD/DVD 1
terminal.
2. Place the caps on the red and blue lens so that only the
green color is shown.
3. Turn the green focus volume of focus pack counter-
clock-wise, so that diameter of the dot become large.
4. Adjust the 2-pole magnet, counter-clockwise and
clockwise center of the dot doesn’t move. (Use focus
volume)
5. Center position is changed by 2-pole magnet
adjustment. So, center magnet adjustment and 2-pole
magnet adjustment are needed tracking adjustment.
6. Repeat same adjustment method for red and blue.
Fig. 3-7
Fig. 3-8
3-6-2.
Green, Red, Blue adjustment of 4-pole magnets
1. Turn Green focus volume of focus pack clockwise.
2. By using 4 pole magnets make the spot size round.
3. Repeat for red and blue.
4. Turn focus pack counter-clockwise and “Just Focus” red,
green and blue.
Fig. 3-9
2-Pole Magnet
VM Coil Assy
Centering Magnet
Anode Cap
4-Pole Magnet
Deflection Yoke
Use the center dot
NG
OK
Left-end dot
(BLUE)
Right-end dot
(BLUE)
3-6-3.
Blue left side dot adjustment of 2-pole Magnets
1. Turn blue focus volume of fucus pack counter-clockwise,
so that diameter of the dot becomes large, and can see
bright core position.
2. Pay attentio to left side dot of the screen. (Fig. 3-10)
3. Adjustment 2 pole magnet, so that bright core position of
dot become center position of dot. (Fig. 3-11)
Fig. 3-10
Fig. 3-11
3-7. BLUE DEFOCUS ADJUSTMENT
1. Receive 1080i/50Hz dot signal from HD/DVD 1 terminal.
2. Set “VIVID” and PICTURE 100%, other 50% and white
balance “COOL” (VM OFF), PIOF: 0.
3. Blue 4 pole: make round in the center of screen.
4. Confirm that center dot focus is adjusted in focus.
(Fig. 3-12a)
5. Adjust blue electrical focus to make the left side spot
nearly round by minimizing width and height. (Slight
overfocus is OK) (Fig. 3-12b)
6. Confirm that the green to blue spot size is within spec.
Blue center dot height shall be   1.2 times the g reen dot
height.
7. Return data to original condition.
Fig. 3-12a
Fig. 3-12b
NG
NG
OK
Use the center dot
Bright Core
Blue 2 Pole magnet
Adjustment Position
Blue 2 Defocus
Adjustment Position 
just focus
OK