SERVICE MANUAL
SPECIFICATIONS
KE-50MR1
FLAT PANEL COLOR TELEVISION
AEP Model
Media Receiver Unit (MBT-MR1)
Power Requirement: 220-240V AC; 50/60 Hz
Power Consumption: 27 W
Standby Power Consumption: 0.6 W
Dimensions (w x h x d): 
Approx. 430 x 105 x 360 mm
Weight:
Approx. 6 kg
Display Unit (PDM-5000)
Power Requirement: 100-240V AC; 50/60 Hz
Screen Size: 50inches 
Approx. 127 cm measured 
diagonally
Display Resolution: 
1365 dots (horizontal) x 768 lines 
(vertical)
Power Consumption: 540W
Standby Power Consumption: 0.6W
Dimensions (w x h x d): 
Approx. 1,573 x 856 x 108 mm
Weight: 
Approx. 53 kg
Panel System:
Plasma Display Panel
TV system: 
Depending on your country selection: 
B/G/H, D/K, L, I 
Colour system:
PAL, SECAM 
NTSC 3.58, 4.43 (only Video In)
Aerial:
75 ohm external terminal for VHF/UHF
Channel Coverage:
VHF: E2-E12
UHF: E21-E69
CATV: S1-S20
HYPER: S21-S41
D/K: R1-R12, 
R21-R69
L: 
F2-F10, B-Q, F21-F69
I: UHF 
B21-B69
Rear Terminals:
1/
21-pin Scart connector (CENELEC 
standard) including audio/video input, 
RGB input, TV audio/video output.
2/
21-pin Scart connector (CENELEC 
standard) including audio/video input, 
RGB input, TV audio/video output.
3/
 (SMARTLINK; selectable) 
21-pin Scart connector (CENELEC 
standard) including audio/video input, S 
video input, selectable audio/video 
output and Smartlink interface.
4/
 (SMARTLINK; selectable)
21-pin Scart connector (CENELEC 
standard) including audio/video 
input, RGB input, selectable audio/
video output, and Smartlink interface.
5
Y:
1 Vp-p, 75 ohms, 0.3V negative sync
P
B
: 0.7 Vp-p, 75 ohms
P
R
: 0.7 Vp-p, 75 ohms
5
audio input (phono jacks)
500 m Vrms (100% modulation), 
Impedance: 47 kilo ohms
SUB WOOFER: phono jack
: audio outputs (Left/Right) - phono jacks
 CENTRE SPEAKER IN:
 Max. 180W (6-ohms)
CTRL S: minijack
AV MOUSE: minijack
S
5
5
5
5
5
5
5
5
KE-50MR1(AEP)
2
Front Terminals:
6
S video input (4-pin mini DIN):
Y: 1 Vp-p, 75-ohms unbalanced, sync 
negative
C: 0.286 Vp-p (Burst signal), 75 ohms
6
video input (phono jack):
1 Vp-p, 75-ohms unbalanced, sync 
negative
6
audio input (phono jacks):
500 m Vrms (100% modulation), 
Impedance: 47 kilo ohms
 headphones jack
PC
PC Input (15-Dsub)
G: 0.7 Vp-p, 75 ohms, non Sync on Green
B:
0.7 Vp-p, 75 ohms, non Sync on Green
R:
0.7 Vp-p, 75 ohms, non Sync on Green
HD:1-5 Vp-p
VD: 1-5 Vp-p
PC
PC audio input: minijack
 Memory Stick Slot
Sound Output:
15W x 2
Accessories supplied:
• One Remote Control (RM-972)
• Two size AAA batteries (R03 type)
• One Display Interface Cable
• One Coaxial Cable
• One AV Mouse
• Two Mains Leads (Type C-4)
• Two Mains Leads (Type BF)
• Two Mains Leads (Type C-5)
Main leads Type BF and Type C-5 
may not be supplied depending on 
the country.
• One Cleaning cloth 
• One Mains plug holder
S
Other features:
• Teletext, Fastext, TOPtext
• Sleep Timer
• Smartlink (direct link between your TV set 
and a compatible VCR. For more 
information on Smartlink, please refer to the 
Instruction Manual of your VCR).
It's available either 
3 or 
4. 
(Selectable)
• TV system Autodetection
• Auto Format
PC Input Timing:
Input signal frequency
Horizontal:  15.6 - 90 kHz
Vertical:
 48 - 85 Hz
Maximum Resolution: 1600 dots x 1200 lines
KE-50MR1(AEP)
3
LEAKAGE  TEST
The AC leakage from any exposed metal part to earth ground and from all
exposed metal parts to any exposed metal part having a return to chassis,
must not exceed 0.5 mA (500 microamperes).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA WT-
540A. Follow the manufacturers’ instructions to use these instruments.
2. A battery-operated AC milliammeter. The Data Precision 245 digital
multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM or
battery-operated AC voltmeter. The “limit” indication is 0.75 V, so
analog meters must have an accurate low-voltage scale. The Simpson 250
and Sanwa SH-63Trd are examples of a passive VOMs that are suitable.
Nearly all battery operated digital multimeters that have a 2 V AC range
are suitable.  (See Fig. A)
After correcting the original service problem, perform the following safety
checks before releasing the set to the customer:
1. Check the area of your repair for unsoldered or poorly-soldered
connections. Check the entire board surface for solder splashes and
bridges.
2. Check the interboard wiring to ensure that no wires are “pinched” or
contact high-wattage resistors.
3. Check that all control knobs, shields, covers, ground straps, and
mounting hardware have been replaced. Be absolutely certain that you
have replaced all the insulators.
4. Look for unauthorized replacement parts, particularly transistors, that
were installed during a previous repair. Point them out to the customer
and recommend their replacement.
5. Look for parts which, though functioning, show obvious signs of
deterioration. Point them out to the customer and recommend their
replacement.
6. Check the line cords for cracks and abrasion. Recommend the
replacement of any such line cord to the customer.
7. Check the B+ and HV to see if they are specified values. Make sure your
instruments are accurate; be suspicious of your HV meter if sets always
have low HV.
8. Check the antenna terminals, metal trim, “metallized” knobs, screws, and
all other exposed metal parts for AC Leakage. Check leakage as
described right.
Fig. A. Using an AC voltmeter to check AC leakage.
1.5 k
0.15 
µ
F
AC
Voltmeter
(0.75 V)
To Exposed Metal
Parts on Set
Earth Ground
SAFETY  CHECK-OUT
KE-50MR1(AEP)
4
AVERTISSEMENT!!
ATTENTION AUX COMPOSANTS RELATIFS À LA SÉCURITÉ!!
LES COMPOSANTS IDENTIFIÉS PAR UNE TRAME ET UNE
MARQUE 
!
 SONT CRITIQUES POUR LA SÉCURITÉ. NE LES
REMPLACER QUE PAR UNE PIÈCE PORTANT LE NUMÉRO
SPECIFIÉ. LES RÉGLAGES DE CIRCUIT DONT L’IMPORTANCE EST
CRITIQUE POUR LA SÉCURITÉ DU FONCTIONNEMENT SONT
IDENTIFIÉS DANS LE PRÉSENT MANUEL.  SUIVRE CES
PROCÉDURES LORS DE CHAQUE REMPLACEMENT DE
COMPOSANTS CRITIQUES, OU LORSQU’UN MAUVAIS
FONCTIONNEMENT EST SUSPECTÉ.
WARNING!!
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY SHADING AND MARK 
!
  ON THE
SCHEMATIC DIAGRAMS, EXPLODED VIEWS AND IN THE
PARTS LIST ARE CRITICAL FOR SAFE OPERATION. REPLACE
THESE COMPONENTS WITH SONY PARTS WHOSE PART
NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN
SUPPLEMENTS PUBLISHED BY SONY. CIRCUIT ADJUST-
MENTS THAT ARE CRITICAL FOR SAFE OPERATION ARE
IDENTIFIED IN THIS MANUAL. FOLLOW THESE PROCEDURES
WHENEVER CRITICAL COMPONENTS ARE REPLACED OR IM-
PROPER OPERATION IS SUSPECTED.
Page of 127
Display

Sony KE-50MR1 Service Manual ▷ Download

  • DOWNLOAD Sony KE-50MR1 Service Manual ↓ Size: 13.1 MB | Pages: 127 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sony KE-50MR1 in PDF for free, which will help you to disassemble, recover, fix and repair Sony KE-50MR1 TV. Information contained in Sony KE-50MR1 Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.