KLV-32FA40A/37FA40A
KLV-32FA40A/37FA40A
SELF-DIAGNOSTIC FUNCTION
Self Diagnosis
Supported model
The units in this manual contain a self-diagnostic function. If an error occurs, the TIMER/PIC OFF LED indicator will automatically begin to fl ash. The 
number of times the LED fl ashes translates to a probable source of the problem. A defi nition of the TIMER/PIC OFF LED fl ash indicators is listed in the 
instruction manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review 
the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
1. Diagnostic Test Indicators
When an error occurs, the TIMER/PIC OFF LED indicator will fl ash a set number of times to indicate the possible cause of the problem. If there is more 
than one error, the indicator will identify the fi rst of the problem areas.
Control Buttons
Description of LED Indictors
LED
LED Type
Description
(IR) Infrared Receiver
None
Receives IR signals from the Remote Control
POWER LED
Green LED
* Light is green when the TV set is on
STANDBY LED
Red LED
* Light is red when the TV set is in standby mode.
* Blinks red when indicating the TV may need servicing
* Light is green when the Picture is Off
* Light is (orange) amber when the timer is set.
TIMER/PIC OFF
LED
Amber/Green
Display of TIMER/PIC OFF LED Flash Count
2 times
5 times
LED ON 0.3 sec.
LED OFF 0.3 sec.
LED OFF
3 sec.
11
KLV-32FA40A/37FA40A
KLV-32FA40A/37FA40A
Viewing the Self Check Diagnostic List
1.  TV must be in standby mode. (Power off).
2.  Press the following buttons on the Remote Commander within a second of each other: 
 
DISPLAY   
Channel 
5   
Volume 
-  
  TV POWER .
 
The Self Check list displays. 
          
  This differs from accessing Service Adjustments.
Results for all of the following diagnostic items are displayed on screen.  No error has occurred if the screen displays a “0”
TV
DC_DET
0
DC_ALERT1
0
DC_ALERT2
0
DC_ALERT3
0
BACKLIGHT
0
TEMPERATURE
0
AUDIO
0
DFE
0
B-ENGINE
0
HFR
0
Failure LED Displays
MONITORING ITEMS
NUMBER OF STANDBY LED
(RED) BLINKING TIMES
Main power supply voltage error
2
DC_ALERT 1
3
DC_ALERT 2
4
DC_ALERT 3
5
Backlight error
6
Internal temperature error
7
Audio error
8
Fan error (HFR model only)
9
Digital FE error
10
Trident error
11
*Each of the above blinking is repeated every 2 seconds
LED Displays during Aging
Condition
LED Displays
When AGING_TIMER > 0
Green (0.5 Sec) 
t Off (0.5 sec) t Green (0.5 sec) t Off (0.5 sec)
When AGING_TIMER = 0
Green (3.0 sec) 
t Off (3.0 sec) t Green (3.0 sec) t Off (3.0 sec)
Clearing the Self Check Diagnostic List
1.  In Service Mode, turn the TV off, then on.
12
KLV-32FA40A/37FA40A
KLV-32FA40A/37FA40A
1-1.  REAR COVER REMOVAL
SECTION 1:  DISASSEMBLY
1   Remove 2 screws from Terminals
2   Remove 1 screw (KLV-32FA40A ONLY)
 
Remove 4 screws (KLV-37FA40A ONLY)
3   Remove 20 screws
1-2.  BLOCK SWITCH PANEL REMOVAL (CONTAINS H1 BOARD)
1   Remove from bezel
2   Disconnect 1 connector
2
3
Rear Cover
1
Bezel
Block Switch Panel
1
2
13
KLV-32FA40A/37FA40A
KLV-32FA40A/37FA40A
1-3.  LED GUIDE/HM3 BOARD REMOVAL
1   Remove 2 screws
2   Disconnect 1 connector
HM3 Board
LED Guide
1
2
2
1
3
4
G2D (Power Unit)
G1 Bracket
G2 Bracket
G1D (Power Unit)
KLV-37FA40A 
KLV-32FA40A
1-4.  G1D BOARD/G2D BOARD (POWER UNIT) REMOVAL
1   Remove 4 connectors (KLV-37FA40A ONLY)
2   Remove 6 screws (KLV-37FA40A ONLY)
3   Remove 4 connectors (KLV-32FA40A ONLY)
4   Remove 4 screws (KLV-32FA40A ONLY)