DOWNLOAD Sony KDL-70X4500 (serv.man3) Service Manual ↓ Size: 2.62 MB | Pages: 36 in PDF or view online for FREE

Model
KDL-70X4500 (serv.man3)
Pages
36
Size
2.62 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
kdl-70x4500-sm3.pdf
Date

Sony KDL-70X4500 (serv.man3) Service Manual ▷ View online

KDL-70X4500 (K)     2-4
2-2-2. SET REBOOTS
TV micro (on AU board) is monitoring if BE Micro & EMMA (on FBU board) are alive
or on abnormal status by watch dog timer. When BEM or EMMA has not boot up, TVM
try to re-start. We can see chassis reboot at this case. Check whether FBU board is
supplied with correct power or not.
- FBU board
   - CN4002 12V power and harness to G8 board.
   - F2800, F4100, F4101, F4102, F5400, F7800, F7801  conduction.
If power rail has no problem, replace FBU board.
2-2-3. SELF DIAGNOSIS
2-2-3-1. RED LED BLINKS TABLE
When self diagnosis happens, STBY (RED) LED blinks and
the history can be seen on display by self diagnosis mode.
Power Error (watching 12V rail)   
T-CON Error
[CCFL] Panel Inverter Error
[LED] GL board Error
Panel Temperature Abnormal Detection
Audio Abnormal Detection
FAN Error -> Not detect (reboot operation)
[CCFL] Panel Balancer Error
[LED-BL] SPI Error (Babylon Communication Error)
Contents
Display
(Self Diagnosis mode )
Red LED Blink 
POW_ERR1
T_CON
BACKLITE
PANELTEMP
AUD_PROT
FAN_ERR
BALANCER
2
5
6
7
8
9
13
KDL-70X4500 (K)     2-5
2-2-3-2. RED LED BLINKS (Chart C)
NO
2 times
YES
See  
1) Power Error
RED LED Blinks
NO
9 times
YES
See  
6) FAN Error
NO
NO
YES
7 times
YES
See  
4) TEMP Error
6 times
See  
3) BACK LIGHT Error
NO
8 times
YES
See  
5) AUDIO Error
13 times
YES
See  
7) Balancer Error
NO
5 times
YES
See  
2) T-CON Error
KDL-70X4500 (K)     2-6
1) Power Error (R ED 2 tim es blink )
This indicates POWER Error, Low B error of 12V from G8 board. TV Micro (on AU board)
monitors pin79 and pin138 to detect POWER_ERR and shuts down chassis power to 
Standby status.
TV Micro pin138      Normal condition : Low  /   Error case : High
TV Micro pin79        i_lb_err< 0.7V(PW_ERR_LEV)
   - Check 12V at CN 1000 on AU board. And F1001 on AU has 12V or not.
   - Check G8 board.
2) T-CON  Error (R ED 5 tim es blink )
This indicates T-CON RDY signal error from timing controller of Panel module.
BE micro pin128 on FBU board detects it.
BE Micro pin128   Normal condition : High  /   Error case : Low
Replace Panel module.
3) B ack  Light Error (R ED 6 tim es blink )
This indicates panel power circuit error such as inverter.
BE micro pin 78 on FBU board detects it.
BE Micro pin 78   Normal condition : High  /   Error case : Low
KDL-70X4500 (K)     2-7
4) Tem p Error (R ED 7 tim es blink )
This indicates high temperature inside chassis. IC1000 on AU board Side is monitoring
temperature. IC1000 is controlled by BEM I2C.
When it happens;
   - Check chassis environment.
   - Check around IC1000 and replace AU board if temperature monitoring circuit has problem.
5) Audio Error (R ED 8 tim es blink )
This indicates Audio Error. (Protection)
 It happens;
   - Error of  Speakers and Harness.
Check Voltage at CN1002 20pin on AU board. ( Low = Normal , High= Error)
   - Low Voltage at IC1800 [ Audio_Vcc(=12V) , A9V , D3.3V ]
   - Error of IC1800
Replace AU board.
.
 .
Page of 36
Display

Click on the first or last page to see other KDL-70X4500 (serv.man3) service manuals if exist.