Sony KDL-70X4500 (serv.man3) Service Manual ▷ View online
KDL-70X4500 (K) 2-4
2-2-2. SET REBOOTS
TV micro (on AU board) is monitoring if BE Micro & EMMA (on FBU board) are alive
or on abnormal status by watch dog timer. When BEM or EMMA has not boot up, TVM
try to re-start. We can see chassis reboot at this case. Check whether FBU board is
supplied with correct power or not.
or on abnormal status by watch dog timer. When BEM or EMMA has not boot up, TVM
try to re-start. We can see chassis reboot at this case. Check whether FBU board is
supplied with correct power or not.
- FBU board
- CN4002 12V power and harness to G8 board.
- F2800, F4100, F4101, F4102, F5400, F7800, F7801 conduction.
- CN4002 12V power and harness to G8 board.
- F2800, F4100, F4101, F4102, F5400, F7800, F7801 conduction.
If power rail has no problem, replace FBU board.
2-2-3. SELF DIAGNOSIS
2-2-3-1. RED LED BLINKS TABLE
When self diagnosis happens, STBY (RED) LED blinks and
the history can be seen on display by self diagnosis mode.
the history can be seen on display by self diagnosis mode.
Power Error (watching 12V rail)
T-CON Error
[CCFL] Panel Inverter Error
[CCFL] Panel Inverter Error
[LED] GL board Error
Panel Temperature Abnormal Detection
Audio Abnormal Detection
FAN Error -> Not detect (reboot operation)
[CCFL] Panel Balancer Error
[LED-BL] SPI Error (Babylon Communication Error)
[LED-BL] SPI Error (Babylon Communication Error)
Contents
Display
(Self Diagnosis mode )
Red LED Blink
POW_ERR1
T_CON
BACKLITE
PANELTEMP
AUD_PROT
FAN_ERR
BALANCER
2
5
6
7
8
9
13
KDL-70X4500 (K) 2-5
2-2-3-2. RED LED BLINKS (Chart C)
NO
2 times
YES
See
1) Power Error
1) Power Error
RED LED Blinks
NO
9 times
YES
See
6) FAN Error
6) FAN Error
NO
NO
YES
7 times
YES
See
4) TEMP Error
4) TEMP Error
6 times
See
3) BACK LIGHT Error
3) BACK LIGHT Error
NO
8 times
YES
See
5) AUDIO Error
5) AUDIO Error
13 times
YES
See
7) Balancer Error
7) Balancer Error
NO
5 times
YES
See
2) T-CON Error
2) T-CON Error
KDL-70X4500 (K) 2-6
1) Power Error (R ED 2 tim es blink )
This indicates POWER Error, Low B error of 12V from G8 board. TV Micro (on AU board)
monitors pin79 and pin138 to detect POWER_ERR and shuts down chassis power to
Standby status.
monitors pin79 and pin138 to detect POWER_ERR and shuts down chassis power to
Standby status.
TV Micro pin138 Normal condition : Low / Error case : High
TV Micro pin79 i_lb_err< 0.7V(PW_ERR_LEV)
TV Micro pin79 i_lb_err< 0.7V(PW_ERR_LEV)
- Check 12V at CN 1000 on AU board. And F1001 on AU has 12V or not.
- Check G8 board.
- Check G8 board.
2) T-CON Error (R ED 5 tim es blink )
This indicates T-CON RDY signal error from timing controller of Panel module.
BE micro pin128 on FBU board detects it.
BE micro pin128 on FBU board detects it.
BE Micro pin128 Normal condition : High / Error case : Low
Replace Panel module.
3) B ack Light Error (R ED 6 tim es blink )
This indicates panel power circuit error such as inverter.
BE micro pin 78 on FBU board detects it.
BE micro pin 78 on FBU board detects it.
BE Micro pin 78 Normal condition : High / Error case : Low
KDL-70X4500 (K) 2-7
4) Tem p Error (R ED 7 tim es blink )
This indicates high temperature inside chassis. IC1000 on AU board Side is monitoring
temperature. IC1000 is controlled by BEM I2C.
temperature. IC1000 is controlled by BEM I2C.
When it happens;
- Check chassis environment.
- Check around IC1000 and replace AU board if temperature monitoring circuit has problem.
- Check chassis environment.
- Check around IC1000 and replace AU board if temperature monitoring circuit has problem.
5) Audio Error (R ED 8 tim es blink )
This indicates Audio Error. (Protection)
It happens;
- Error of Speakers and Harness.
- Error of Speakers and Harness.
Check Voltage at CN1002 20pin on AU board. ( Low = Normal , High= Error)
- Low Voltage at IC1800 [ Audio_Vcc(=12V) , A9V , D3.3V ]
- Error of IC1800
- Error of IC1800
Replace AU board.
.
.
Click on the first or last page to see other KDL-70X4500 (serv.man3) service manuals if exist.