Sony KLV-32V400A / KLV-32V400B Service Manual ▷ View online
– 16 –
KLV-32V400A, V400B
RM-GA011
4-1-11. Dress Speaker Wire(L) with LCD tape(2X).
4-1-12. Dress Connector Assy 14P+20P with
LCD tape.
4-1-13. Install AC Cord Holder on AC Power Cord.
For Non-CISPR model only
4-1-14. Install AC Cord Holder on AC Power Cord.
For CISPR model only
Ferrite Core
Cable tie
Note : Make sure tighten cable tie and cut excess part.
Datum
Datum
Caution : Pull wire until cannot reach
sharp edge area when apply LCD tape.
sharp edge area when apply LCD tape.
Caution : Pull wire until cannot reach
sharp edge area when apply LCD tape.
sharp edge area when apply LCD tape.
170mm
170mm
70mm
LCD tape
Speaker Wire
LCD tape
Connector assy 14P+20P
AC Cord holder
AC Power Cord
AC Cord holder
AC Power Cord
– 17 –
KLV-32V400A, V400B
RM-GA011
4-1-15. i) Screw Connector Assy 1P on BG1 & Main Bracket.
ii) Put Connector Assy 1P underneath Speaker Wire.
~90
Connector Assy 1P
Speaker Wire
– 18 –
KLV-32V400A, V400B
RM-GA011
5-1. Accessing Diagnostic Menu
1.
While TV set on standby, press the following sequence on
the remote commander (RM-GA011).
the remote commander (RM-GA011).
2.
The following menu will appear on the screen:
3.
To reset, select ‘RESET’ using remote commander and
press
press
to execute RESET.
4.
To quit the diagnostic menu, turn off and on the TV set.
5-2. Aging
1.
While TV set on standby, press the following sequence on
the remote commander (RM-GA011).
the remote commander (RM-GA011).
2.
The following menu will appear on the screen.
On screen
display
Channel 5
Volume (-)
POWER
ERROR
DC_DET
DC_ALERT1
DC_ALERT2
DC_ALERT3
BACKLIGHT
INTERNAL TEMP ERROR
AUDIO ERROR
NVM ERROR
IIC ERROR
BALANCER ERROR
HDMI ERROR
0
0
0
0
0
0
0
0
0
0
0
RESET
0
3.
Press
V/v to select ‘Service’.
4.
Press
B/b or to view ‘Service’ category items.
Press
V/v to selec /‘P ATTERN’.
5.
Then press
B/b then V/v to select ‘WHITE PATTERN’
and
.
6.
The aging Condition is as the following:
a) Supply voltage
a) Supply voltage
: Rating
b) Time
: 20 minutes or over
c) Ambient Temp
: 22~28 degrees
SECTION 5
SERVICE ADJUSTMENTS
Figure 1
Figure 4
Figure 2
Figure 3
On screen
display
Channel 5
Volume (+)
POWER
Service Menu
Status
W/B
Service
Service Menu
TEST RESET
PATTERN
PRODUCTION
APC
OVER MODULATION
OPTIONS
AUTOSET FACTORY
SERIAL NUMBER EDIT
ETI1 CLEAR
No Signal Mute
Cancel
WHITE PATTERN
11111111
Normal
Off
DEFAULT
Off
Service
OPT 1
Cancel
Figure 5
Service Menu
Status
W/B
Service
Service Menu
Service
PATTERN
Off
WHITE PATTERN
RED PATTERN
GREEN PATTERN
BLUE PATTERN
Figure 6
– 19 –
KLV-32V400A, V400B
RM-GA011
5-3. Resetting the User Menu - Factory Reset
Note: THE TEST RESET option resets all the customer
adjustable data back to factory defaults.
adjustable data back to factory defaults.
1.
While TV set on standby, press the following sequence on
the remote commander (RM-GA011).
the remote commander (RM-GA011).
2.
The following menu will appear on the screen:
3.
Press
V/v to select ‘Service’.
4.
Then press
B/b or to view ‘Service’ category items.
Next select ‘TEST RESET’ by pressing
V/v .
5.
Finally press
B/b or then V/v to select ‘OK’ and confirm
selection by pressing
.
5-4. White Balance Adjustment
Note: The white balance need to be adjusted when BG1 board
and Panel is replaced.
and Panel is replaced.
1.
While TV set on standby, press the following sequence on
the remote commander (RM-GA011).
the remote commander (RM-GA011).
2.
The following menu will appear on the screen:
3.
Press
B/b or to view ‘W/B’.
4.
Then press
B/b or to view ‘W/B’ category items.
5.
Press
V/v to select ‘INITIALIZE’.
6
Then press
B/b or then V/v to select ‘INIT START’ and
execute selection by pressing
.
7.
W/B need to be adjusted for all LEVEL (0~4).
Figure 14
Service Menu
W/B
INITIALIZE
LEVEL
R_DRIVE
G_DRIVE
INIT START
0
0
0
B_DRIVE
0
Cancel
COLOR_SAVE
Service Menu
Status
W/B
Service
Figure 15
Figure 7
Figure 8
Service Menu
Status
W/B
Service
On screen
display
Channel 5
Volume (-)
POWER
Service Menu
Service
TEST RESET
PATTERN
PRODUCTION
APC
OVER MODULATION
OPTIONS
AUTOSET FACTORY
SERIAL NUMBER EDIT
ETI1 CLEAR
No Signal Mute
Cancel
Off
11111111
Normal
Off
OPT1
DEFAULT
Off
Cancel
Figure 12
Service Menu
Status
W/B
Service
Figure 9
Figure 10
Figure 13
Service Menu
Status
W/B
Service
On screen
display
Channel 5
Volume (-)
POWER
Service Menu
Service
TEST RESET
OK
Cancel
Figure 11
Service Menu
W/B
INITIALIZE
INIT START
INIT END
Figure 16
Click on the first or last page to see other KLV-32V400A / KLV-32V400B service manuals if exist.