DOWNLOAD Sony KLV-40V510A / KLV-46V510A (serv.man2) Service Manual ↓ Size: 19.59 MB | Pages: 93 in PDF or view online for FREE

Model
KLV-40V510A KLV-46V510A (serv.man2)
Pages
93
Size
19.59 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
klv-40v510a-klv-46v510a-sm2.pdf
Date

Sony KLV-40V510A / KLV-46V510A (serv.man2) Service Manual ▷ View online

5
KLV-40V510A/46V510A/52V510A
KLV-40V510A/46V510A/52V510A
Television system
NTSC 3.58/PAL-M/PAL-N
Trinorma
Channel coverage
 VHF: 
2-13
 UHF: 
14-69
 CATV: 
1-125
Antenna
75-ohm external terminal for RF inputs
Panel System
LCD (Liquid Crystal Display) Panel
Display Resolution (horizontal x vertical)
1,920 dots (horizontal) x 1,080 lines (vertical)
Screen Size (measured diagonally)
~ 40 in/101.6 cm (KLV-40V510A Only)
~ 46 in/116.8 cm (KLV-46V510A Only)
~ 52 in/132.2 cm (KLV-52V510A Only)
Supplied Accessories
Remote Commander RM-YD028
Two Size AA (R6) Batteries
Cable Holder (1 attached to the TV)
Operating Instructions
Quick Setup Guide
Safety and Regulatory Booklet
Attaching the Table-Top Stand Flyer
Screws (4) (KLV-40V510A/46V510A Only)
Optional Accessories
Connecting Cables
Support Belt Kit
Wall-Mount Bracket
 SU-WL500
Speaker Output
Speaker/Full Range (2)
(mm)
Dimensions (W x H x D)
with stand
(mm)
987 x 684 x 271 mm
1,123 x 772 x 323 mm
1,262 x 871 x 362 mm
without stand
(mm)
987 x 638 x 93 mm
1,123 x 725 x 96 mm
1,262 x 823 x 115 mm
wall-mount hole pattern (mm)
Mass
with stand
kg
18.6 kg
25.5 kg
34.6 kg
without stand
kg
16.9
22.6 kg
30.0 kg
All measurements are approximations.
wall-mount screw size (mm)
KLV-46V510A
KLV-40V510A
M6 x 8-12 mm
300 x 300
KLV-52V510A
10 W+ 10 W
35 X 175
6
KLV-40V510A/46V510A/52V510A
KLV-40V510A/46V510A/52V510A
WARNINGS AND CAUTIONS - ENGLISH
CAUTION
These servicing instructions are for use by qualifi ed service personnel only. To reduce the risk of electric shock, do not perform any servicing other 
than that contained in the operating instructions unless you are qualifi ed to do so.z
CARRYING THE TV
WARNING!!
An isolation transformer should be used during any service to avoid possible shock hazard, because of live chassis. The chassis of this receiver is 
directly connected to the ac power line.
!
 SAFETY-RELATED COMPONENT WARNING!!
Components identifi ed by shading and ! mark on the schematic diagrams, exploded views, and in the parts list are critical for safe operation. Replace 
these components with Sony parts whose part numbers appear as shown in this manual or in supplements published by Sony. Circuit adjustments that 
are critical for safe operation are identifi ed in this manual. Follow these procedures whenever critical components are replaced or improper operation is 
suspected. 
Be sure to consider the following while setting up your TV:
• Carry the TV with an adequate number of people; larger size TVs require two or more people.
• Correct hand placement while carrying the TV is very important for safety and to avoid 
damages.
7
KLV-40V510A/46V510A/52V510A
KLV-40V510A/46V510A/52V510A
SAFETY-RELATED COMPONENT WARNING
There are critical components used in LCD color TVs that are important for safety. These components are identifi ed with shading and 
!
 
mark on the schematic diagrams and the electrical parts list. It is essential that these critical parts be replaced only with the part number 
specifi ed in the electrical parts list to prevent electric shock, fi re, or other hazard. 
NOTE: Do not modify the original design without obtaining written permission from the manufacturer or you will void the original parts and 
            labor guarantee. 
USE CAUTION WHEN HANDLING THE LCD PANEL
When repairing the LCD panel, be sure you are grounded by using a wrist band.
When installing the LCD panel on a wall, the LCD panel must be secured using the 4 mounting holes on the rear cover. 
To avoid damaging the LCD panel:
 do not press on the panel or frame edge to avoid the risk of electric shock.
  do not scratch or press on the panel with any sharp objects.
  do not leave the module in high temperatures or in areas of high humidity for an extended period of time.
  do not expose the LCD panel to direct sunlight.
  avoid contact with water. It may cause a short circuit within the module. 
  disconnect the AC adapter when replacing the backlight (CCFL) or inverter circuit. 
(High voltage occurs at the inverter circuit at 650Vrms.) 
  always clean the LCD panel with a soft cloth material.
  use care when handling the wires or connectors of the inverter circuit. Damaging the wires may cause a short. 
  protect the panel from ESD to avoid damaging the electronic circuit (C-MOS). 
LEAKAGE CURRENT HOT CHECK CIRCUIT
8
KLV-40V510A/46V510A/52V510A
KLV-40V510A/46V510A/52V510A
The circuit boards used in these models have been processed using
Lead Free Solder. The boards are identified by the LF logo located
close to the board designation e.g. H1 etc [ see example ]. The
servicing of these boards requires special precautions to be taken as
outlined below.
example 1
It is strongly recommended to use Lead Free Solder material in order to guarantee optimal quality of new solder joints. 
Lead Free Solder is available under the following part numbers :
Due to the higher melting point of Lead Free Solder the soldering iron tip temperature needs to be set to 370 degrees centigrade. 
This requires soldering equipment capable of accurate temperature control coupled with a good heat recovery characteristics.
For more information on the use of Lead Free Solder, please refer to  http://www.sony-training.com
r
e
b
m
u
n
t
r
a
P
r
e
t
e
m
a
i
D
s
k
r
a
m
e
R
9
1
-
5
0
0
-
0
4
6
-
7
m
m
3
.
0
g
K
5
2
.
0
0
2
-
5
0
0
-
0
4
6
-
7
m
m
4
.
0
g
K
0
5
.
0
1
2
-
5
0
0
-
0
4
6
-
7
m
m
5
.
0
g
K
0
5
.
0
2
2
-
5
0
0
-
0
4
6
-
7
m
m
6
.
0
g
K
5
2
.
0
3
2
-
5
0
0
-
0
4
6
-
7
m
m
8
.
0
g
K
0
0
.
1
4
2
-
5
0
0
-
0
4
6
-
7
m
m
0
.
1
g
K
0
0
.
1
5
2
-
5
0
0
-
0
4
6
-
7
m
m
2
.
1
g
K
0
0
.
1
6
2
-
5
0
0
-
0
4
6
-
7
m
m
6
.
1
g
K
0
0
.
1
Page of 93
Display

Click on the first or last page to see other KLV-40V510A / KLV-46V510A (serv.man2) service manuals if exist.