DOWNLOAD Sony KLV-46W380A / KLV-46X300A / KLV-52W380A / KLV-52X300A Service Manual ↓ Size: 14.24 MB | Pages: 87 in PDF or view online for FREE

Model
KLV-46W380A KLV-46X300A KLV-52W380A KLV-52X300A
Pages
87
Size
14.24 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
klv-46w380a-klv-46x300a-klv-52w380a-klv-52x300a.pdf
Date

Sony KLV-46W380A / KLV-46X300A / KLV-52W380A / KLV-52X300A Service Manual ▷ View online

KLV-46/52X300A, 46/52W380A (CH)     3-3
TV micro (on AG board) is monitoring BE Micro (on FB2 board) are alive or not like 
watch dog timer. When BEM has not boot up, TVM try to re-start. We can see chassis
reboot at this case. Check FB2 board has correct power or not.
-
FB2 board
-
CN 5600 12V, 6.5V power and harness to GF1(GF2) Board.
-
F4100, F4102, F5200  conduction.
If power rail has no problem, replace FB2 board.
3-2. Set Reboots
KLV-46/52X300A, 46/52W380A (CH)     3-4
Panel Balancer Error
BALANCER
13
FAN Error (Not Detected. Display Only)
FAN_ERR
9
Temperature Abnormal Detection
TEMP ERR
7
Audio Abnormal Detection
AUD PROT
8
Back Light Error (Panel Inverter)
BACKLITE
6
T-CON Error
T_CON
5
Power Error
POW ERR1
3
Main Power Over Voltage Protection
POW OVP
2
Contents
Display 
(Self Diagnosis mode)
Red LED
Blink
When self diagnosis happens, STANDBY (RED) LED blinks and 
the history can be seen on display by self diagnosis mode.
3-3. SELF DIAGNOSIS
KLV-46/52X300A, 46/52W380A (CH)     3-5
NO
2 Times
YES
See  
3-3-2. POWER OVP
(RED 2 times blink)
RED LED Blinks
NO
3 Times
YES
See  
3-3-3. POWER ERROR
(RED 3 times blink)
NO
5 Times
YES
See  
3-3-4. T-CON ERROR
 (RED 5 times blink)
NO
6 Times
YES
See  
3-3-5. BACK LIGHT ERROR 
(RED 6 times blink)
NO
7 Times
YES
See  
3-3-6 TEMP ERR
(RED 7 times blink)
NO
8 Times
YES
See  
3-3-7 AUDIO ERROR
(RED 8 times blink)
13 Times
YES
3-3-1. Flow Chart_C  
(Standby Indicator)
See  
3-3-9. BALANCER ERROR
(RED 13 times blink)
KLV-46/52X300A, 46/52W380A (CH)     3-6
This indicates POWER Error, Low B error of 12V from GF1(GF2) board. TV Micro
(on AG board) pin150 detects POWER_ERR and shuts down chassis power to Stand-
by status.
TV Micro #150
Normal condition : High  /   Error case : Low
- Check 12V at CN002 #1#2 on AG board. And F200 on AG has 12V or not
- Check GF1(GF2) board.
3-3-3. POWER ERROR (RED 3 Times blink) 
This indicates OVP (Over Voltage Protection) of GF1(GF2) board.
12V line or 6.5Vline on GF1(GF2) board is over-voltage.
TV Micro (on AG board) pin139 detects OVP ERR and shuts down chassis power to
 
Stand-by status.
TV Micro #139
Normal condition : Low  /   Error case : High
Replace GF1(GF2) board.
3-3-2. POWER OVP (RED 2 Times blink) 
Page of 87
Display