Sony KLV-26HG2 Service Manual ▷ View online

KLV-26HG2 (UC)      1-4
1-7. B BOARD REMOVAL
1-8. H1 AND MSX BOARDS REMOVAL
4
 B board 
3
 Four screws
    (+BVTT 3x6) 
1
 Two screws
    (+BVTT 3x6) 
2
 DVI bracket 
6
 MSX board 
3
 H1 board 
4
 Two screws
    (+BVTT 3x6) 
1
 Two screws
    (+BVTP 3x8) 
2
 Two screws
    (+BVTP 3x8) 
5
 Screw
    (+BVTP 3x10) 
KLV-26HG2 (UC)      1-5E
1-9. H2 BOARD REMOVAL
1-10. H3 BOARD REMOVAL
3
 H2 board 
1
 Four screws
    (+BVTP 3x8) 
2
 Two screws
    (+BVTP 3x8) 
2
 H3 board 
1
 Two screws
    (+BVWHTP 3x12) 
KLV-26HG2 (UC)      2-1
SECTION 2
ADJUSTMENTS
< PREPARATIONS >
1. Aging
• Input no signal and set the monitor to aging mode.
• Aging Setting
MON_CON_REG_2 = 152
2. Aging condition
Power supply : 120V AC, 60Hz
Time : More than 10 minutes
Temperature : 22ºC to 28ºC
Luminance : On aging mode setting
Note:
When the power is cycled between aging and W/B adjustment,
perform the aging in 30sec or more before the W/B
adjustment.
2-1. Adjustment of signal level.
2-1-1. Check AD calibration registration items.
1. Check that follows items are default .
2-1-2. Y signal AD calibration of TV/VIDEO
input.
1. Check “CO_CTRL” = 0
2. Set data as follows.
3. Input 0 IRE black full field with burst in video 1 input .
4. Send “READ_PW_INPUT_Y” command from ECS.
5. Check thgat the detection value of “PW_INPUT_Y” is within
the standard of the following column.
6. Input 100 IRE white full field with burst.
7. Send “ADJUST_Y_LEVEL_VIDEO” command from ECS.
The Y_LEVEL_CCP2_04 registration of the video range is
adjusted automatic by this command.
Adjustment value also is copied in the TV and S video range.
8. Check that the detection value of “PW_INPUT_Y” is within
the standard of the following column.
2-1-3. C signal AD calibration of TV/VIDEO
input.
1. Check “MON_CON_REG 1” = 3
2. Set data as follows.
3. Input 0 IRE black full field with burst in video input .
4. Send “READ_PW_INPUT_CB” command from ECS.
5. Check thgat the detection value of “PW_INPUT_CB” is
within the standard of the following column.
6. Input blue full field with burst.
7. Send “ADJUST_C_LEVEL_VIDEO” command from ECS.
The C_LEVEL_CCP2_05 registration of the video range is
adjusted automatic by this command.
The value that increased and redused offset data is copied in
the TV and S video range.
8. Check that the detection value of “PW_INPUT_CB” is within
the standard of the following column.
9. Input red full field with burst.
10. Send “READ_PW_INPUT_CR” command from ECS.
11. Check that the detection value of “PW_INPUT_CR” is within
the standard of the following column.
<Setting data>
COLOR
25
DYNA_PICT
 0 (OFF)
DC_TRAN
 0 (OFF)
<Setting data>
COLOR
25
DYNA_PICT
 0 (OFF)
DC_TRAN
 0 (OFF)
<Video(composit) input standard  value on blue full field>
Item
Standard
PW_INPUT_CB
225 
±
 2
<Video(composit) input detection value average on  0 IRE
black full field>
Item
Standard
PW_INPUT_Y
14 
±
 3
<Video(composit) input detection value average on 100
IRE white full field>
Item
Standard
PW_INPUT_Y
200 
±
 2
<Video(composit) input detection value average on 0
IRE black full field>
Item
Standard
PW_INPUT_CB
128 
±
 5
<Video(composit) input standard  value on red full field>
Item
Standard
PW_INPUT_CR
225 
±
 3
<Check registration items>
TARGET_PW_IN_Y
: Initial value
ADJ_Y_DEADBAND
: Initial value
ADJ_Y_LOOPATTEN
: Initial value
TARGET_PW_IN_C
: Initial value
ADJ_C_DEADBAND
: Initial value
ADJ_C_LOOPATTEN
: Initial value
AD_ADJ_TIME_OUT
: Initial value
AD_COLOR_OFFSET_TV
: Initial value
AD_COLOR_OFFSET_V
: Initial value
AD_COLOR_OFFSET_S
: Initial value
AD_COLOR_OFFSET_D1
: Initial value
AD_COLOR_OFFSET_D2
: Initial value
AD_COLOR_OFFSET_D3
: Initial value
AD_COLOR_OFFSET_D4
: Initial value
KLV-26HG2 (UC)      2-2
8. Check that the detection value of “PW_INPUT_CB” is within
the standard of the following column.
9. Input red full field with burst.
10. Send “READ_PW_INPUT_CR” command from ECS.
11. Check that the detection value of “PW_INPUT_CR” is within
the standard of the following column.
2-1-4. Y signal AD calibration of COMPONENT
input.
1. Check “CP_CTRL” = 0
2. Set data as follows.
3. Input 0 IRE black full field with burst in video 3 input .
4. Send “READ_PW_INPUT_Y” command from ECS.
5. Check thgat the detection value of “PW_INPUT_Y” is within
the standard of the following column.
6. Input 100 IRE white full field with burst.
7. Send “ADJUST_Y_LEVEL_D1” command from ECS.
The Y_LEVEL_CCP2_04 registration of the D1 range is ad-
justed automatic by this command.
Adjustment value also is copied in the D2, D3 and D4  range.
8. Check that the detection value of “PW_INPUT_Y” is within
the standard of the following column.
2-1-5. C signal AD calibration of COMPONENT
input.
1. Check “CP_CTRL” = 0
2. Set data as follows.
3. Input 0 IRE black full field with burst in video 3 input .
4. Send “READ_PW_INPUT_CB” command from ECS.
5. Check thgat the detection value of “PW_INPUT_CB” is
within the standard of the following column.
6. Input blue full field with burst.
7. Send “ADJUST_C_LEVEL_D1” command from ECS.
The C_LEVEL_CCP2_05 registration of the D1 range is ad-
justed automatic by this command.
The value that increased and redused offset data is copied in
the D2, D3 and D4  range.
<Setting data>
COLOR
25
DYNA_PICT
 0 (OFF)
DC_TRAN
 0 (OFF)
<Setting data>
COLOR
25
DYNA_PICT
 0 (OFF)
DC_TRAN
 0 (OFF)
<Video(composit) input detection value average on 0
IRE black full field>
Item
Standard
PW_INPUT_CB
128 
±
 5
<Video 3 input standard  value on blue full field>
Item
Standard
PW_INPUT_CR
225 
±
 3
<Video 3 input detection value average on 100 IRE white
full field>
Item
Standard
PW_INPUT_Y
200 
±
 2
<Video 3 input detection value average on 0 IRE black
full field>
Item
Standard
PW_INPUT_Y
14 
±
 3
<Video 3 input standard  value on blue full field>
Item
Standard
PW_INPUT_CB
225 
±
 2
Page of 90