Sony KE-P37M1 / KE-P42M1 Service Manual ▷ View online
KE-P37M1/P42M1 (AEP) 1-9
1-2-7. PDP PANEL REMOVAL
4
Three screws
(+BVTP 3x12 )
1
Six screws
(+PSW 3x8 )
2
Bracket
5
Bracket
6
Two screws
(+BVTP 4x16 )
8
Two screws
(+BVTP 4x16 )
0
Two screws
(+BVTP 4x16 )
7
Bracket (H)
9
Bracket (H)
qa
Bracket (V)
qd
Bracket (V)
qs
Two screws
(+BVTP 4x16 )
3
Plasma display panel
qf
Glass optical filter
KE-P37M1/P42M1 (AEP) 1-10E
1-2-8. H1 AND H3 BOARDS REMOVAL
1-2-9. H2 BOARD REMOVAL
1
Six screws
(+BVTP 3x12)
2
Front terminal assy
3
Two screws
(+BVTP 3x12)
5
Two screws
(+BVTP 3x12)
4
H3 board
6
H1 board
1
Two screws
(+BVTP 3x12)
2
H2 board
KE-P37M1/P42M1 (AEP) 2-1
SECTION 2
ADJUSTMENTS
2-1. AGING
2-1-1. Aging setting
1.
To set aging mode on no input signal, change the register.
And do the “service save”.
And do the “service save”.
[Aging setting]
“MON_CON_REG_2” = 185
“AGING_COLOR” = 1
“MON_CON_REG_2” = 185
“AGING_COLOR” = 1
2-1-2. Aging condition
Power supply : 220-240 V (50Hz)
Time
Time
: More than 10 minutes
Temperature
: 22ºC ~ 28ºC
Luminance
: On aging mode setting
Note:
After aging, if power was shut down until W/B adjusutment, shall
be adjusted W/B after aging more than 30 second.
be adjusted W/B after aging more than 30 second.
2-2. ADJUSTMENT OF SIGNAL LEVEL
This adjustment shall be used ECS.
2-2-1. Check AD (2163 case) calibration registra-
tion items
1.
Select AV1 and input PAL signal.
2.
Set following items.
3.
Check that following items is defalt.
2-2-2. Y signal AD calibration of 2163 decode
1.
Check “MON_CON_REG_1” = 3.
(TIMING_AUTO_DETECT is Enable)
(TIMING_AUTO_DETECT is Enable)
2.
Input 0 IRE black full field with burst in AV1.
3.
Send “READ_PW_INPUT_Y” command from ECS.
4.
Check that the detection value of “PW_INPUT_Y” is within
the standard of following column.
the standard of following column.
5.
Input 100 IRE white full field with burst.
6.
Send “ADJUST_Y_LEVEL_VIDEO” command from ECS.
The Y_LEVEL_CCP2_04 registration of the video range is
adjusted automatic by this command.
Adjustment value also is copied in the proper NVM area.
The Y_LEVEL_CCP2_04 registration of the video range is
adjusted automatic by this command.
Adjustment value also is copied in the proper NVM area.
Item
Data
PICTURE_MODE
0 (Live)
COLOR
25
DYNA_PICT
0 (Off)
DC_TRAN
0 (Off)
TARGET_PW_IN_Y
ADJ_Y_DEADBAND
ADJ_Y_LOOPATTEN
TARGET_PW_IN_C
ADJ_C_ DEADBAND
ADJ_C_ LOOPATTEN
AD_ADJ_TIME_OUT
ADJ_Y_DEADBAND
ADJ_Y_LOOPATTEN
TARGET_PW_IN_C
ADJ_C_ DEADBAND
ADJ_C_ LOOPATTEN
AD_ADJ_TIME_OUT
Item
Standard
PW_INPUT_Y
Less than 304
7.
Check that the detection value of “PW_INPUT_Y” is within
the standard of following column.
the standard of following column.
2-2-3. C signal AD calibration of 2163 decode
1.
Check “MON_CON_REG_1” = 3.
(TIMING_AUTO_DETECT is Enable)
(TIMING_AUTO_DETECT is Enable)
2.
Input 0 IRE black full field with burst.
3.
Send “READ_PW_INPUT_CB” command from ECS.
4.
Check that the detection value of “PW_INPUT_CB” is
within the standard of following column.
within the standard of following column.
5.
Input blue full field with burst.
6.
Send “ADJUST_C_LEVEL_VIDEO” command from ECS.
The C_LEVEL_CCP2_05 registration of the video range is
adjusted automatic by this command.
Adjustment value also is copied in the proper NVM area.
The C_LEVEL_CCP2_05 registration of the video range is
adjusted automatic by this command.
Adjustment value also is copied in the proper NVM area.
7.
Check that the detection value of “PW_INPUT_CB” is
within standard of following column.
within standard of following column.
8.
Input red full field with burst.
9.
Send “READ_PW_INPUT_CR” command from ECS.
10. Check that the detection value of “PW_INPUT_CR” is
within standard of following column.
2-2-4. Check AD (CCP2 case) calibration registra-
tion items
1.
Select AV3 and input PAL signal
2.
Set following items.
3. Check that following items is defalt.
Item
Standard
PW_INPUT_Y
3888
±
16
Item
Standard
PW_INPUT_CB
Less than 304
Item
Standard
PW_INPUT_CB
3724
±
16
Item
Data
PICTURE_MODE
0 (Live)
COLOR
25
DYNA_PICT
0 (Off)
DC_TRAN
0 (Off)
TARGET_PW_IN_Y
ADJ_Y_DEADBAND
ADJ_Y_LOOPATTEN
TARGET_PW_IN_C
ADJ_C_ DEADBAND
ADJ_C_ LOOPATTEN
AD_ADJ_TIME_OUT
ADJ_Y_DEADBAND
ADJ_Y_LOOPATTEN
TARGET_PW_IN_C
ADJ_C_ DEADBAND
ADJ_C_ LOOPATTEN
AD_ADJ_TIME_OUT
Item
Standard
PW_INPUT_CR
3340
±
320
KE-P37M1/P42M1 (AEP) 2-2
2-2-5. Y signal AD calibration of CCP2 decode
1.
Check “MON_CON_REG_1” = 3.
(TIMING_AUTO_DETECT is Enable)
(TIMING_AUTO_DETECT is Enable)
2.
Input 0 IRE black full field with burst.
3.
Send “READ_PW_INPUT_Y” command from ECS.
4.
Check that the detection value of “PW_INPUT_Y” is
within the standard of following column.
within the standard of following column.
5.
Input 100 IRE white full field with burst.
6.
Send “ADJUST_Y_LEVEL_VIDEO” command from ECS.
The Y_LEVEL_CCP2_04 registration of the video range is
adjusted automatic by this command.
Adjustment value also is copied in the proper NVM area.
The Y_LEVEL_CCP2_04 registration of the video range is
adjusted automatic by this command.
Adjustment value also is copied in the proper NVM area.
7.
Check that the detection value of “PW_INPUT_Y” is within
the standard of following column.
the standard of following column.
2-2-6. C signal AD calibration of CCP2 decode
1.
Check “MON_CON_REG_1” = 3.
(TIMING_AUTO_DETECT is Enable)
(TIMING_AUTO_DETECT is Enable)
2.
Input 0 IRE black full field with burst.
3.
Send “READ_PW_INPUT_CB” command from ECS.
4.
Check that the detection value of “PW_INPUT_CB” is
within the standard of following column.
within the standard of following column.
5.
Input blue full field with burst.
6.
Send “ADJUST_C_LEVEL_VIDEO” command from ECS.
The C_LEVEL_CCP2_05 registration of the video range is
adjusted automatic by this command.
Adjustment value also is copied in the proper NVM area.
The C_LEVEL_CCP2_05 registration of the video range is
adjusted automatic by this command.
Adjustment value also is copied in the proper NVM area.
7.
Check that the detection value of “PW_INPUT_CB” is
within standard of following column.
within standard of following column.
8.
Input red full field with burst.
9.
Send “READ_PW_INPUT_CR” command from ECS.
10. Check that the detection value of “PW_INPUT_CR” is
within standard ofi following column.
2-2-7. Check AD (Component case) calibration
registration items
1.
Select AV4 and input 575i signal.
2.
Set following items.
Item
Standard
PW_INPUT_Y
Less than 304
Item
Standard
PW_INPUT_CB
Less than 304
Item
Standard
PW_INPUT_Y
3888
±
16
Item
Standard
PW_INPUT_CB
3184
±
16
Item
data
PICTURE_MODE
0 (Live)
COLOR
25
DYNA_PICT
0 (Off)
DC_TRAN
0 (Off)
3.
Check that following items is defalt.
2-2-8. Y signal AD calibration of component input
1.
Check “MON_CON_REG_1” = 3.
(TIMING_AUTO_DETECT is Enable)
(TIMING_AUTO_DETECT is Enable)
2.
Input 0 IRE black full field with burst in AV3.
3.
Send “READ_PW_INPUT_Y” command from ECS.
4.
Check that the detection value of “PW_INPUT_Y” is within
the standard of following column.
the standard of following column.
5.
Input 100 IRE white full field with burst.
6.
Send “ADJUST_Y_LEVEL_VIDEO” command from ECS.
The Y_LEVEL_CCP2_04 registration of the video range is
adjusted automatic by this command.
Adjustment value also is copied in the proper NVM area.
The Y_LEVEL_CCP2_04 registration of the video range is
adjusted automatic by this command.
Adjustment value also is copied in the proper NVM area.
7.
Check that the detection value of “PW_INPUT_Y” is within
the standard of following column.
the standard of following column.
2-2-9. C signal AD calibration of componet input
1.
Check “MON_CON_REG_1” = 3.
(TIMING_AUTO_DETECT is Enable)
(TIMING_AUTO_DETECT is Enable)
2.
Input 0 IRE black full field with burst.
3.
Send “READ_PW_INPUT_CB” command from ECS.
4.
Check that the detection value of “PW_INPUT_CB” is
within the standard of following column.
within the standard of following column.
5.
Input blue full field with burst.
6.
Send “ADJUST_C_LEVEL_VIDEO” command from ECS.
The C_LEVEL_CCP2_05 registration of the video range is
adjusted automatic by this command.
Adjustment value also is copied in the proper NVM area.
The C_LEVEL_CCP2_05 registration of the video range is
adjusted automatic by this command.
Adjustment value also is copied in the proper NVM area.
7.
Check that the detection value of “PW_INPUT_CB” is
within standard of following column.
within standard of following column.
8.
Input red full field with burst.
9.
Send “READ_PW_INPUT_CR” command from ECS.
10. Check that the detection value of “PW_INPUT_CR” is
within standard ofi following column.
Item
Standard
PW_INPUT_Y
Less than 304
Item
Standard
PW_INPUT_Y
3888
±
16
Item
Standard
PW_INPUT_CB
Less than 304
Item
Standard
PW_INPUT_CB
3760
±
16
TARGET_PW_IN_Y
ADJ_Y_DEADBAND
ADJ_Y_LOOPATTEN
TARGET_PW_IN_C
ADJ_C_ DEADBAND
ADJ_C_ LOOPATTEN
AD_ADJ_TIME_OUT
ADJ_Y_DEADBAND
ADJ_Y_LOOPATTEN
TARGET_PW_IN_C
ADJ_C_ DEADBAND
ADJ_C_ LOOPATTEN
AD_ADJ_TIME_OUT
Item
Standard
PW_INPUT_CR
2832
±
320
Item
Standard
PW_INPUT_CR
3200
±
320
Click on the first or last page to see other KE-P37M1 / KE-P42M1 service manuals if exist.