DOWNLOAD Sony KLV-40ZX1M Service Manual ↓ Size: 1.19 MB | Pages: 29 in PDF or view online for FREE

Model
KLV-40ZX1M
Pages
29
Size
1.19 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
klv-40zx1m.pdf
Date

Sony KLV-40ZX1M Service Manual ▷ View online

KLV-40ZX1M (UC)     4
SAFETY CHECK-OUT
After correcting the original service problem, perform the
following safety checks before releasing the set to the customer:
1. Check the area of your repair for unsoldered or poorly
soldered connections. Check the entire board surface for
solder splashes and bridges.
2. Check the interboard wiring to ensure that no wires are
“pinched” or touching high-wattage resistors.
3. Check that all control knobs, shields, covers, ground straps,
and mounting hardware have been replaced. Be absolutely
certain that you have replaced all the insulators.
4. Look for unauthorized replacement parts, particularly
transistors, that were installed during a previous repair. Point
them out to the customer and recommend their replacement.
5. Look for parts which, though functioning, show obvious
signs of deterioration. Point them out to the customer and
recommend their replacement.
6. Check the line cords for cracks and abrasion. Recommend
the replacement of any such line cord to the customer.
7. Check the antenna terminals, metal trim, “metallized”
knobs, screws, and all other exposed metal parts for AC
leakage. Check leakage as described below.
Leakage Test
The AC leakage from any exposed metal part to earth ground
and from all exposed metal parts to any exposed metal part
having a return to chassis, must not exceed 0.5 mA (500
microamperes).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or
RCA WT-540A. Follow the manufacturers’ instructions to
use these instructions.
2. A battery-operated AC milliampmeter. The Data Precision
245 digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The “limit”
indication is 0.75 V, so analog meters must have an accurate
low voltage scale.
The Simpson’s 250 and Sanwa SH-63TRD are examples of
passive VOMs that are suitable. Nearly all battery-operated
digital multimeters that have a 2 VAC range are suitable (see
Figure A).
How to Find a Good Earth Ground
A cold-water pipe is a guaranteed earth ground; the cover-plate
retaining screw on most AC outlet boxes is also at earth ground.
If the retaining screw is to be used as your earth ground, verify
that it is at ground by measuring the resistance between it and a
cold-water pipe with an ohmmeter. The reading should be zero
ohms.
If a cold-water pipe is not accessible, connect a 60- to 100-watt
trouble- light (not a neon lamp) between the hot side of the
receptacle and the retaining screw. Try both slots, if necessary,
to locate the hot side on the line; the lamp should light at normal
brilliance if the screw is at ground potential (see Figure B).
To  Exposed Metal
Parts on Set
0.15 
µ
F
Earth Ground
AC
Voltmeter
o
o
(0.75V)
Trouble Light
AC Outlet Box
Ohmmeter
Cold-water Pipe
FigureA. Using an AC voltmeter to check AC leakage.  
Figure B. Checking for earth ground.
KLV-40ZX1M (UC)     5
SELF DIAGNOSIS FUNCTION
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY LED will automatically begin to flash.
The number of times the LED flashes translates to a probable source of the problem.
A definition of the STANDBY LED flash indicators is listed in the instruction manual for the user’s knowledge and reference.
If an error symptom cannot be reproduced, the remote commander can be used to review the failure occurrence data stored in memory to
reveal past problems and how often these problems occur.
DIAGNOSTIC TEST INDICATORS
When an error occurs, the STANDBY LED will flash a set number of times to indicate the possible cause of the problem.
If there is more than one error, the LED will identify the first of the problem areas.
Result for all of the following diagnostic items are displayed on screen.
If the screen displays a “0”, no error has occurred .
Number of times STANDBY
Monitoring Items
LED (Red) flashes
(Screen Display)
Diagnostic Item Description
2 times
Main Power
Abnormal 12V.
3 times
DC Alert
Abnormal 5V.
5 times
Panel Alert
Not use.
6 times
Backlight
Abnormal Inverter.
7 times
Temperature
Abnormal temperature inside unit.
8 times
Audio
Abnormal Audio circuit.
9 times
Fan
Not use.
10 times
Digital FE
Not use.
11 times
Trident
Abnormal BE.
12 times
FRC Ack
Abnormal FRC ACK.
13 times
Backlight Balance
Not use.
14 times
Tcon
Abnormal T-CON.
DISPLAY OF STANDBY LIGHT FLASH COUNT
STOPPING THE STANDBY FLASH
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY LED for flashing.
STANDBY LED
2 times
4 times
5 times
LED ON  0.3 sec.
LED OFF 0.3 sec.
LED OFF
2 sec. 
[ FLASH COUNT ]
Note: One flash counts is not self-diagnostic.
KLV-40ZX1M (UC)     6
SELF-DIAGNOSTIC SCREEN DISPLAY
For errors with symptoms such as “power sometimes shuts off” or “screen sometimes goes out” that cannot be confirmed, it is possible to
bring up past occurrences of failure for confirmation on the screen:
[To Bring Up Screen Test]
In standby mode, press buttons on the remote commander sequentially in rapid succession as shown below:
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen
After you have completed the repairs, clear the result display to “0”.
Clearing the result display
To clear the result display to “0”, press button on the remote commander sequentially as shown below when the diagnostic screen is being
displayed.
Quitting Self-diagnostic screen
To quit the entire self-diagnostic screen, turn off the power switch on the remote commander or the main unit.
5
* : Note that this differs from entering the service mode (volume +)
( Number button )
( Volume )
INFO
VOL -
POWER
Total Operation Time
Boot Count
Panel Operation Time
Power Off-On Count
0
0
0
0
[ SCREEN DISPLAY ]
KLV-40ZX1M (UC)     7
TABLE OF CONTENTS
SPECIFICATIONS .................................................... 2
SAFETY CHECK-OUT ............................................. 4
SELF DIAGNOSIS FUNCTION ................................ 5
TABLE OF CONTENTS ........................................... 7
1. DISASSEMBLY ............................................... 1-1
1-1.
MONITOR .............................................................. 1-1
1-1-1.
TERMINAL COVER REMOVAL ................. 1-1
1-1-2.
REAR COVER REMOVAL ............................ 1-1
1-1-3.
IF1, H1L, H3L AND H4L BOARDS
REMOVAL ...................................................... 1-2
1-1-4.
B AND HSL BOARDS, AC INLET
REMOVAL ...................................................... 1-2
1-1-5.
GS1 AND LD1 BOARDS REMOVAL .......... 1-3
1-2.
STAND ................................................................... 1-4
1-2-1.
BASE STAND REMOVAL ............................ 1-4
1-2-2.
ARM STAND REMOVAL ............................. 1-4
2. TROUBLESHOOTING .................................... 2-1
2-1.
FLOW CHART ...................................................... 2-1
2-2.
NO POWER ........................................................... 2-2
2-3.
STANDBY LED BLINK ....................................... 2-2
1)
2 times Blinkings ............................................ 2-2
2)
3 times Blinkings ............................................ 2-2
3)
6 times Blinkings ............................................ 2-3
4)
7 times Blinkings ............................................ 2-3
5)
8 times Blinkings ............................................ 2-3
6)
11 times Blinkings .......................................... 2-4
7)
12 times Blinkings .......................................... 2-4
8)
14 times Blinkings .......................................... 2-4
2-4.
NO PICTURE ......................................................... 2-5
2-5.
NO SOUND ............................................................ 2-5
2-6.
THE KEY CANNOT BE OPERATION ............... 2-6
1)
Malfunctioning the key of the unit ................. 2-6
2)
Malfunctioning the key of the IR remote
controller ......................................................... 2-6
3. ADJUSTMENT ................................................ 3-1
3-1.
WHITE BALANCE ADJUSTMENT .................... 3-1
3-2.
UPDATING SOFTWARE AFTER REPLACING
THE B BOARD OR PANEL MODULE ............... 3-1
3-3.
HOW TO ENTERING SERVICE MODE ............ 3-1
4. DIAGRAMS ..................................................... 4-1
4-1.
BLOCK DIAGRAM .............................................. 4-1
4-2.
CIRCUIT BOARDS LOCATION ......................... 4-2
5. EXPLODED VIEWS ........................................ 5-1
5-1.
MONITOR .............................................................. 5-2
5-1-1.
REAR COVER ................................................. 5-2
5-1-2.
CHASSIS-1 ...................................................... 5-3
5-1-3.
CHASSIS-2 ...................................................... 5-4
5-1-4.
CONNECTOR ASSY ...................................... 5-5
5-2.
STAND ................................................................... 5-6
5-3.
PACKING MATERIALS ...................................... 5-7
Page of 29
Display

Sony KLV-40ZX1M Service Manual ▷ Download

  • DOWNLOAD Sony KLV-40ZX1M Service Manual ↓ Size: 1.19 MB | Pages: 29 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sony KLV-40ZX1M in PDF for free, which will help you to disassemble, recover, fix and repair Sony KLV-40ZX1M TV. Information contained in Sony KLV-40ZX1M Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.