Sony KDL-55X4500 Service Manual ▷ View online

KDL-55X4500 (CH)     3
Design and specifications are subject to change without notice.
PC input signal reference chart for       pc (PC) and HDMI        (HDMI IN) 1, 2, 3, 4 
***
This TV’s PC input does not support Sync on Green or Composite Sync.
This TV’s PC input does not support interlaced signals.
For the best picture quality, it is recommended to use the signals in the above chart with a 60 Hz vertical 
frequency (boldfaced).
Product usage condition
Display Spec
View angle ( L
0
/3)*
Horizontal      85
° Vertical      80°
Definition 
(TV Line)*
analog RF
Horizontal      350, Vertical      400 TVL**
SDTV
Horizontal      450, Vertical      450 TVL**
Color gamut*
Smearing time of motion picture*
20 ms **
Audio characteristic* 
Sound pressure THD in rated input      10%**
*
**
Resolution
Horizontal
frequency (kHz)
Vertical
frequency (Hz) 
Standard
Signals
Horizontal
(Pixel) 
×
Vertical
(Line)
VGA
640
×
480
31.5
60
VGA
640
×
480
37.5
75
VESA
720
×
400
31.5
70
VGA-T
SVGA
800
×
600
37.9
60
VESA Guidelines
 
800
×
600
46.9
75
VESA
XGA
1024
×
768
48.4
60
VESA Guidelines
 
1024
×
768
56.5
70
VESA
1024
×
768
60.0
75
VESA
WXGA
1280
×
768
47.4
60
VESA
1280
×
768
47.8
60
VESA
1280
×
768
60.3
75
1360
×
768
47.7
60
VESA
SXGA
1280
×
1024
64.0
60
VESA
HDTV
1920
×
1080
67.5
60
CEA-861***
Model name
KDL-55X4500
Humidity
20% - 80%
Air Pressure
86 kPa - 106 kPa
Luminance*
350 cd/m
2
**
Contrast*
150:1 **
HDTV
Horizontal      720, Vertical      720 TVL**
32 % **
Refer to SJ/T11348-2006 <Methods of measurement for digital television flat panel displays> .
These values are required by SJ/T11343-2006 <General specification for digital television LCD displays> in normal
temperature.  
This affects the “                          (Video Settings)” menu and “                  (Screen)” menu settings. 
To view PC contents, set “                            (Game/Text Mode)” to “     (On)”, “                  (Wide Mode)” 
to “16:9                  (Full)”, and “                 (Display Area)” to “             (Full Pixel)”.
1080p timing when applied to the HDMI input will be treated as a video timing and not a PC timing.
Environment Temperature
5
°C - 35°C
KDL-55X4500 (CH)     4
CAUTION
These servicing instructions are for use by qualified service
personnel only.
To reduce the risk of electric shock, do not perform any servicing
other than that contained in the operating instructions unless you
are qualified to do so.
WARNING!!
An isolation transformer should be used during any service to
avoid possible shock hazard, because of live chassis.
The chassis of this receiver is directly connected to the ac power
line.
!
 
SAFETY-RELATED COMPONENT
WARNING!!
Replace all components with Sony parts whose part numbers
appear as shown in this manual or in supplements
published by Sony.
WARNINGS AND CAUTIONS
SAFETY-RELATED COMPONENT
WARNING
It is essential that all critical parts be replaced only with the part
number specified in the electrical parts list to prevent electric
shock, fire, or other hazard.
NOTE: Do  not modify the original design without obtaining
written permission from the manufacturer or you will
void the original parts and labor guarantee.
USE CAUTION WHEN HANDLING THE LCD PANEL
When repairing the LCD panel, be sure you are grounded by
using a wrist band.
When repairing the LCD panel on the wall, the LCD panel must
be secured using the 4 mounting holes on the rear cover.
1) Do not press on the panel or frame edge to avoid the risk of
electric shock.
2) Do not scratch or press on the panel with any sharp objects.
3) Do not leave the module in high temperatures or in areas of
high humidity for an extended period of time.
4) Do not expose the LCD panel to direct sunlight.
5) Avoid contact with water. It may cause a short circuit within
the module.
6) Disconnect the AC power when replacing the backlight (CCFL)
or inverter circuit.
(High voltage occurs at the inverter circuit at 650Vrms.)
7) Always clean the LCD panel with a soft cloth material.
8) Use care when handling the wires or connectors of the inverter
circuit. Damaging the wires may cause a short.
9) Protect the panel from ESD to avoid damaging the electronic
circuit (C-MOS).
KDL-55X4500 (CH)     5
SAFETY CHECK-OUT
After correcting the original service problem, perform the
following safety checks before releasing the set to the customer:
1. Check the area of your repair for unsoldered or poorly
soldered connections. Check the entire board surface for
solder splashes and bridges.
2. Check the interboard wiring to ensure that no wires are
“pinched” or touching high-wattage resistors.
3. Check that all control knobs, shields, covers, ground straps,
and mounting hardware have been replaced. Be absolutely
certain that you have replaced all the insulators.
4. Look for unauthorized replacement parts, particularly
transistors, that were installed during a previous repair. Point
them out to the customer and recommend their replacement.
5. Look for parts which, though functioning, show obvious
signs of deterioration. Point them out to the customer and
recommend their replacement.
6. Check the line cords for cracks and abrasion. Recommend
the replacement of any such line cord to the customer.
7. Check the antenna terminals, metal trim, “metallized”
knobs, screws, and all other exposed metal parts for AC
leakage. Check leakage as described below.
Leakage Test
The AC leakage from any exposed metal part to earth ground
and from all exposed metal parts to any exposed metal part
having a return to chassis, must not exceed 0.5 mA (500
microamperes).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or
RCA WT-540A. Follow the manufacturers’ instructions to
use these instructions.
2. A battery-operated AC milliampmeter. The Data Precision
245 digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The “limit”
indication is 0.75 V, so analog meters must have an accurate
low voltage scale.
The Simpson’s 250 and Sanwa SH-63TRD are examples of
passive VOMs that are suitable. Nearly all battery-operated
digital multimeters that have a 2 VAC range are suitable (see
Figure A).
How to Find a Good Earth Ground
A cold-water pipe is a guaranteed earth ground; the cover-plate
retaining screw on most AC outlet boxes is also at earth ground.
If the retaining screw is to be used as your earth ground, verify
that it is at ground by measuring the resistance between it and a
cold-water pipe with an ohmmeter. The reading should be zero
ohms.
If a cold-water pipe is not accessible, connect a 60- to 100-watt
trouble- light (not a neon lamp) between the hot side of the
receptacle and the retaining screw. Try both slots, if necessary,
to locate the hot side on the line; the lamp should light at normal
brilliance if the screw is at ground potential (see Figure B).
To  Exposed Metal
Parts on Set
0.15 
µ
F
Earth Ground
AC
Voltmeter
o
o
(0.75V)
Trouble Light
AC Outlet Box
Ohmmeter
Cold-water Pipe
FigureA. Using an AC voltmeter to check AC leakage.  
Figure B. Checking for earth ground.
KDL-55X4500 (CH)     6
SELF DIAGNOSIS FUNCTION
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY LED will automatically begin to flash.
The number of times the LED flashes translates to a probable source of the problem.
A definition of the STANDBY LED flash indicators is listed in the instruction manual for the user’s knowledge and reference.
If an error symptom cannot be reproduced, the remote commander can be used to review the failure occurrence data stored in memory to
reveal past problems and how often these problems occur.
DIAGNOSTIC TEST INDICATORS
When an error occurs, the STANDBY LED will flash a set number of times to indicate the possible cause of the problem.
If there is more than one error, the LED will identify the first of the problem areas.
Result for all of the following diagnostic items are displayed on screen.
If the screen displays a “0”, no error has occurred .
Number of times STANDBY
Monitoring Items
Detection
LED (Red) flashes
(Screen Display)
2 times
POW_ERR1
AAS Board IC2104
79pin:  i_lb_err (AD port) < PW_ERR_LEV (Threshold Value)
and
138pin: i_ac_off_det: HIGH
5 times
T_CON
FBA Board IC
5501
1
128Pin: TCON_RDY: Low
or
2
Detected Error of Cayenne Register
6 times
BACKLITE
FBA Board IC
5501
78Pin: INV_FAIL: LOW
7 times
PANLTEMP
FBA Board IC
5501
IIC_ch2 setting value (BEM data)
8 times
AUD_PROT
AAS Board IC2104
19pin: i_au_prot: Low
9 times
FAN_ERR
FBA Board IC
5501
pin154: FAN_ERR: High
13 times
BALANCER
FBA Board IC
5501
1
163pin: BALANCER_ERR: LOW
or
2
SPI_ERR_CNT (SetSREG) >= SPI_ERR_LIM (FactSREG)
DISPLAY OF STANDBY LIGHT FLASH COUNT
STOPPING THE STANDBY FLASH
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY LED for flashing.
STANDBY 
LED
2 sec
Page of 42
Display

Sony KDL-55X4500 Service Manual ▷ Download

  • DOWNLOAD Sony KDL-55X4500 Service Manual ↓ Size: 2.98 MB | Pages: 42 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sony KDL-55X4500 in PDF for free, which will help you to disassemble, recover, fix and repair Sony KDL-55X4500 TV. Information contained in Sony KDL-55X4500 Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.