Sony KE-32TS2E / KE-32TS2U Service Manual ▷ View online

  
 
 
 
                                         
-14-
3.3 Function 
3.3.1 Logic board Function   
(1) Data Processor 
z
  γadjustment (1/2.2/2.4/2.6/2.8) 
z
  NTSC/EBU format(Color matrix)Switch 
z
  RGB gain Control(White balance adjustment、Amplitude limitation) 
z
  Error Diffusion Technology (Grayscale adjustment) 
z
  Dithering (Grayscale adjustment) 
z
  Burn-in Pattern generation 
 
(2) Scan Controller 
z
  Address driver control signal generator (ADM) 
z
  Scan driver control signal generator (SDM) 
z
  X/Y sustain control signal generator 
 
(3) Waveform ROM 
z
  Waveform Pattern for drive / Timing memory 
 
(4) MPU 
z
  Synchronous detection 
z
  System control 
z
  Driving voltage (Va,Vs,Vr,Vw) adjustment and tuning 
z
  Abnormal watching (breakdown detection) / abnormal processing 
z
  Is (sustain) current control (sustain pulse control) 
z
  Ia (address) current control (sub-field control) 
z
  External communication control 
z
  Waveform ROM pattern writing 
             
 
(5) EEPROM 
z
  Control parameter memory 
z
  The accumulation energizing time (Every hour). 
z
  Abnormal status memory (16 careers) 
 
 
 
 
 
 
  
 
 
 
                                         
-15-
 
Setting [hex] 
Sub 
Address 
Data 
bit 
Symbol 
Item 
Function 
RANGE 
INITIAL value
00 
7-0  MAPVER 
address MAP 
Version 
Indicates the version number of the address 
map. 
00 ~ FF 
01【UA1x/6x】
02【UA7x   】
7 ERRF 
update 
of 
Error 
Flag 
Indicates that an error has occurred.   
It can be cleared with the ErrRST setting.   
If this flag is set,   
•  Error code is written. 
•  Cannot enter the PDP-ON mode. 
0: Not updated 
1: Updated 
6 OHRF 
update of 
Operation Hours 
Flag  
Indicates that the drive hours are counted.   
0: Not updated 
1: Updated 
PSDF 
Power Shut 
Down Flag 
Indicates that shutdown of the AC power is 
detected and the PDP has executed the 
OFF-sequence. It can be cleared with the 
PSDRST setting.   
0: Not detected 
1: Detected 
01 
4-0  CNDC 
Condition Code 
Indicates status of the module. 
02 7-0 
ERRC 
 
Error 
Code 
Indicates error code. 
The error codes of as many as 16 errors in 
the past can be retrieved with the ERRS 
setting. 
. Same error code is not stored 
continuously. 
00~FF 00 
03 
7-0  OHRH 
Operation Hours 
Higher bits 
Indicates the higher 8 bits of the module 
driving hours. *1) 
00~FF 
00 
04 
7-0  OHRL 
Operation Hours 
Lower bits 
Indicates the lower 8 bits of the module 
driving hours. *1) 
00~FF 
00 
PATSEL 
Selecting 
patterns 
It selects the built-in test pattern signals of 
this display. This setting is valid when the 
PATON setting is 1. 
0: The single 
color display 
is switched 
every 2 
seconds. A 
total of 8 
colors are 
displayed. 
1: All white 
(Different 
from actual 
white.) 
PATON 
Built-in pattern 
display is set to 
ON.  
Display of the built-in pattern signal in this 
product is turned ON/OFF. 
0: Displaying 
the input 
signal 
1: Displaying 
the built-in 
pattern 
ADEN 
Address 
data 
enable 
The black screen is displayed. 
0 is set when the input video signal has 
disturbance. 
0: Blank 
1: Displaying 
the input 
signal 
Be sure to use the display with the setting 
fixed to 0. 
0~1 
Be sure to use the display with the setting 
fixed to 1. 
0~1 
1【UA1x/6x】
20 
3 DSPPRT 
DiSPlay 
PaRiTy 
Input reflection polarity setting 
0:Emits light by 
LOW 
1:Emits light by 
High 
1【UA7x   】
 
 
 
  
 
 
 
                                         
-16-
2 IFON 
Interface power 
supply ON   
Switches the interface power ON/OFF. 
Use this item when you want turn ON the 
main power of the interface side only when 
the PDPON is set to 0. This setting is 
invalid when PDPON is set to 1. 
0: Power OFF 
1: Power ON 
1 PDPON 
High voltage 
power supply 
ON 
Switches ON/OFF the high voltage power 
supply of PDP. 
0: Power OFF 
1: Power ON 
20 
 
   
Be sure to use the display with the setting 
fixed to 1. 
0~1 
    *1) It is not the one to guarantee brightness. 
Setting[hex] 
Sub 
Address 
Data 
bit 
Symbol 
Item 
Function 
RANGE 
INITIAL value
7-5  - 
Be sure to use the display with the setting 
fixed to 0. 
0~7 
0【UA1x/6x】
7-6  - 
Be sure to use the display with the setting 
fixed to 0. 
0~7 
0【UA7x】 
CCFMD 
Color correction 
mode 
Selecting the color correction modes.   
Valid when the CCFON setting is 1   
0: Luminance 
has priority. 
1: Gradation 
has priority 
3 DCBON 
Dynamic Color 
Balance 
Tracking correction of white balance 
between the high luminance and the low 
luminance.  
0: OFF 
1: ON 
2 HAON 
Heat APC 
function 
When a picture with high luminance/small 
area is displayed for about 3 minutes or 
longer, the number of pulses is reduced to 
about 20% at a maximum. This item can be 
used to reduce panel temperature/extend 
useful life when the display is used to 
show a still image.   
0: OFF 
1: ON 
Be sure to use the display with the setting 
fixed to 0. 
0~1 
21 
0 DSETEN 
Data  
set  
enable 
Whether the register value is reflected to 
the operating status of this product, 
selected by this item.   
The following switch is executed.   
0:  The received register value is reflected 
from the next field.   
1:  The received register value is stored so 
that the DSET setting is reflected from 
the next field.   
(DSET setting: Setting bit 0 of address 
FF) 
0: Invalid 
1: Valid 
CCFON Color 
correction 
Color collection process is turned 
ON/OFF.  
0: OFF 
1: ON 
6 CCFORM  Color correction 
format 
 
Color collection process is switched.   
This item is valid when CCFON setting is 
1.  
0: NTSC 
1: EBU 
22 
5-3  - 
Be sure to use the display with the setting 
fixed to 0. 
0~7 
Sub 
Data  Symbol 
Item 
Function 
Setting [hex] 
Setting [hex] 
Sub 
Address 
Data 
bit 
Symbol 
Item 
Function 
RANGE 
INITIAL value
  
 
 
 
                                         
-17-
Addre
ss 
bit 
 
 
 
RANGE 
INITIAL 
value 
22 2-0 
GAMSEL 
Selecting the 
reverse  γ 
correction 
Reverse  γ  correction level is set.   
The setup 7 is the test mode. Do not select 
the setup 7. 
When the setup 6 is selected, setting of the 
addressed in the range of 31~51 become 
valid.  
0: OFF 
1:  1.0 th power
 
2: 2.2 nd 
power 
3:  2.4 th power 
4:  2.6 th power 
5:  2.8 th power 
6: USER 
7: TEST 
23 7-0 
CONTRAS
Peak luminance 
Peak luminance is adjusted.   
When the display picture load is heavy, the 
peak luminance is automatically limited.   
00~FF FF 
24 
7-0 R-RATIO  R ratio 
00~FF FF 
25 7-0 
G-RATIO 
ratio 
00~FF 
FF 
26 
7-0 B-RATIO  B 
ratio 
White balance is adjusted.     
Use the display with at least one item being 
set to FF (hex). 
00~FF 
FF 
7 IRQRST  Clearing the IRQ 
output signal 
This item implements control to return the 
IRQ signal from "HIGH" to "Low" level 
when an error occurs. When this item is set 
to 1, the IRQ signal is returned to "Low" 
level. 
0: Normal 
1: IRQ signal 
clear  
6 ERRRST  Clearing the 
ERRF flag   
This item implements control to return the 
ERRF flag to 0 when an error occurs.   
When this item is set to 1, this setting 
automatically returns to 0 after returning 
the ERRF flag to 0. 
0: Normal 
1: ERRF 
flag clear 
Be sure to use the display with the setting 
fixed to 0. 
0~1 0【UA1x/6x】
OHRRST 
 
 
Clearing the 
OHRF flag 
The control by which the OHRF flag is 
returned to 0 is done. This setting 
automatically returns to the state of 0 after 
returning 0 the ERRF flag when this 
setting is set to one. 
0: Normal 
1: OHRF 
flag clear 
0【UA7x】
PSDRST 
Clearing the 
PSDF flag 
This item exercise control to return the 
PSDF flag to 0 when this machine 
performs the OFF sequence at AC power 
shutdown. When this item is set to 1, this 
setting automatically returns to 0 after 
returning the PSDF flag to 0.   
0: Normal 
1: PSDF 
flag 
clear 
27 
3-0 ERRS 
Error 
code 
selection 
When this setting is changed and the 
ERRC setting is read out, the error 
contents (as many as 16 errors) of the 
module that have occurred in the past can 
be checked.   
If more than 16 errors have occurred, the 
error code is updated starting from the 
oldest error.   
0: Latest error 
1: Previous 
error 
2:  
|   
E:  
F:Oldest error 
7-6 
Be sure to use the display with the setting 
fixed to 0. 
0~3 0【UA1x/6x】
28 
 
 
PWMP 
Power Maximam 
peek control 
The PWMAX setting is switched to 
constant brightness (peak electric power) 
control. The password setting is necessary 
to turn on this setting. 
When password 
is set 
0:OFF  1:ON 
0【UA7x】
Sub 
Data  Symbol 
Item 
Function 
Setting [hex] 
Page of 79
Display