KDL-55/65HX950,953,955(AEP) 
13 
Fig.11 
Fig.12 
WARNINGS AND CAUTIONS 
9. Tape the plastic bag on the back of panel to protect the panel surface. (Fig.11)   
10. Confirm the orientation of the panel again. The T-CON board side must be at the lower end.  
11. Repack the panel in the original cardboard box. (Fig.12) 
KDL-55/65HX950,953,955(AEP) 
14 
SAFETY CHECK-OUT 
After correcting the original service problem, perform the following safety checks before releasing the set to the customer: 
1. Check the area of your repair for unsoldered or poorly soldered connections. Check the entire board surface for solder splashes and bridges. 
2. Check the interboard wiring to ensure that no wires are “pinched” or touching high-wattage resistors. 
3. Check that all control knobs, shields, covers, ground straps, and mounting hardware have been replaced. Be absolutely certain that you have replaced all the insulators. 
4. Look for unauthorized replacement parts, particularly transistors, that were installed during a previous repair. Point them out to the customer and recommend their replacement. 
5. Look for parts which, though functioning, show obvious signs of deterioration. Point them out to the customer and recommend their replacement. 
6. Check the line cords for cracks and abrasion. Recommend the replacement of any such line cord to the customer. 
7. Check the antenna terminals, metal trim, “metallized” knobs, screws, and all other exposed metal parts for AC leakage. Check leakage as described below. 
8. For safety reasons, repairing the Power board and/or Inverter board is prohibited. 
KDL-55/65HX950,953,955(AEP) 
15 
SAFETY CHECK-OUT 
Leakage Test 
The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed 
metal part having a return to chassis, must not exceed 0.5 mA (500 microamperes). 
Leakage current can be measured by any one of three methods. 
  
1. A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturers’ 
instructions to use these instructions. 
2. A battery-
operated AC milliampmeter. The Data Precision 245 digital multimeter is suitable for this job. 
3. Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The 
“limit” indication is 0.75 V, so analog meters must have an accurate low voltage scale. 
The Simpson’s 250 and Sanwa SH-63TRD are examples of passive VOMs that are suitable. Nearly all 
battery-
operated digital multimeters that have a 2 VAC range are suitable (see Figure A). 
 
 
 
 
How to Find a Good Earth Ground 
A cold-
water pipe is a guaranteed earth ground; the cover-plate retaining screw on most AC outlet boxes is also 
at earth ground. 
If the retaining screw is to be used as your earth ground, verify that it is at ground by measuring the resistance 
between it and a cold-water pipe with an ohmmeter. The reading should be zero ohms. 
If a cold-water pipe is not accessible, connect a 60- to 100-watt trouble- 
light (not a neon lamp) between the hot 
side of the receptacle and the retaining screw. Try both slots, if necessary, to locate the hot side on the line; the 
lamp should light at normal brilliance if the screw is at ground potential (see Figure B). 
KDL-55/65HX950,953,955(AEP) 
16 
SELF DIAGNOSIS FUNCTION 
DIAGNOSTIC TEST INDICATORS 
When an error occurs, the STANDBY LED will flash a set number of times to 
indicate the possible cause of the problem. 
If there is more than one error, the LED will identify the first of the problem areas. 
Result for all of the following diagnostic items are displayed on screen. 
If the screen displays a “0”, no error has occurred . 
The units in this manual contain a self-
diagnostic function. If an error occurs, the STANDBY LED will automatically begin to flash. 
The number of times the LED flashes translates to a probable source of the problem. 
A definition of the STANDBY LED flash indicators is listed in the instruction manual for the user’s knowledge and reference. 
If an error symptom cannot be reproduced, the remote commander can be used to review the failure occurrence data stored in memory to reveal past problems and how often these 
problems occur. 
0.5 
0.5 
DISPLAY OF STANDBY LED FLASH COUNT 
SELF-DIAGNOSTIC SCREEN DISPLAY 
For errors with symptoms such as “power sometimes shuts off” or “screen sometimes goes out” that cannot be confirmed, it is possible to bring up past occurrences of failure for 
confirmation on the screen: 
 
[To Bring Up Screen Test] 
In standby mode, press buttons on the remote commander sequentially in rapid succession as shown below: 
STBY LED
Flash time
Service menu Item
name
(Screeen Display)
Diagnostic Item Description
2
MAIN_POWE
Main 12 V failure
DC_ALERT
Main 5.0/3.3/1.2 V failure
AUD_PROT
Audio amp. Protection
HDMI_EQ
HDMI equalizer/switch I2C NACK
TU_DEMOD
Tuner or demodulator I2C NACK
VLED
LED voltage protection
LD-ERR
LED driver failure
FRC-LED driver SP1 failure
HFR_ERR
FRC device I2C NACK
TCON_ERR
FRC device Initialization failure
PE Micro (PEM) not started
P_ID_ERR
Panel ID NVM Error
6
BACKLITE
Backlight convert OVP
TEMP_ERR
Thermal Error
FAN_ERR
Not used
8
-
Software Error (No Screen Display)
(Also the main board’s memory or Wi-Fi module is a suspect)
9
-
Not used
10
EMIT_ERR
Transmitter board not connected
11
-
Not used
12
-
Not used
3
5
7
4
Page of 118