DOWNLOAD Sony KLV-40V440A / KLV-46V440A / KLV-52V440A Service Manual ↓ Size: 8.45 MB | Pages: 45 in PDF or view online for FREE

Model
KLV-40V440A KLV-46V440A KLV-52V440A
Pages
45
Size
8.45 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
klv-40v440a-klv-46v440a-klv-52v440a.pdf
Date

Sony KLV-40V440A / KLV-46V440A / KLV-52V440A Service Manual ▷ View online

KLV-40/46/52V440A (CH)     2
SPECIFICATIONS
Panel System
TV System
Colour System
Channel Coverage
Sound Output
Input/Output jacks
Antenna
S          (S VIDEO)         1
         (VIDEO)        1, 2, 3
         (AUDIO)        1, 2, 3
HD/DVD         (HD/DVD
In)        1/        2
HDMI          (HDMI IN) 1, 2, 3
         (VIDEO)
         (AUDIO)
PC         (PC IN)          (RGB)
         (Headphone)
DMPORT
Power and others
Power Requirements
Screen Size
Display Resolution
Power Consumption
Standby Power Consumption*
Dimensions** with stand
(w 
× h × d)      (mm)
                     
without stand
                      
(mm)
Mass**           with stand (kg)
                      
without stand
                        (kg)
LCD (Liquid Crystal Display) Panel
B/G, I, D/K, M
PAL, PAL60, SECAM, NTSC 3.58, NTSC 4.43 (only Video In)
B/G: VHF: E2 to E12/ UHF: E21 to E69/ CATV: S01 to S03, S1 to S41
I:      UHF: B21 to B69/ CATV: S01 to S03, S1 to S41
D/K: VHF: C1 to C12, R1 to R12/ UHF: C13 to C57, R21 to R60/ CATV: S01 to S03, S1 to S41, Z1 to Z39
M:    VHF: A2 to A13/ UHF: A14 to A79/ CATV: A-8 to A-2, A to W+4, W+6 to W+84
10 W + 10 W
75 ohm external terminal for VHF/UHF
S video input (4-pin mini DIN)
Video input (phono jack)
Audio input (phono jacks): 500 mVrms, Impedance: 47 kilohms
Supported formats: 1080p, 1080i, 720p, 576p, 576i, 480p, 480i
Y: 1 Vp-p, 75 ohms, 0.3V negative sync/P
B
/C
B
: 0.7 Vp-p, 75 ohms/
P
R
/C
R
: 0.7 Vp-p, 75 ohms
Video: 1080/24p, 1080p, 1080i, 720p, 576p, 576i, 480p, 480i
Audio: Two channel linear PCM
32, 44.1 and 48 kHz, 16, 20 and 24 bits
Analogue audio input (minijack) (HDMI            (HDMI IN) 3 only)
Video output (phono jack)      
Audio output (phono jacks)
PC Input (D-sub 15-pin) 
G: 0.7 Vp-p, 75 ohms, non Sync on Green/B: 0.7 Vp-p, 75 ohms/
R: 0.7 Vp-p, 75 ohms/HD: 1-5 Vp-p/VD: 1-5 Vp-p
PC audio input (minijack)
Headphones jack
DIGITAL MEDIA PORT 
220 V AC, 50 Hz
132 cm (52 inches)  
117 cm (46 inches)
102 cm (40 inches)
1,920 dots (horizontal) 
× 1,080 lines (vertical)
280 W
270 W
220 W
0.3 W
1,262 
× 871 × 347 
1,120 
× 782 × 307
986 
× 684 × 279
1,262 
× 829 × 119 
1,120 
× 742 × 115 
986 
× 646 × 110
39
30
23
33
26
19
5
°C - 35°C
20% - 80%
86 kPa - 106 kPa
Model name
KLV-52V440A
KLV-46V440A
KLV-40V440A
System
*  Specified standby power is reached after the TV finishes necessary internal processes.
**  The values of dimensions and mass are approximate.
KLV-40/46/52V440A (CH)     3
Design and specifications are subject to change without notice.
PC Input Signal Reference Chart
Model name
KLV-52V440A
KLV-46V440A
KLV-40V440A
Signals
Horizontal (Pixel)
Vertical (Line)
Standard
Horizontal
frequency
(kHz)
Vertical
frequency (Hz)
VGA 
640 480 
31.5 
60 
VGA
640 480 
37.5 
75 
VESA
720 400 
31.5 
70 
VGA-T
SVGA 
800 600 
37.9 
60 
VESA 
Guidelines
800 600 
46.9 
75 
VESA
XGA 
1024 768 
48.4 
60 
VESA 
Guidelines
1024 768 
56.5 
70 
VESA
1024 768 
60 
75 
VESA
WXGA 
1280 768 
47.4 
60 
VESA
1280 768 
47.8 
60 
VESA
1360 768 
47.7 
60 
VESA
  This TV’s PC input does not support Sync on Green or Composite Sync.
  This TV’s PC input does not support interlaced signals.
  If input signal is not shown in above chart, then this signal may not be displayed properly or cannot be displayed according to
your settings.
  For the best picture quality, it is recommended to use the signals (boldfaced) in the above chart with a 60 Hz vertical frequency
from a personal computer. In plug and play, signals with a 60 Hz vertical frequency will be selected automatically.
KLV-40/46/52V440A (CH)     4
CAUTION
These servicing instructions are for use by qualified service
personnel only.
To reduce the risk of electric shock, do not perform any servicing
other than that contained in the operating instructions unless you
are qualified to do so.
WARNING!!
An isolation transformer should be used during any service to
avoid possible shock hazard, because of live chassis.
The chassis of this receiver is directly connected to the ac power
line.
!
 
SAFETY-RELATED COMPONENT
WARNING!!
Replace all components with Sony parts whose part numbers
appear as shown in this manual or in supplements
published by Sony.
WARNINGS AND CAUTIONS
SAFETY-RELATED COMPONENT
WARNING
It is essential that all critical parts be replaced only with the part
number specified in the electrical parts list to prevent electric
shock, fire, or other hazard.
NOTE: Do  not modify the original design without obtaining
written permission from the manufacturer or you will
void the original parts and labor guarantee.
USE CAUTION WHEN HANDLING THE LCD PANEL
When repairing the LCD panel, be sure you are grounded by
using a wrist band.
When repairing the LCD panel on the wall, the LCD panel must
be secured using the 4 mounting holes on the rear cover.
1) Do not press on the panel or frame edge to avoid the risk of
electric shock.
2) Do not scratch or press on the panel with any sharp objects.
3) Do not leave the module in high temperatures or in areas of
high humidity for an extended period of time.
4) Do not expose the LCD panel to direct sunlight.
5) Avoid contact with water. It may cause a short circuit within
the module.
6) Disconnect the AC power when replacing the backlight (CCFL)
or inverter circuit.
(High voltage occurs at the inverter circuit at 650Vrms.)
7) Always clean the LCD panel with a soft cloth material.
8) Use care when handling the wires or connectors of the inverter
circuit. Damaging the wires may cause a short.
9) Protect the panel from ESD to avoid damaging the electronic
circuit (C-MOS).
KLV-40/46/52V440A (CH)     5
SAFETY CHECK-OUT
After correcting the original service problem, perform the
following safety checks before releasing the set to the customer:
1. Check the area of your repair for unsoldered or poorly
soldered connections. Check the entire board surface for
solder splashes and bridges.
2. Check the interboard wiring to ensure that no wires are
“pinched” or touching high-wattage resistors.
3. Check that all control knobs, shields, covers, ground straps,
and mounting hardware have been replaced. Be absolutely
certain that you have replaced all the insulators.
4. Look for unauthorized replacement parts, particularly
transistors, that were installed during a previous repair. Point
them out to the customer and recommend their replacement.
5. Look for parts which, though functioning, show obvious
signs of deterioration. Point them out to the customer and
recommend their replacement.
6. Check the line cords for cracks and abrasion. Recommend
the replacement of any such line cord to the customer.
7. Check the antenna terminals, metal trim, “metallized”
knobs, screws, and all other exposed metal parts for AC
leakage. Check leakage as described below.
Leakage Test
The AC leakage from any exposed metal part to earth ground
and from all exposed metal parts to any exposed metal part
having a return to chassis, must not exceed 0.5 mA (500
microamperes).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or
RCA WT-540A. Follow the manufacturers’ instructions to
use these instructions.
2. A battery-operated AC milliampmeter. The Data Precision
245 digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The “limit”
indication is 0.75 V, so analog meters must have an accurate
low voltage scale.
The Simpson’s 250 and Sanwa SH-63TRD are examples of
passive VOMs that are suitable. Nearly all battery-operated
digital multimeters that have a 2 VAC range are suitable (see
Figure A).
How to Find a Good Earth Ground
A cold-water pipe is a guaranteed earth ground; the cover-plate
retaining screw on most AC outlet boxes is also at earth ground.
If the retaining screw is to be used as your earth ground, verify
that it is at ground by measuring the resistance between it and a
cold-water pipe with an ohmmeter. The reading should be zero
ohms.
If a cold-water pipe is not accessible, connect a 60- to 100-watt
trouble- light (not a neon lamp) between the hot side of the
receptacle and the retaining screw. Try both slots, if necessary,
to locate the hot side on the line; the lamp should light at normal
brilliance if the screw is at ground potential (see Figure B).
To  Exposed Metal
Parts on Set
0.15 
µ
F
Earth Ground
AC
Voltmeter
o
o
(0.75V)
Trouble Light
AC Outlet Box
Ohmmeter
Cold-water Pipe
FigureA. Using an AC voltmeter to check AC leakage.  
Figure B. Checking for earth ground.
Page of 45
Display

Sony KLV-40V440A / KLV-46V440A / KLV-52V440A Service Manual ▷ Download

  • DOWNLOAD Sony KLV-40V440A / KLV-46V440A / KLV-52V440A Service Manual ↓ Size: 8.45 MB | Pages: 45 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sony KLV-40V440A / KLV-46V440A / KLV-52V440A in PDF for free, which will help you to disassemble, recover, fix and repair Sony KLV-40V440A / KLV-46V440A / KLV-52V440A TV. Information contained in Sony KLV-40V440A / KLV-46V440A / KLV-52V440A Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.