DOWNLOAD Sony KLV-23S200A / KLV-26S200A / KLV-32S200A / KLV-40S200A / KLV-46S200A (serv.man2) Service Manual ↓ Size: 20.56 MB | Pages: 83 in PDF or view online for FREE

Model
KLV-23S200A KLV-26S200A KLV-32S200A KLV-40S200A KLV-46S200A (serv.man2)
Pages
83
Size
20.56 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
klv-23s200a-klv-26s200a-klv-32s200a-klv-40s200a-kl.pdf
Date

Sony KLV-23S200A / KLV-26S200A / KLV-32S200A / KLV-40S200A / KLV-46S200A (serv.man2) Service Manual ▷ View online

9
KLV-23S200A/26S200A/32S200A/40S200A/46S200A
KLV-23S200A/26S200A/32S200A/40S200A/46S200A
SAFETY CHECK-OUT
After correcting the original service problem, perform the following 
safety checks before releasing the set to the customer:
1.  Check the area of your repair for unsoldered or poorly soldered 
connections. Check the entire board surface for solder splashes and 
bridges.
2.  Check the interboard wiring to ensure that no wires are “pinched” or 
touching high-wattage resistors.
3.  Check that all control knobs, shields, covers, ground straps, and 
mounting hardware have been replaced. Be absolutely certain that 
you have replaced all the insulators.
4.  Look for unauthorized replacement parts, particularly transistors, 
that were installed during a previous repair. Point them out to the 
customer and recommend their replacement.
5.  Look for parts which, though functioning, show obvious signs of 
deterioration. Point them out to the customer and recommend their 
replacement.
6.  Check the line cords for cracks and abrasion. Recommend the 
replacement of any such line cord to the customer.
7.  Check the antenna terminals, metal trim, “metallized” knobs, screws, 
and all other exposed metal parts for AC leakage. Check leakage as 
described below.
Leakage Test
The AC leakage from any exposed metal part to earth ground and 
from all exposed metal parts to any exposed metal part having a 
return to chassis, must not exceed 0.5 mA (500 microamperes). 
Leakage current can be measured by any one of three methods.
1.  A commercial leakage tester, such as the Simpson 229 or RCA 
WT-540A. Follow the manufacturers’ instructions to use these 
instructions.
2.  A battery-operated AC milliampmeter. The Data Precision 245 
digital multimeter is suitable for this job.
3.  Measuring the voltage drop across a resistor by means of a VOM 
or battery-operated AC voltmeter. The “limit” indication is 0.75 
V, so analog meters must have an accurate low voltage scale. 
The Simpson’s 250 and Sanwa SH-63TRD are examples of 
passive VOMs that are suitable. Nearly all battery-operated digital 
multimeters that have a 2 VAC range are suitable (see Figure A).
How to Find a Good Earth Ground
A cold-water pipe is a guaranteed earth ground; the cover-plate 
retaining screw on most AC outlet boxes is also at earth ground. If the 
retaining screw is to be used as your earth ground, verify that it is at 
ground by measuring the resistance between it and a cold-water pipe 
with an ohmmeter. The reading should be zero ohms.
If a cold-water pipe is not accessible, connect a 60- to 100-watt 
trouble- light (not a neon lamp) between the hot side of the receptacle 
and the retaining screw. Try both slots, if necessary, to locate the hot 
side on the line; the lamp should light at normal brilliance if the screw 
is at ground potential (see Figure B).
To Exposed Metal
Parts on Set
0.15 µF
Earth Ground
AC
Voltmeter
(0.75V)
Trouble Light
AC Outlet Box
Ohmmeter
Cold-water Pipe
Figure A. Using an AC voltmeter to check AC leakage.
Figure B. Checking for earth ground.
10
KLV-23S200A/26S200A/32S200A/40S200A/46S200A
KLV-23S200A/26S200A/32S200A/40S200A/46S200A
SELF-DIAGNOSTIC FUNCTION
Self Diagnosis
Supported model
Control Buttons
PIC OFF/TIMER
STANDBY
POWER
TV/VIDEO
VOLUME
MENU
CHANNEL
POWER
Description of LED Indictors
LED
LED Type
Description
* Light is green when the TV set is on
* Functions as failure indicator
Blinks green in aging mode
TIMER LED
Red LED
Lights when timer is set
PIC OFF LED
Green LED
Lights when power saving setting is set to 
picture off (See Instruction Manual)
POWER LED
Red/Green LED
11
KLV-23S200A/26S200A/32S200A/40S200A/46S200A
KLV-23S200A/26S200A/32S200A/40S200A/46S200A
LED Control
!"##
"##
"##
"##
!##$&'!&+!
! +!<"=>?@JX
&&& Z
\! &+!+ '$!
!&'
!"##
^&_!
"##
"##
`&+!+ '$!!&! X
{&$!
|&}
"##
"##
{&$!+$!+&#&JX
$ J!#& !&J&
&
|&_!
"##
"##
& &+&#&JX
J&&!&
&+$!"##
^&_!
^&_!
"##
<&'X~J++!
^&_!
^&"!
"##
@^>>=€`>}&$!&
'!
^&_!
^&_!
"##
@^>>=€`>}&&
&+$!"##
"##
^&"!
"##
"<=€`>}&'!
&##
^&_!
^&"!
"##
"<=€`>}&'!
&
^&_!
^&_!
"##
"<=€`>}&&&+$!
"##
@=<‚|ƒ
"##
"##
^&}
@=<‚|ƒ„
=€`>}"<
"##
^&"!
^&}
}>`}…@
@=<‚|ƒ^>‚
=€`>}^>‚„
€=†}>"{{^>‚
@^>>=€`>}
"<=€`>}
@==†@
">}^>‚
The units in this manual contain a self-diagnostic function. If an error occurs, the POWER LED will automatically begin to fl ash. The number of times 
the LED fl ashes translates to a probable source of the problem. A defi nition of the POWER LED fl ash indicators is listed in the instruction manual for 
the user’s knowledge and reference. If an error symptom is diffi cult to reproduced use the Remote Commander to display the record that is stored at 
the internal NVM to specify the cause of the failure.
Diagnostic Test Indicators
When an error occurs, the POWER LED will fl ash a set number of times to indicate the possible cause of the problem. If there is more than one error, 
the LED will identify the fi rst of the problem areas. If the errors occur simultaneously, the one that corresponds to the fewest fl ashes is identifi ed fi rst.
Results for all of the following diagnostic items are displayed on screen.  No error has occurred if the screen displays a “0”.
<$ J!#=&
">}^>‚|&
`&!&€
=&
J! †!‡~‚^>}=
=&
J! ‚‡„‡!‡~‚^>}=
=&
J! ‡~‚^>}=
=&
|+&{&$!
=&
J! `&!‡
=&
J! @'!‡
=&
€!= '!$!}&~ &X'&
=&
€
12
KLV-23S200A/26S200A/32S200A/40S200A/46S200A
KLV-23S200A/26S200A/32S200A/40S200A/46S200A
SECTION 1:  DISASSEMBLY
1-1. REAR 
COVER 
REMOVAL
 
 Rear  Cover
 
 10 Screws, +BVTP2 4X16 (KVL-23S200A ONLY) 
 
 12 Screws, +BVTP2 4X16 (KVL-26S200A/32S200A/40S200A) 
 
 2 Screws, +PSW M4X16 (KVL-23S200A/26S200A) 
 
 2 Screws, +PSW M6X16 (KVL-32S200A/40S200A/46S200A) 
 
 18 Screws, +BVTP2 4X16 (KVL-46S200A ONLY) 
 
2 Screws, 
+BVPT 3X12 TYPE2 IT-3
1
2
3
(NOTE: Illustrations created based on KLV-26S200A)
Page of 83
Display

Click on the first or last page to see other KLV-23S200A / KLV-26S200A / KLV-32S200A / KLV-40S200A / KLV-46S200A (serv.man2) service manuals if exist.