Sony KDL-65W5100 Service Manual ▷ View online
21
KDL-65W5100
KDL-65W5100
2-4. SETTING THE DESTINATION AFTER
REPLACING THE BU BOARD
By default, the data value set for the Destination information on the
replacement BU Board is set to 3 for US and Canada models. To
change the destination to 17 for Mexico and Latin America models,
use the following steps:
replacement BU Board is set to 3 for US and Canada models. To
change the destination to 17 for Mexico and Latin America models,
use the following steps:
1. Access Service Mode.
Press the following buttons on the Remote Commander within a
second of each other:
second of each other:
DISPLAY
Channel
5
Volume
+
POWER .
QM
0 0 SERVICE
INFO
DTV
PACKAGE:
MAIN MICRO
SUB MICRO
aa0048pn
PROGRAM:
BOOT:
USER DATA:
SERVICE DATA:
AUDIO PACK DATA:
VIDEO PACK DATA:
BOOT:
USER DATA:
SERVICE DATA:
AUDIO PACK DATA:
VIDEO PACK DATA:
PROGRAM:
BOOT:
DATA:
BOOT:
DATA:
DM1.00A.1000
DB1.002W(REL)
DU1.003A
DS1.003A
DA1.000D
DV1.001A
DB1.002W(REL)
DU1.003A
DS1.003A
DA1.000D
DV1.001A
SM1.001W00AA
SB0.011W00AA
SD0.041W00AA
SB0.011W00AA
SD0.041W00AA
SOFTWARE VERSION
Digital Service Menu
2. To display the Chassis menu, press JUMP on the Remote
Commander.
SUB
SERVICE
000
MODEL
000
DESTINATION 3
Default Destination is set
for US/CND models
for US/CND models
3. For Mexico and Latin America models only, press Channel 3 until the
data value of the DESTINATION is set to 17.
SUB
SERVICE
000
MODEL
000
DESTINATION 17
For Mexico and Latin America models,
set the data value to 17
set the data value to 17
CAUTION: Verify the DESTINATION is set to 17 before proceeding
to the next step. If another destination data value is selected, it
may possibly corrupt the software which would require a BU Board
replacement.
to the next step. If another destination data value is selected, it
may possibly corrupt the software which would require a BU Board
replacement.
4. To write the data press MUTE, and then press Channel 0 .
SUB
WRITE
000
MODEL
000
DESTINATION 17
5. To set the data to provide the correct auto programming options,
press Channel 8 , then press MUTE, and then press Channel 0 .
SUB
RST-EXE
000
MODEL
000
DESTINATION 17
6. Go through the initial setup and verify that the South American
regions display.
2-5. RESETTING TO FACTORY DEFAULTS
Use the following instructions to restore the User Controls and
Channel Memory settings to the preset factory conditions.
Channel Memory settings to the preset factory conditions.
1. While holding down the on the Remote Commander, press the
POWER button on the Front Panel of the set.
The set restarts and displays the initial setup screen. This may take
several minutes.
several minutes.
22
KDL-65W5100
KDL-65W5100
SECTION 3: DIAGRAMS
3-1. CIRCUIT BOARDS LOCATION
3-2. PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS INFORMATION
All voltages are in V.
S : Measurement impossibility.
: B+line.
: B-line. (Actual measured value may be different).
: signal path. (RF)
Circled numbers are waveform references.
The components identifi ed by shading and
!
symbol are critical for safety. Replace
only with part number specifi ed.
The symbol
indicates a fast operating fuse and is displayed on the component
side of the board. Replace only with fuse of the same rating as marked.
Les composants identifi es per un trame et une marque
!
sont critiques pour la
securite. Ne les remplacer que par une piece portant le numero specifi e.
Le symbole
indique une fusible a action rapide. Doit etre remplace par une
fusible de meme yaleur, comme maque.
NOTE: The components identifi ed by a red outline and a mark contain confi dential
information. Specifi c instructions must be adhered to whenever these components
are repaired and/or replaced.
See Appendix A: Encryption Key Components in the back of this manual.
information. Specifi c instructions must be adhered to whenever these components
are repaired and/or replaced.
See Appendix A: Encryption Key Components in the back of this manual.
All capacitors are in μF unless otherwise noted. pF : μμF 50WV or
less are not indicated except for electrolytics and tantalums.
less are not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise specifi ed.
All resistors are in ohms. k
Ω=1000Ω, MΩ=1000kΩ
Indication of resistance, which does not have one for rating
electrical power, is as follows:
electrical power, is as follows:
Pitch : 5mm
Rating
electrical
power
:
1
/
4
W
1
/
4
W in resistance,
1
/
10
W and
1
/
16
W in chip resistance.
: nonfl ammable resistor
: fusible resistor
: internal component
: panel designation and adjustment for repair
: earth ground
: earth-chassis
All variable and adjustable resistors have characteristic curve B,
unless otherwise noted.
unless otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10M
Ω digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production
tolerances.
tolerances.
G8
BH2
BU
SWITCH UNIT
HL1M
HSN
23
KDL-65W5100
KDL-65W5100
G
D
S
B1 E1
C2
B2 C1
E2
2
3
4
5
6
7
8
9
–
1
G
D
S
B2 E2
C1
B1 C2
E1
B2 E2
C1
B1 C2
E1
B2 E2
C1
B1 C2
E1
B1 E1
E2
C1(B2)
C2
B1
E2
C1
C2
(B2)
E1
(B2)
E1
E2
B1
C2
C1
B1
E1
C2
B2
C1
E2
G
S
S
D
G
D
B1
E1
C2
B2
C1
E2
B1
E2
C2
C1(B2)
E2
B1
C1
C2
E1(B2)
C2
B1
C1
E2
E1(B2)
C2
B1
C1
E2
B2
E1
C2
Ver.1.6
Transistor
(FET)
(FET)
Transistor
Transistor
Transistor
Transistor
Transistor
Transistor
Transistor
Transistor
Transistor
Discrete semiconductor
(Chip semiconductors that are not actually used are included.)
Diode
Diode
Diode
Diode
Diode
Diode
Diode
Diode
Diode
Diode
Source
Source
Anode
Anode
(NC)
(NC)
Cathode
Anode
Cathode
Common
Cathode
Cathode
Common
Cathode
Cathode
Common
Common
Common
Common
Cathode
Anode
Base
Emitter
Collector
Base
Emitter
Collector
Drain
Gate
Gate
Drain
Device
Printed symbol
Terminal name
Circuit
Terminal name of semiconductors in silk screen
printed circuit ( )
Anode
Anode
Anode
Cathode
Anode
Anode
Cathode
Transistor
(FET)
(FET)
Transistor
(FET)
(FET)
Emitter
Collector
Base
Transistor
Source
Gate
Drain
Cathode
Anode
Anode
Cathode
Anode
Anode
*
18
11
17
16
15
14
13
12
10
21
20
19
23
22
REFERENCE INFORMATION
RESISTOR
: RN
: RN
METAL FILM
: RC
SOLID
: FPRD NONFLAMMABLE CARBON
: FUSE NONFLAMMABLE FUSIBLE
: RW
: FUSE NONFLAMMABLE FUSIBLE
: RW
NONFLAMMABLE WIREWOUND
: RS
NONFLAMMABLE METAL OXIDE
: RB
NONFLAMMABLE CEMENT
: ADJUSTMENT
RESISTOR
COIL
: LF-8L MICRO INDUCTOR
: LF-8L MICRO INDUCTOR
CAPACITOR
: TA
: TA
TANTALUM
: PS
STYROL
: PP
POLYPROPYLENE
: PT
MYLAR
: MPS
METALIZED POLYESTER
: MPP
METALIZED POLYPROPYLENE
: ALB
BIPOLAR
: ALT
HIGH TEMPERATURE
: ALR
HIGH RIPPLE
Click on the first or last page to see other KDL-65W5100 service manuals if exist.