Brand
Device
TV
File
klv-19t400a-klv-19t400g-klv-19t400w.pdf
Date

Sony KLV-19T400A / KLV-19T400G / KLV-19T400W Service Manual ▷ View online

– 12 –
KLV-19T400A,T400G,T400W
RM-GA013
 4-1-8. Wire Harness Dressing
 4-1-9. 
Connector Assy 4P, 11P, SP Conn Assy 4P and 5P* Dressing
3) Dress SP Conn Assy 4P; Conn Assy 11P and Conn Assy 4P using Sheet Core, C as shown.
4) Insert Conn Assy 4P; Conn Assy 11P; SP Conn Assy 4P and
 
Conn Assy 5P* (for 19T400W model only) into Purse Lock (S) Ø 12.
Sheet Core,C 
Purse Lock (S) Ø 12
Figure 9
19T400A models
*19T400W models
19T400G models
SP Conn Assy 4P
Conn Assy 
Conn Assy 5P*
Conn Assy 
1) Dress Conn Assy 4P; Conn Assy 11P; SP Conn Assy 4P and Conn Assy 5P* (for 19T400W) using Sheet Core, C as shown.
2) Use pin, wire A6204 to wire dress all wires keep it away from rear cover screw hole.
*For 19T400W model onl
y
Rear cover screw hole
Pin, wire A6204
Sheet Core, C
Conn Assy 11P
Conn Assy 4P
19T400A models
19T400G models
19T400W models
Figure b
Caution: Dress all wires below panel's height limit. 
Ensure that wires do not block screw hole
(prevent them from being sandwiched when inserting screw to rear cover)
Conn Assy 4P
Figure a
SP Conn Assy 4P
Bend Conn Assy 5P*
towards the right before
dressing
Pin, wire A6204
Rear cover screw hole
Sheet Core, C
Conn Assy 11P
Ensure both Conn Assy 11P
and Conn Assy 4P are dressed
towards the left (below J-bracket)
SP Conn Assy 4P
3
4
– 13 –
KLV-19T400A,T400G,T400W
RM-GA013
 4-1-10. SP Conn Assy 4P and LVDS Harness Dressing
 4-1-11. Connector Assy 10P Dressing
4-1-12. Dressing for 19T400W models only
Follow figures below for SP Conn Assy 4P and LVDS Harness dressing.
SP Conn Assy 4P
Tape, LCD attached to WHT+BLK end of wire
Attach Sheet Core, C 
C
Figure (c)
SP Conn Assy 4P
19T400W Non-CISPR models
Attach Sheet Core, C 
C
19T400A CISPR models
SP Conn Assy 4P
Tape, LCD attached to WHT+BLK end of wire
Dress SP Conn Assy 4P below LVDS harness 
Tape, LCD attached to WHT+BLK end of wire
Screw earth clamp (X1)
Dress SP Conn Assy 4P below LVDS harness
Dress SP Conn Assy 4P
below LVDS harness 
Figure (a)
Figure (b)
Figure (d)
SP Conn Assy 4P
19T400G Non-CISPR models
Attach Sheet Core, C
Tape, LCD attached to 
WHT+BLK end of wire
Dress SP Conn Assy 4P below LVDS harness
Caution: Dress wires 
downward towards the 
tweeter. Ensure capacitor 
does not touch tweeter or 
any coductive parts.
1
1
2
2
3
3
1
1
2
2
2
3
3
1) Dress Connector Assy 7P as shown.
2) Next, dress Conn Assy 3P by inserting the wire into J-bracket's hook.
Insert Conn Assy 3P
into J -bracket's hook
Dress Conn Assy 7P
below LVDS Harness
Conn Assy 3P
SP Conn Assy 4P 
Conn Assy 7P
19T400W 
LVDS Harness
Dress Connector Assy 10P using Tape, LCD (2X) as shown.
Figure 12
CN1000
Use datum line as a guide 
id
Common for all
19T400 models
Use Tape, LCD (2X) to
attach Conn Assy 10P to
main bracket
CN3001
Conn Assy 10P is
below wires
Use datum line as a guide 
Conn Assy 10P
– 14 –
KLV-19T400A,T400G,T400W
RM-GA013
 4-1-13. AC Power Cord Wire Dressing 
 
(Non-CISPR)
4-1-14.  AC Power Cord Wire Dressing (CISPR)
1) Install AC cord holder to AC power cord at specified position as shown.
2) Then install the AC power cord with holder into AC cord bracket.
Non-CISPR model
Figure (a)
Non-CISPR 
60 ± 5mm 
AC power cord is above
Lead Assy, Earth
Install AC power cord with
holder into AC cord bracket
AC cord bracket 
1) Install Ferrite Core to AC power cord at specified position as shown.
2) Next, install AC cord holder to AC power cord at specified position.
3) Insert AC power cord into slide, clamp to secure it in position.
4) Lastly, install the AC power cord with holder into AC cord bracket.
180 ± 
80± 5mm
Install AC power cord with
holder into AC cord bracket
CISPR model
AC power cord is above
Lead Assy, Earth
Figure (b)
CAUTION:
1.  Ensure that AC power cord is not stressed whilst inserting it into AC
 
cord bracket and slider, clamp (CISPR model).
Attach AC Power Cord into Slide, clamp 
AC cord bracket
1
2
4
3
– 15 –
KLV-19T400A,T400G,T400W
RM-GA013
5-1. Accessing Diagnostic Menu
1.
While TV set on standby, press the following sequence on
the Remote commander (RMGA013).
The following menu will appear on the screen
2.
To quit the diagnostic menu, turn off and on the set.
5-2. Viewing the Service Mode Display
1.
While TV on standby mode, press the following sequence
on the Remote commander.
(if wrong key is pressed or passed 3 seconds during each
process, cancel entering the self-diagnosis display.)
Example on screen display:
2.
To reset, press 8 – 0 –     .
3.
To Exit, press the <I/
1
> key .
SECTION 5
SERVICE ADJUSTMENTS
Figure 1
On screen
display
Channel 5
Volume (-)
POWER
MAIN_POWER_ERROR
5V_POWER_ERROR
AUDIO_ERROR
BALK_LIGHT_ERROR
 TEMP_ERROR
0
0
0
0
0
5-3. Control keys via Remote Commander.
Buttons on the Remote Commander to access the service
menu items and adjust the data values.
5-4. Adjustment Method
5-4-1. Aging
1.
While TV on standby mode, press the following sequence
on the Remote commander.
2.
Select AGING with 
2
 or 
5
 On the Remote Commander.
3.
Select AGING MODE with 
1
 or 
4
 On the Remote
Commander.
4.
Select data value with 
3
 or 
6
 On the Remote
Commander to 1 to enable. Refer to Service Items
(Table 1) page 17
5.
Press <I/
1
> to exit.
6.
When exit it will have the new data value and start aging.
7.
Aging condition:
a) Supply voltage : Rating
b) Time: More than 20 minutes
c) Ambient Temp: 22-28 degrees
d) Input : Set no signal except digital and analog
    RF(Video/Component/PC)
Example on screen display:
On screen
display
Channel 5 
Volume (+)
POWER
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
T  V                                                             S  E  R V I C E
0  0  0    
B   
  
M E                                  
0  0  0     W  P  R  _
  
                          2  5  5           
                                                                                    
   L  O  C   T  O  P        P  R  O G R A M :   
          
                           G  T  V :               
M R 1  .  0  .  2
          
                           N  V  M :               
T D 0  .  1  0  0
          
                                                                                    
                                                                                    
                                                                                    
                                                                                    
                                                                                    
                                                                                    
                                                                                    
                                                                                    
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
       
 
 
 
 
PROGRAM: Show the Application
 
version
 
GTV: Show the
 
GTV Libra
r
y version
 
NVM:
 
Show the NVM version in the NVM data 
(4bytes ASCII data)
  
 
[Data]
 
Within 7 characters 
[Category/Item name] Within 17 
characters
 
T M 0  .  0 7 0
W
Categry
Item
C
W
On screen
display
Channel 5 
Volume (+)
POWER
PROGRAM: Show the Application version
GTV: Show the GTV Library version
NVM: Show the NVM version in the NVM data 
(4bytes ASCII data)
T    V
0    0     0
0    0     0
L    O    C     T     O    P
A    G     I     N    G
A    G     I     N    G
P    R    O    G     R    A    M     :
G    T    V      :
N    V    M      :
M    O    D    E   
S    E    R    V    I    C    E
T    M     0    .    0    7    0
M    R     1    .    0    .    2
T    D     0    .    1    0    0
1
Page of 29
Display

Click on the first or last page to see other KLV-19T400A / KLV-19T400G / KLV-19T400W service manuals if exist.