Sony KP-57XBR10W / KP-65XBR10W Service Manual ▷ View online

– 53 –
KP-57XBR10W/65XBR10W
RM-Y907
RM-Y907
SUB DEFLECTION ADJUSTMENT ITEM
Adjustment
O : Yes
– : No
[GREEN REGISTRATION ADJUSTMENT]
<GREEN CENTER, SIZE>
1. Select GRN CENT or GRN SIZE with the 1and 4 keys on
the remote commander.
2. Adjust the center of crosshatch line goes the middle vertically
and horizontally (GRN CENT) and set the size correctly (GRN
SIZE) with the joystick on the remote commander.
<GREEN SKEW>
1. Select GRN SKEW with the 1 and 4 keys on the remote
commander.
2. Adjust the crosshatch line goes straight vertically and horizon-
tally with the joystick on the remote commander.
<GREEN PINCUSHION>
1. Select GRN PIN with the 1 and 4 keys on the remote
commander.
2. Adjust the crosshatch line goes straight horizontally with the
joystick on the remote commander.
Note : These are required when either severe miss-adjustment or
data loss occurred.
<FINE ADJUSTMENT>
1. Press 9 key on the remote commander to shift to the fine
adjustment mode.
The green cursor (in the GRN mode) appears on the center of
the screen.
2. Use the 1and 4 keys or the joystick on the remote com-
mander, move the cursor (see below) everywhere you want to
adjust and adjust with the joystic keys on the remote com-
mander.
Marker movement by the 1 and 4 keys:
Press once the joystick the cursor turns green to white.
Then you can move the cursor up and down left and right every
where you want.
GRN
CENT
000
: Middle
000
GRN
SKEW
000
000
GRN
PIN
XXXX
000
Adjustment type
Display
Adjustment item
G
R
B
H/V
H/V
H/V
CENT
CENT
O/O
O/O
O/O
SKEW
SKEW
O/O
O/O
O/O
SIZE
SIZE
O/O
O/O
O/O
LIN
LIN
–/–
O/–
O/–
KEY
KEY
–/–
–/O
–/O
PIN
PIN
–/O
–/O
–/O
– 54 –
KP-57XBR10W/65XBR10W
RM-Y907
RM-Y907
Press once again the joystick the cursor stops and returns
green, you can adjust around the cursor.
3. Press 9 key on the remote commander to shift to the coarse
adjustment mode.
[RED REGISTRATION ADJUSTMENT]
<RED CENTER, SKEW>
1. Cover the blue picture lens with the lens cap to show the green
and red colors.
2. Press 3 key on the remote commander to shift the GRN
mode to the RED mode.
3. Select RED CENT or RED SKEW with the 1 and 4 keys
on the remote commander and adjust while tracking each other
alternately.
4. Adjust the red crosshatch lines go straight vertically and
horizontally and overlaps the green lines with the joystick on
the remote commander.
<RED SIZE, LINEARITY>
1. Select RED SIZE (vertically and horizontally) or RED LIN
(vertically) with the 1 and 4 keys on the remote com-
mander and adjust while tracking each other alternately.
2. Adjust the red crosshatch lines go straight vertically and
horizontally and overlaps the green lines with the joystick on
the remote commander.
<RED KEY, PINCUSHION>
1. Select RED KEY or PINCUSHION with the 1 and 4 keys
on the remote commander and adjust while tracking each other
alternately.
2. Adjust the red crosshatch lines go straight horizontally and
overlaps the green lines
with the joystick on the remote commander.
<FINE ADJUSTMENT>
1. Press 9 key on the remote commander to shift to the fine
adjustment mode.
The red cursor (in the RED mode) appears on the center of the
screen.
2. Use the 1 and 4 keys or the joystick on the remote com-
mander, move the cursor everywhere you want to adjust and
adjust with the joystick on the remote commander.
[BLUE REGISTRATION ADJUSTMENT]
1. Remove the lens cap from the blue picture lens to show full
color.
2. Press 3 key on the remote commander to shift the RED mode
to the BLU mode.
3. Adjust BLU CENT, BLU SKEW, BLU SIZE, BLU LIN, BLU
KEY and BLU PIN in the same procedure of the red registra-
tion adjustment.
[FINAL CHECK]
1. Store the new adjustment (offset) value on the remote control
by pressing [MUTING] and [ENTER].
2. Press the FLASH FOCUS button on the front panel.
(The Offset value is now automatically stored.)
3. Check that no error message appears.
If an error message appears, recheck.
Note : In case of replacing CRTs, adjust the set-up adjustments
(items 3-1 to 3-8) and the registration adjustment (item 3-10).
In case of replacing two or three CRTs at the same time,
replace and adjust one by one.
– 55 –
KP-57XBR10W/65XBR10W
RM-Y907
RM-Y907
*  In case of multiple error, last error is displayed.
[SENSOR POSITION]
• ERROR CODE SCREEN DISPLAY
*  Error code will be displayed on center of screen for 3 seconds.
E 11 B
E 11 B
R. G. B
SENSOR NUMBER
ERROR CODE 10
ERROR
3
0
6
4
7
5
1
2
SCREEN
0 : UPPER SENSOR
1 : LEFT SENSOR
2 : RIGHT SENSOR
3 : LOWER SENSOR
4 : UL SENSOR
5 : UR SENSOR
6 : LL SENSOR
7 : LR SENSOR
• ERROR CODE DISPLAY IN REGI SERVICE MODE
3-11. AUTO REGISTRATION ERROR CODE LIST
00
No Error
10
Sensor Output Level Low
* Check wiring, beam position, sensor.
0 : Upper Center
4 : Upper Left
1 : Middle Left
5 : Upper Right
2 : Middle Right
6 : Lower Left
3 : Lower Center
7 : Lower Right
20
Sensor Output Level High
* Check OP-amp circuit.
0 : Upper Center
4 : Upper Left
1 : Middle Left
5 : Upper Right
2 : Middle Right
6 : Lower Left
3 : Lower Center
7 : Lower Right
30
Adjustment Loop Counter Overflow
* Check the registring information on the convergence board.
40
Regi Data Overflow
* Check the convergence yoke driver ICs.
50
Regi Data Overflow
60
Offset Overflow
* Convergence patterns displayed are out of normal range.
70
Offset Overflow
ERROR
DISCRIPTION
NOTE
CODE
[ERROR CODE LIST]
If an error code is displayed after the set has been fully adjusted, correctly, please check the following items: position, tilt and sizing.  If
either of these adjustments are off, even slightly, the auto-registration pattern will not hit the four sensors properly. This occurs when the
internal generator patterns is being flashed on the screen for the sensors to read.  Therefore, auto registration (called auto-focus) cannot
operate properly causing an error code to be displayed. In order for this function to operate properly, correct position, tilt and size must be
adjusted properly.
PJE            2 9             1 4 0
ERR            
ITEM NUMBER-29
ERROR CODE 40
SENSOR NUMBER
(ONLY "10"or "20")
R.G.B
G-0 (Blank)
R-1
B-2
– 56 –
KP-57XBR10W/65XBR10W
RM-Y907
RM-Y907
4-1. HV REGULATION CIRCUIT CHECK AND
ADJUSTMENT
When replacing the following components marked with 
 on
the schematic diagram always check HV regulation, and if nec-
essary re-adjust.
: R8196, R8232
: C8018,C8064, C8066, C8074, C8082
D8042
IC8002, IC8007, IC8008
Q8022
R8093, R8095, R8096, R8105, R8108
R8112, R8113, R8114, R8128, R8136,
R8138, R8139, R8154, R8157, R8168,
R8173, R8174, R8177, R8178, R8195,
R8196, R8232
T8002 (LOT), T8003 (FBT)
HV BLOCK, D BOARD
[ D BOARD]
4-2. HV HOLD DOWN CIRCUIT OPERATION
CHECK AND ADJUSTMENT
When replacing the following components marked with 
 on
the schematic diagram always check hold-down voltage and if
necessary re-adjust.
: R8194, R8231
: C8018, D8026, D8032, D8035, D8050
IC8006, IC8009, IC8010
Q8021, Q8031
R8092, R8094, R8097, R8109,R8110,R8115,
R8117,R8118, R8121, R8123, R8125, R8129,
R8135, R8140, R8155, R8190, R8191, R8192,
R8193, R8194, R8198, R8231
T8002 (LOT), T8003(FBT)
HV BLOCK, D BOARD
Fig. 4-1
Remove the cap off from
the unused terminal and
connect a static voltmeter
there.
OPERATION CHECK
1. Connect a HV static voltmeter to the unconnected plug of
the high-voltage block.
2. Power on the set.
3. Receive dot signal patterm.
4. Check that the HV static voltmeter is readind 34.0 
±
 0.5kV
dc.
HV HOLD-DOWN ADJUSTMENT
1. Repart step 1 as above.
2. Connect 33k
 variable resistor, set to maximum value, to
CN8007.
3. Power on the set.
4. Receive dot signal pattern.
5. Gradually lower the value of the variable resistor until the
static voltmeter is reading 34.0 
±
 0.5 kVdc.
6. Switch off the set.
7. Remove the VR connected across CN8007, and measure its
value.
8. Solder a resistor value, nearest to the measured value, across
CN8007.
9. Reconfirm operation check.
SECTION 4
SAFETY RELATED ADJUSTMENTS
OPERATION CHECK
1. Connect a HV static voltmeter to the unconnected plug of
the high-voltage block.
2. Connect a 33k
 variable resistor, set to maximum value,
across CN8008.
3. Power on the set.
4. Receive dot signal pattern.
5. Gradually lower the value of the variable resistor and check
that the hold-down circuit operates at a static voltmeter read-
ing of 31.0 
±
 0.5kV dc when the raster disappears.
HV REGULATION ADJUSTMENT
1. REPART STEPS 1 ~ 5 as above.
2. Just at the point hold-down circuit begins to operate switch
off the set.
3. Remove the VR connected across CN8008, and measure it’s
resistance.
4. Solder a resistor value, nearest to the measured value, across
CN8008.
5. Reconfirm operation check.
4-3. +B MAX VOLTAGE CONFIRMATION
The following adjustments should always be performed
when replacing IC6101.
1. Supply 120.0 
±
 2.0VAC  to variable autotransformer.
2. Receive dot signal pattern and set the PICTURE and
BRIGHTNESS settings to their minimum.
3. Confirm the voltage of TP  +B 135V is less than 137.0Vdc.
4. If step 4 not satisfied , replace IC6101 and repeat above steps.
[ G BOARD]
4-4. +B OVP CONFIRMATION
1. Connect a voltmeter to TP. OVP and ground.
2. Supply 120VAC to variable autotransformer.
3. Power on the Set.
4. Supply 150VDC to TP. OVP.
5. Check the OVP is activated.
Page of 127