– 11 –
KLV-26,32,32/H/S,37 S400A
RM-GA011
SECTION 4
WIRE DRESSING
CAUTION :
1.  Do not overpull the wires during dressing
--> avoid disconnection of wires.
2.  Make sure wires are kept away from
sharp edges, heatsinks & other
high-temperature parts.
4-1-1. Wire Dressing Overview for  
 
Non-CISPR model.
4-1-2. Wire Dressing Overview for CISPR model.
4-1-3. Dress LVDS cable with Sheet Core C.
 
(For Non-CISPR model)
4-1-4. Dress LVDS cable with Sheet Core C &
 
Shield Tape and screw LVDS cable's clamp  
 
on main bracket. (For CISPR model)
4-1.(KLV-26S400A)
Sheet Core C
LVDS cable
Datum
Datum
Sheet Core C
LVDS cable
Shield Tape
LVDS cable's
clamp
Screw
Make sure LVDS connector fully inserted 
with correct direction as shown.
LEGEND :
Hook
Slide Clamp
– 12 –
KLV-26,32,32/H/S,37 S400A
RM-GA011
4-1-5. Dress Connector Assy 13P at 
 
G1 bracket's hook,
4-1-6. Dress Connector Assy 14P+20P at 
 
G1 bracket's hook.
4-1-7. Dress Connector Assy 14P+20P with  
 
Slide Clamp (quantity: 2)
4-1-8. Dress Connector Assy 14P+20P on top of
 
Connector Assy.
4-1-9. Dress Connector Assy 14P+20P &  
 
Speaker Wire with Sheet Core C  
 
(quantity: 2).
4-1-10.  Apply Sheet Core C on LCD panel and  
 
dress Connector Assy 14P+20P & 
 
Speaker Wire with Sheet Core C.
Connector assy 14P+20P
Sheet Core C
Connector assy 14P+20P
Speaker Wire
Datum
Caution:
Make sure wire not over
this line.
Datum
Connector assy 13P
Connector assy 14P+20P
Connector assy 14P+20P
Pull wire straight 
Connector assy 13P
Datum
Datum
Sheet Core C
Speaker Wire
Connector assy 14P+20P
Caution : Pull away from
screw boss
Screw boss
Datum
– 13 –
KLV-26,32,32/H/S,37 S400A
RM-GA011
4-1-11.  Dress Speaker Wire(L) with LCD tape.
4-1-12.  Dress Connector Assy 14P+20P with 
 
LCD tape.
4-1-13.  Install AC Cord Holder on AC Power Cord.
 
(For Non-CISPR model)
4-1-14.  Install AC Cord Holder on AC Power Cord.
 
(For CISPR model)
Speaker Wire
Caution : Pull away from screw boss
Screw boss
Datum
LCD tape
130mm
AC Power Cord
AC Cord holder
AC Power Cord
130mm
70mm
Ferrite Core
Cable tie
Note: Make sure 
tighten cable tie and 
cut excess part.
Connector assy 14P+20P
Datum
LCD tape
AC Cord holder
– 14 –
KLV-26,32,32/H/S,37 S400A
RM-GA011
4-2-1. Wire Dressing Overview for 
 
Non-CISPR model
4-2-2. Wire Dressing Overview for CISPR model
4-2-3. Dress LVDS Cable with Sheet Core C (quantity: 2).
(For Non-CISPR model)
4-2. (KLV-32,32/H/S S400A)
Use UL tape
Use UL tape
location as guide line
Make sure LVDS connector fully inserted 
with correct direction as shown.
LVDS cable
Sheet Core C
Datum
Datum
Datum
UL Tape
Page of 72
Display

Click on the first or last page to see other KLV-26S400A / KLV-32S400A / KLV-37S400A service manuals if exist.