Sony KE-42TS2E / KE-42TS2U Service Manual ▷ View online
46
Suspected faulty board
(In the order of higher probability of defect)
ERR
code
code
Detect
position
(board)
Contents
(1) (2) (3) (4) (5) (6) (7)
Remarks
81
PSU
Va power voltage is excessive
PSU
LOGIC
82
Va power startup is faulty.
ADM1 - 8 PSU
LOGIC
ABUS-L ABUS-R
99
Va power current is excessive (during
operation)
operation)
ADM1 - 8 ABUS-L ABUS-R PSU
LOGIC
9B
Va power current is excessive (during startup) ADM1 - 8 ABUS-L ABUS-R PSU
LOGIC
9D
Va power current is excessive (during
operation)
operation)
ADM1 - 8 ABUS-L ABUS-R PSU
LOGIC
Excess current is
detected in ACCC
operation.
operation.
A5
ADM1
ADM1 has abnormal heat generation.
ADM1
PSU
LOGIC
A9
ADM2
ADM2 has abnormal heat generation.
ADM2
PSU
LOGIC
AD
ADM3
ADM3 has abnormal heat generation.
ADM3
PSU
LOGIC
B1
ADM4
ADM4 has abnormal heat generation.
ADM4
PSU
LOGIC
B5
ADM5
ADM5 has abnormal heat generation.
ADM5
PSU
LOGIC
B9
ADM6
ADM6 has abnormal heat generation.
ADM6
PSU
LOGIC
BD
ADM7
ADM7 has abnormal heat generation.
ADM7
PSU
LOGIC
C5
ADM8
ADM8 has abnormal heat generation.
ADM8
PSU
LOGIC
It can possibly occur
depending on screen
display.
depending on screen
display.
E2
LOGIC
5V power startup is faulty.
X-SUS
Y-SUS
PANEL
PSU ABUS-L ABUS-R LOGIC
FC
PSU
Detection error of Vs and Va voltage.
PSU
LOGIC
47
5
Disassembling and Reassembling
Unless otherwise specified, use the torque screwdriver for screw tightening, following the
tightening torques below.
Screw size
Tightening torque
M 3
0. 69±0.049Nm (7±0.5kg·cm)
M 4
1.18±0.098Nm (12±1.0kg·cm)
5.1 Exploded
View
1
2
3
4
5
6
8
7
9
10
11
12
48
5.2
X-SUS Circuit Board Removal/Installation Procedure
When removing the circuit board after the main power is turned on/off, wait for at least
one minute before starting to remove the circuit board.
If the circuit board removal is started immediately after turning off the main power,
it can result in electric shock or damage to the circuit due to residual electric charge.
Remove the circuit board following the steps below. To install the circuit board, reverse
the removal procedure.
(1)
Remove the fixing screws (M3×8) at 9 locations.
(2)
Release the lock of the FPC connector (CN21) and disconnect the signal cable.
(3)
Disconnect the cables from the VH connectors (CN22, CN23).
(4)
Pull out the XSUS board horizontally and disconnect the connectors (CN24, CN25).
Note
* On handling the FPC connector
To release the lock, release it by gently flipping
it with the nail of the thumb or forefinger.
Never pinch the lock lever with fingers or hook on
it (especially with a fingernail).
Doing so might damage the lock lever.
Doing so might damage the lock lever.
Note
(4)CN25
(4)CN24
(2)CN21
(3)CN22
(3)CN23
Pull out
Pull out
49
(5)
Remove the X-SUS board.
Make sure that you do not to hold the heat sink when removing the Y-SUS board.
2