DOWNLOAD Sony KLV-32S510A / KLV-40S510A / KLV-46S510A / KLV-52S510A Service Manual ↓ Size: 19.93 MB | Pages: 97 in PDF or view online for FREE

Model
KLV-32S510A KLV-40S510A KLV-46S510A KLV-52S510A
Pages
97
Size
19.93 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
klv-32s510a-klv-40s510a-klv-46s510a-klv-52s510a.pdf
Date

Sony KLV-32S510A / KLV-40S510A / KLV-46S510A / KLV-52S510A Service Manual ▷ View online

5
KLV-32S510A/40S510A/46S510A/52S510A
KLV-32S510A/40S510A/46S510A/52S510A
Speaker Output
Speaker/Full Range (2)
mm
in
Dimensions (W x H x D)
with stand
mm
798 x 583 x 227 mm
987 x 683 x 271 mm
1,123 x 770 x 323 mm
1,262 x 869 x 362 mm
in
31
1/2
 x 23 x 9 in
38
7/8
 x 27 x 10
3/4
 in
44
1/4
 x 30
3/8
 x 12
3/4
 in
49
3/4
 x 34
1/4
 x 14
3/8
 in
without stand
mm
798 x 536 x 89 mm
987 x 636 x 93 mm
1,123 x 723 x 96 mm
1,262 x 822 x 115 mm
in
31
1/2
x 21
1/8
 x 3
5/8
 in
38
7/8
 x 25
1/8
 x 3
3/4
 in
44
1/4
 x 29
1/2
 x 3
7/8
 in
49
3/4
 x 32
3/8
 x 4
5/8
 in
wall-mount hole pattern (mm)
200 x 200
Mass
with stand
kg
13.1 kg
18.5 kg
25.5 kg
34.5 kg
lbs
28.9 lbs
40.8 lbs
56.2 lbs
76.0 lbs
without stand
kg
11.9 kg
16.8 kg
22.6 kg
29.9 kg
lbs
26.3 lbs
37.1 lbs
49.8 lbs
65.9 lbs
All measurements are approximations.
1
7/16
 x 7
wall-mount screw size (mm)
KLV-46S510A
KLV-40S510A
KLV-32S510A
300 x 300
M6 x 8-12 mm
KLV-52S510A
10 W+ 10 W
35 X 175
Television system
NTSC  
American 
TV 
Standard
ATSC (8VSB terrestrial)  ATSC compliant 8VSB
QAM on cable 
ANSI/SCTE 07 2000
Channel coverage
Analog
 2-69 
Terrestrial
 1-135 
Cable
Digital
 2-69 
Terrestrial
 1-135 
Cable
Antenna
75-ohm external terminal for RF inputs
Panel System
LCD (Liquid Crystal Display) Panel
Display Resolution (horizontal x vertical)
1,920 dots x 1,080 lines
Screen Size (measured diagonally)
~ 31.5” (KLV-32S510A Only)
~ 40” (KLV-40S510A Only)
~ 46” (KLV-46S510A Only)
~ 52” (KLV-52S510A Only)
Supplied Accessories
Remote Commander RM-YD028
Two Size AA (R6) Batteries
Cable Holder (1 attached to the TV)
Operating Instructions
Quick Setup Guide
Warranty Card
Safety and Regulatory Booklet
Attaching the Table-Top Stand Flyer
Screws (4) (KLV-32S510A/40S510A/46S510A Only)
Optional Accessories
Connecting Cables
Wall-Mount Bracket
 SU-WL500
6
KLV-32S510A/40S510A/46S510A/52S510A
KLV-32S510A/40S510A/46S510A/52S510A
WARNINGS AND CAUTIONS - ENGLISH
CAUTION
These servicing instructions are for use by qualifi ed service personnel only. To reduce the risk of electric shock, do not perform any servicing other 
than that contained in the operating instructions unless you are qualifi ed to do so.
CARRYING THE TV
Be sure to consider the following while setting up your TV:
• Carry the TV with an adequate number of people; larger size TVs require two or more people.
• Correct hand placement while carrying the TV is very important for safety and to avoid 
damages.
• Ensure your TV has adequate ventilation if it is installed against a wall or in an enclosed area.
• For best picture quality, do not expose the screen to direct illumination or sunlight.
• Avoid installing the TV in a room with reflective wall and floor materials.
• Avoid moving the TV from a cold area to a warm area. Sudden room temperature changes may 
cause moisture condensation. This may cause the TV to show poor picture and/or poor color. 
Should this occur, allow moisture to evaporate completely before powering the TV on.
WARNING!!
An isolation transformer should be used during any service to avoid possible shock hazard, because of live chassis. The chassis of this receiver is 
directly connected to the ac power line.
!
 SAFETY-RELATED COMPONENT WARNING!!
Components identifi ed by shading and ! mark on the schematic diagrams, exploded views, and in the parts list are critical for safe operation. Replace 
these components with Sony parts whose part numbers appear as shown in this manual or in supplements published by Sony. Circuit adjustments that 
are critical for safe operation are identifi ed in this manual. Follow these procedures whenever critical components are replaced or improper operation is 
suspected. 
7
KLV-32S510A/40S510A/46S510A/52S510A
KLV-32S510A/40S510A/46S510A/52S510A
SAFETY-RELATED COMPONENT WARNING
There are critical components used in LCD color TVs that are important for safety. These components are identifi ed with shading and 
!
 
mark on the schematic diagrams and the electrical parts list. It is essential that these critical parts be replaced only with the part number 
specifi ed in the electrical parts list to prevent electric shock, fi re, or other hazard. 
NOTE: Do not modify the original design without obtaining written permission from the manufacturer or you will void the original parts and 
            labor guarantee. 
USE CAUTION WHEN HANDLING THE LCD PANEL
When repairing the LCD panel, be sure you are grounded by using a wrist band.
When installing the LCD panel on a wall, the LCD panel must be secured using the 4 mounting holes on the rear cover. 
To avoid damaging the LCD panel:
 do not press on the panel or frame edge to avoid the risk of electric shock.
  do not scratch or press on the panel with any sharp objects.
  do not leave the module in high temperatures or in areas of high humidity for an extended period of time.
  do not expose the LCD panel to direct sunlight.
  avoid contact with water. It may cause a short circuit within the module. 
  disconnect the AC adapter when replacing the backlight (CCFL) or inverter circuit. 
(High voltage occurs at the inverter circuit at 650Vrms.) 
  always clean the LCD panel with a soft cloth material.
  use care when handling the wires or connectors of the inverter circuit. Damaging the wires may cause a short. 
  protect the panel from ESD to avoid damaging the electronic circuit (C-MOS). 
LEAKAGE CURRENT HOT CHECK CIRCUIT
8
KLV-32S510A/40S510A/46S510A/52S510A
KLV-32S510A/40S510A/46S510A/52S510A
The circuit boards used in these models have been processed using
Lead Free Solder. The boards are identified by the LF logo located
close to the board designation e.g. H1 etc [ see example ]. The
servicing of these boards requires special precautions to be taken as
outlined below.
example 1
It is strongly recommended to use Lead Free Solder material in order to guarantee optimal quality of new solder joints. 
Lead Free Solder is available under the following part numbers :
Due to the higher melting point of Lead Free Solder the soldering iron tip temperature needs to be set to 370 degrees centigrade. 
This requires soldering equipment capable of accurate temperature control coupled with a good heat recovery characteristics.
For more information on the use of Lead Free Solder, please refer to  http://www.sony-training.com
r
e
b
m
u
n
t
r
a
P
r
e
t
e
m
a
i
D
s
k
r
a
m
e
R
9
1
-
5
0
0
-
0
4
6
-
7
m
m
3
.
0
g
K
5
2
.
0
0
2
-
5
0
0
-
0
4
6
-
7
m
m
4
.
0
g
K
0
5
.
0
1
2
-
5
0
0
-
0
4
6
-
7
m
m
5
.
0
g
K
0
5
.
0
2
2
-
5
0
0
-
0
4
6
-
7
m
m
6
.
0
g
K
5
2
.
0
3
2
-
5
0
0
-
0
4
6
-
7
m
m
8
.
0
g
K
0
0
.
1
4
2
-
5
0
0
-
0
4
6
-
7
m
m
0
.
1
g
K
0
0
.
1
5
2
-
5
0
0
-
0
4
6
-
7
m
m
2
.
1
g
K
0
0
.
1
6
2
-
5
0
0
-
0
4
6
-
7
m
m
6
.
1
g
K
0
0
.
1
Page of 97
Display

Click on the first or last page to see other KLV-32S510A / KLV-40S510A / KLV-46S510A / KLV-52S510A service manuals if exist.