– 13 –
KDS-R50XBR1/R60XBR1
RM-Y914
RM-Y914
SECTION 1
SELF DIAGNOSIS FUNCTION
1. Summary of Self-Diagnosis Function
- This device includes a self-diagnosis function.
- In case of abnormalities, the POWER/STANDBY indicator automatically blinks. It is
possible to predict the abnormality location by the number of blinks. The Instruction
Manual describes blinking of the POWER/STANDBY indicator.
- If the symptom is not reproduced sometimes in case of a malfunction, there is recording of
whether a malfunction was generated or not. Operate the remote command to confirm the
matter on the screen and to predict the location of the abnormality.
2. Diagnosis Items and Prediction of Malfunction Location
- When a malfunction occurs the POWER/STANDBY indicator only blinks for one of the
following diagnosis items. In case of two or more malfunctions, the item which first
occurred blinks. If the malfunctions occurred simultaneously, the item with the lower
blink count blinks first.
- The screen display displays the results regarding all the diagnosis items listed below.
The display "0" means that no malfunctions occurred.
Defected symptoms
La
Temp error
mp cover error
3 times
2 times
- L
- Set temperture is high.
- Temp sensor connector 
  is not attached securely.
  
(CN7100 on S1 board,
 
 CN7120 on S2 board)
-Lamp is not set securely.
amp cover is not
attached securely.
Diagnosis Item
Number of times
POWER/STANDBY
indicator blinks
Probable Cause
Location
Lamp driver error
5 times
- Lamp driver is faulty.
- No picture/No sound
Low B error
6 times
- B_12V is not supplie
(GT board)
d.
- No picture/No sound
- Lamp for the light
source burns out.
- No picture/No sound
- No picture/No sound
- Short-circuit of Audio power
supply line.
-Blow out of fuse.
(PS3001 on K board)
-IC failure.
(IC3005 on K board)
D-
ATSC OVP
OVP error
8
10 times
times
-B -12V is over voltage.
(B board)
-Q_10.5V is over voltage.
(GT board)
- No picture/No sound
Fan stopped
4 times
- F an 1-4 power is not
supplied. (
ASU board
)
- F
-Fan caught wires or 
harnesses.
an connector is not
attached securely.
- No picture/No sound
Lamp error
LAMP-LED flashes
- No picture/No sound
Audio error
7 times
- No picture/No sound
- No picture/No sound
– 14 –
KDS-R50XBR1/R60XBR1
RM-Y914
RM-Y914
3. Blinking count display of POWER/STANDBY indicator
- One blink is not used for self-diagnosis.
- Example
Diagnosis item
LED blinks
Lamp cover
3 times
Fan
4 times
LED ON : 0.3sec
LED OFF : 0.3sec
- Release of POWER/STANDBY indicator blinking
The POWER/STANDBY indicator blinking display is released by removing the plug from
the power or leaving for 2 minutes.
4. Self-diagnosis screen displays
- In cases of malfunctions where it is not possible to determine the symptom such as when
the power goes off occasionally or when the screen disappears occasionally, there is a
screen display on whether the malfunction occurred or not in the past (and whether the
detection circuit operated or not) in order to allow confirmation.
<Screen Display Method>
- Quickly press the remote command button in the following order from the standby state.
Channel
Vol
Be aware that this differs from
the method of entering the
service mode (Vol +).
LED OFF
3.0sec
DISPLAY
5
-
POWER
1
: LAMP_ERROR
0
 2
: TEMP_ERROR
0
 2
: LAMP_TEMP
0
3
: LAMP_COVER
0
4
: FAN_ERROR
0
5
: LAMP_DRIVER
1
6
: LOWB_ERROR
0
7
: AUDIO_PROT
0
8
: D_OVP
0
10 : ATSC_OVP
0
SELF CHECK
- Numeral "1" means a fault was detected one time
- Numeral "0" means that no fault was detected
POWER/STANDBY
POWER
LAMP
TIMER
STD/DUO
Indicators
– 15 –
KDS-R50XBR1/R60XBR1
RM-Y914
RM-Y914
- The results display is not automatically cleared. In case of repairs and after repairs, check
the self-diagnosis screen and be sure to return the results display to "0".
- If the results display is not returned to "0" it will not be possible to judge a new malfunction
after completing repairs.
<Method of Clearing Results Display>
1. Power off (Set to the standby mode)
2.
Channel
Vol
3. Channel
<Method of Ending Self-Diagnosis Screen>
- When ending the self-diagnosis screen completely, turn the power switch OFF on the
remote commander or the main unit.
5. Self-Diagnosis function operation
8
ENTER
DISPLAY
5
-
POWER
2
:
Temp 
When the temperature sensor (for Ambient) on the S1 board detects high 
temperature or the temperature sensor (for Lamp) on the S2 board detects
high temperature or the temperature sensor (for Panel) on the C board detects
high temperature, the DE-micro (IC5) turns off the lamp.
 
3
:
Lamp cover
The rib at the back of the lamp cover closes the SW on the T1 board. The lamp 
closes the SW on the T2 board.
It is monitored by DE-micro (pin63 of IC5) and turned off the lamp when it is
opened.
4
:
Fan 
Fan rotation is detected by ‘‘FAN-PROT” and the DE-micro (pin92 of IC5) turns
off the lamp when it is ‘‘high”.
5
:
Lamp Driver
When the ‘‘LAMP-PROT” (pin83 of IC5) is high, the lamp is not turned on.
If the  ‘‘LAMP-HV-DET” (pin94 of IC5) is low at the same time, it classified as
no high voltage of the lamp driver.
6
:
Low B error
When no ‘‘D5V (SW_5V)”  is detected, pin 129 of TV-micro (IC7002) is low and
 it turns off the main power. (for example, blowout of thermal fuse).
7
:
Audio
When DC voltage is detected at the speaker output, ‘‘SP-PROT” (pin102  of IC5) 
is low and it turns off the main power.
8
:
D-OVP
Be not in use.
 9
:
Panel error
When there is not ack from the temperature sensor on the S1, S2 and C board or 
IIC line connector (CN2303: ASU board, CN7956: DSU board, CN6901: C board)
is not seated securely. it is monitored by DE-micro.
10
:  ATSC-OVP
Be not in use.
LAMP
:
Lamp
When the ‘‘LAMP-PROT” (pin83 of IC5) is high, the lamp is not turned on.  
If the ‘‘LAMP-HV-DET” (pin94 of IC5) is high at the same time, it classified  
as no lamp or a dead lamp.
– 16 –
KDS-R50XBR1/R60XBR1
RM-Y914
RM-Y914
SECTION 2
DISASSEMBLY
Photo: KDS-R50XBR1
2-1. REAR COVER
3
2
2
1
Loosen screw
Lamp door assembly
Rear cover
4
4
Page of 127